Paulina Plata

Ms. Paulina Plata

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in IEEE Sensors Letters
Verified
Journal Article
Open access
SKSteffen Kurzhals
Steffen Kurzhals
EMEva Melnik
Eva Melnik
Paulina PlataPaulina Plata
Paulina Plata
ECEsra Cihan
Esra Cihan
PHPeter Herzog
Peter Herzog
RHRainer Hainberger
Rainer Hainberger
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.

27 February 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
ECEsra Cihan
Esra Cihan
EMEva Melnik
Eva Melnik
SKSteffen Kurzhals
Steffen Kurzhals
Paulina PlataPaulina Plata
Paulina Plata
GMGiorgio Mutinati
Giorgio Mutinati
PLPeter Lieberzeit
Peter Lieberzeit
Third-generation biosensors use enzymes capable of direct electron transfer (DET) to the sensor surface. They are of interest for continuous glucose monitoring in blood or interstitial fluid, but they are rarely investigated. One reason is the hindered DET of the enzymes to the metallic electrodes. In this publication, a novel method for the immobilization of cellobiose dehydrogenase (CDH) DET enzymes employing conductive poly(3,4-ethylenedioxythiophene)-poly (styrene sulfonate) (PEDOT:PSS) inks and a protective polyethylene glycol dimethacrylate (PEG-DMA) hydrogel layer on gold electrodes is reported. This layer stack showed a glucose-specific current response for voltages between −0.2 and 0.4 V in physiological PBS buffer, and enabled interference-less sensing in a solution of acetaminophen, ascorbic acid, dopamine, and uric acid at 0 V. A Michaelis–Menten fit led to a maximum current density (Imax) of 257 ± 7.9 nA/mm2 and a Michaelis–Menten constant (Km) of 28.4 ± 2.2 mM, with a dynamic range of 0.1–20 mM glucose and a limit of detection of 0.1 mM. After 16 h of continuous measurement of 20 mM glucose, the signal decreased to 60% of its initial value. Storage stability was successfully verified until up to 10 days. In summary, this paper shows a simplified approach for the fabrication of third-generation biosensors using CDH-PEDOT:PSS and PEG-DMA hydrogel inks.

20 February 2026 in Sensors and Actuators Reports
Verified
Journal Article
Open access
EMEva Melnik
Eva Melnik
ZCZuzana Chvalova
Zuzana Chvalova
NKNadezhda Kataeva
Nadezhda Kataeva
Paulina PlataPaulina Plata
Paulina Plata
VTVanessa Thoeny
Vanessa Thoeny
RHRainer Hainberger
Rainer Hainberger