Novel printed electronics are projected to grow and be manufactured in the future in large volumes. In many applications, printed electronics are envisaged as sustainable alternatives to conventional (PCB-based) electronics. One such application is in the semi-quantitative drug detection and point-of-care device called ‘GREENSENSE’ that uses paper-based printed electronics. This paper analyses the carbon footprint of GREENSENSE in order to identify and suggest means of mitigating disproportionately high environmental impacts, labeled ‘sustainability hotspots’, from materials and processes used during production which would be relevant in high-volume applications. Firstly, a life cycle model traces the flow of raw materials (such as paper, CNCs, and nanosilver) through the three ‘umbrella’ processes (circuit printing, component mounting, and biofunctionalization) manufacturing different electronic components (the substrate, conductive inks, energy sources, display, etc) that are further assembled into GREENSENSE. Based on the life cycle model, life cycle inventories are modeled that map out the network of material and energy flow throughout the production of GREENSENSE. Finally, from the environmental impact and sustainability hotspot analysis, both crystalline nanocellulose and nanosilver were found to create material hotspots and they should be replaced in favor of lower-impact materials. Process hotspots are created by manual, lab-, and pilot-scale processes with unoptimized material consumption, energy use, and waste generation; automated and industrial-scale manufacturing can mitigate such process hotspots.
We present amperometric sensors based on direct electron transfer enzyme (DET) for the detection of lactate, which is an important medical parameter present in blood and interstitial dermal fluid (ISF). For measurement in blood, we present aplanar screen-printedbiosensor withcarbon working electrodes, whilefor the intendedmeasurement in ISF, we investigated platinum-metallized epoxy microneedle sensors. On both sensor types a bioink was applied, consisting of a DET enzyme mixed with poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). As second layer, a hydrogel layer is deposited to hold the enzyme on site. Local modification of the platinum microneedle sensors was performed by non-contact spotting. The developed modification enables the detection of lactate at a potential of 0 V with response times of 500-700 s. For carbon sensors, a limit of detection of 0.12 mM lactate was determined, and two linear ranges of 0.3-5 mM and 10-50 mM were observed with sensitivities of 319 and 9.6 nA/(mm2·mM), respectively. For locally modified platinum microneedle sensors two linear ranges of 0.3-2.5 mM and 5-30.5 mM were observed with sensitivities of 322.5 and 3.7 nA/(mm 2 ·mM), respectively. Given the low sensitivities in the higher concentration range, saturation for carbon sensors and locally modified platinum microneedle sensors starts at 10 mM and 5 mM lactate, respectively. Thus, both sensors allow sensitive measurements in the lower concentration range. Current densities at saturating lactate concentration are higher on freshly prepared carbon electrodes with 1.80 μA/mm 2 (10 mM) compared to platinum microneedle electrodes with 0.75 μA/mm 2 (10 mM) with full electrode modification. For platinum microneedle electrodes with optimized, dried local microneedle modification a current density of 0.95 μA/mm2 (5 mM) was measured. Detection of lactate in whole blood was demonstrated on carbon sensors, showing increasing currents after exercise, correlating with higher blood lactate levels, measured with a test strip reference system.
Third-generation biosensors use enzymes capable of direct electron transfer (DET) to the sensor surface. They are of interest for continuous glucose monitoring in blood or interstitial fluid, but they are rarely investigated. One reason is the hindered DET of the enzymes to the metallic electrodes. In this publication, a novel method for the immobilization of cellobiose dehydrogenase (CDH) DET enzymes employing conductive poly(3,4-ethylenedioxythiophene)-poly (styrene sulfonate) (PEDOT:PSS) inks and a protective polyethylene glycol dimethacrylate (PEG-DMA) hydrogel layer on gold electrodes is reported. This layer stack showed a glucose-specific current response for voltages between −0.2 and 0.4 V in physiological PBS buffer, and enabled interference-less sensing in a solution of acetaminophen, ascorbic acid, dopamine, and uric acid at 0 V. A Michaelis–Menten fit led to a maximum current density (Imax) of 257 ± 7.9 nA/mm2 and a Michaelis–Menten constant (Km) of 28.4 ± 2.2 mM, with a dynamic range of 0.1–20 mM glucose and a limit of detection of 0.1 mM. After 16 h of continuous measurement of 20 mM glucose, the signal decreased to 60% of its initial value. Storage stability was successfully verified until up to 10 days. In summary, this paper shows a simplified approach for the fabrication of third-generation biosensors using CDH-PEDOT:PSS and PEG-DMA hydrogel inks.
Hydrogels are of great importance for functionalizing sensors and microfluidics, and poly(ethylene glycol) dimethacrylate (PEG-DMA) is often used as a viscosifier for printable hydrogel precursor inks. In this study, 1–10 kDa PEG-DMA based hydrogels were characterized by gravimetric and electrochemical methods to investigate the diffusivity of small molecules and proteins. Swelling ratios (SRs) of 14.43–9.24, as well as mesh sizes ξ of 3.58–6.91 nm were calculated, and it was found that the SR correlates with the molar concentration of PEG-DMA in the ink (MCI) (SR = 0.1127 × MCI + 8.3256, R2 = 0.9692) and ξ correlates with the molecular weight (Mw) (ξ = 0.3382 × Mw + 3.638, R2 = 0.9451). To investigate the sensing properties, methylene blue (MB) and MB-conjugated proteins were measured on electrochemical sensors with and without hydrogel coating. It was found that on sensors with 10 kDa PEG-DMA hydrogel modification, the DPV peak currents were reduced to 92 % for MB, 73 % for MB-BSA, and 23 % for MB-IgG. To investigate the diffusion properties of MB(-conjugates) in hydrogels with 1–10 kDa PEG-DMA, diffusivity was calculated from the current equation. It was found that diffusivity increases with increasing ξ. Finally, the release of MB-BSA was detected after drying the MB-BSA-containing hydrogel, which is a promising result for the development of hydrogel-based reagent reservoirs for biosensing.