Eva Melnik

Dr. Eva Melnik

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
FVFlorian Vogelbacher
Florian Vogelbacher
TKTim Kothe
Tim Kothe
PMPaul Muellner
Paul Muellner
EMEva Melnik
Eva Melnik
MSMartin Sagmeister
Martin Sagmeister
RHRainer Hainberger
Rainer Hainberger

10 December 2015 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
EMEva Melnik
Eva Melnik
RBRoman Bruck
Roman Bruck
PMPaul Müellner
Paul Müellner
TSThomas Schlederer
Thomas Schlederer
RHRainer Hainberger
Rainer Hainberger
MLMichael Lämmerhofer
Michael Lämmerhofer

1 November 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
EMEva Melnik
Eva Melnik
PMPaul Muellner
Paul Muellner
GMGiorgio C. Mutinati
Giorgio C. Mutinati
GKGuenther Koppitsch
Guenther Koppitsch
FSFranz Schrank
Franz Schrank
MLMichael Laemmerhofer
Michael Laemmerhofer

9 January 2014 in Chemical Communications
Verified
Journal Article
Open access
PDF file
EMEva Melnik
Eva Melnik
PMPaul Muellner
Paul Muellner
OBOle Bethge
Ole Bethge
EBEmmerich Bertagnolli
Emmerich Bertagnolli
RHRainer Hainberger
Rainer Hainberger
MLMichael Laemmerhofer
Michael Laemmerhofer
Biotin- and iminobiotin-bonded surfaces obtained by thiol–ene chemistry and subsequent modification with polyamines were characterized with respect to streptavidin-binding capacity and reversibility for photonic biosensing using X-ray photoelectron spectroscopy and Mach–Zehnder-interferometric sensors. The streptavidin–iminobiotin system was exploited for reversible multilayer deposition and determination of affinity constants on each layer.

21 August 2023 in IEEE Sensors Letters
Verified
Journal Article
Open access
SKSteffen Kurzhals
Steffen Kurzhals
EMEva Melnik
Eva Melnik
Paulina PlataPaulina Plata
Paulina Plata
ECEsra Cihan
Esra Cihan
PHPeter Herzog
Peter Herzog
RHRainer Hainberger
Rainer Hainberger
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.

14 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
MWMarkus Wellenzohn
Markus Wellenzohn
EMEva Melnik
Eva Melnik
PMPaul Muellner
Paul Muellner
LOLiam O'Faolain
Liam O'Faolain
RHRainer Hainberger
Rainer Hainberger
A two-dimensional photonic crystal defect waveguide sensor based on CMOS-compatible silicon-on-insulator technology was designed for operation in aqueous solutions at a wavelength of 1.34 µm, by the use of the 3D Plane Wave Expansion and the Finite Difference Time Domain simulation method. An operation under water in this wavelength regime allows for a significantly smaller propagation loss in contrast to the state-of-the-art operation wavelength of photonic crystals at 1.55 µm. The sensor working principle is label-free and based on evanescent wave sensing exploiting the local refractive index change induced by the specific binding of target molecules to a capture molecules immobilized on the surface of the phontonic crystal structure. We experimentally proved the theoretical predications of our simulations and demonstrated the sensing functionality of the photonic crystal defect waveguide using the biotin-straptavidin binding system.