Rianne van Melzen

Ms. Rianne van Melzen


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RMRianne van Melzen
Rianne van Melzen
MHMarjolein Haveman
Marjolein Haveman
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
KAKai van Amsterdam
Kai van Amsterdam
MMMostafa El Moumni
Mostafa El Moumni
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
(1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.

27 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
RMRianne van Melzen
Rianne van Melzen
MHMarjolein Haveman
Marjolein Haveman
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
MSMichel MRF Struys
Michel MRF Struys
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.

3 June 2022 in Expert Review of Medical Devices
Verified
Journal Article
Open access
MHMarjolein Haveman
Marjolein Haveman
RMRianne van Melzen
Rianne van Melzen
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
HHHermie Hermens
Hermie Hermens
MTMonique Tabak
Monique Tabak
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
Telemonitoring during the perioperative trajectory may improve patient outcomes and self-management. The aim of this study is to assess the feasibility of and patient’s experiences with telemonitor...

3 December 2021 in Expert Review of Medical Devices
Verified
Journal Article
Open access
MHMarjolein Haveman
Marjolein Haveman
RMRianne van Melzen
Rianne van Melzen
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
MMMostafa El Moumni
Mostafa El Moumni
HHHermie Hermens
Hermie Hermens
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
Wearable sensors enable continuous vital sign monitoring, although information about their performance on nursing wards is scarce. Vital signs measured by telemonitoring and nurse measurements on a...

28 November 2022 in JMIR Perioperative Medicine
Verified
Journal Article
Open access
MHMarjolein Haveman
Marjolein Haveman
RMRianne van Melzen
Rianne van Melzen
MMMostafa El Moumni
Mostafa El Moumni
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
HHHermie Hermens
Hermie Hermens
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
Background: Preoperative telemonitoring of vital signs, physical activity, and well-being might be able to optimize prehabilitation of the patient’s physical and mental condition prior to surgery, support setting alarms during in-hospital monitoring, and allow personalization of the postoperative recovery process. Objective: The primary aim of this study was to evaluate when and how long patients awaiting major abdominal surgery should be monitored to get reliable preoperative individual baseline values of heart rate (HR), daily step count, and patient-reported outcome measures (PROMs). The secondary aim was to describe the perioperative course of these measurements at home. Methods: In this observational single-center cohort study, patients used a wearable sensor during waking hours and reported PROMs (pain, anxiety, fatigue, nausea) on a tablet twice a day. Intraclass correlation coefficients (ICCs) were used to evaluate the reliability of mean values on 2 specific preoperative days (the first day of telemonitoring and the day before hospital admission) and randomly selected preoperative periods compared to individual reference values. Mean values of HR, step count, and PROMs per day were visualized in a boxplot from 14 days before hospital admission until 30 days after surgery. Results: A total of 16 patients were included in the data analyses. The ICCs of mean values on the first day of telemonitoring were 0.91 for HR, 0.71 for steps, and at least 0.86 for PROMs. The day before hospital admission showed reliability coefficients of 0.76 for HR, 0.71 for steps, and 0.92-0.99 for PROMs. ICC values of randomly selected measurement periods increased over the continuous period of time from 0.68 to 0.99 for HR and daily step counts. A lower bound of the 95% CI of at least 0.75 was determined after 3 days of measurements. The ICCs of randomly selected PROM measurements were 0.89-0.94. Visualization of mean values per day mainly showed variable preoperative daily step counts (median 2409, IQR 1735-4661 steps/day) and lower postoperative daily step counts (median 884, IQR 474-1605 steps/day). In addition, pain was visually reduced until 30 days after surgery at home. Conclusions: In this prospective pilot study, for patients awaiting major abdominal surgery, baseline values for HR and daily step count could be measured reliably by a wearable sensor worn for at least 3 consecutive days and PROMs during any preoperative day. No clear conclusions were drawn from the description of the perioperative course by showing mean values of HR, daily step count, and PROM values over time in the home situation.