Kai van Amsterdam

Mr. Kai van Amsterdam

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RMRianne van Melzen
Rianne van Melzen
MHMarjolein Haveman
Marjolein Haveman
RSRichte C.L. Schuurmann
Richte C.L. Schuurmann
KAKai van Amsterdam
Kai van Amsterdam
MMMostafa El Moumni
Mostafa El Moumni
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
(1) Background: Wearable sensors support healthcare professionals in clinical decision-making by measuring vital parameters such as heart rate (HR), respiration rate (RR), and blood oxygenation saturation (SpO2). This study assessed the validity and reliability of two types of wearable sensors, based on electrocardiogram or photoplethysmography, compared with continuous monitoring of patients recovering from trauma surgery at the postanesthesia care unit. (2) Methods: In a prospective observational study, HR, RR, SpO2, and temperature of patients were simultaneously recorded with the VitalPatch and Radius PPG and compared with reference monitoring. Outcome measures were formulated as correlation coefficient for validity and mean difference with 95% limits of agreement for reliability for four random data pairs and 30-min pairs per vital sign per patient. (3) Results: Included were 60 patients. Correlation coefficients for VitalPatch were 0.57 to 0.85 for HR and 0.08 to 0.16 for RR, and for Radius PPG, correlation coefficients were 0.60 to 0.83 for HR, 0.20 to 0.12 for RR, and 0.57 to 0.61 for SpO2. Both sensors presented mean differences within the cutoff values of acceptable difference. (4) Conclusions: Moderate to strong correlations for HR and SpO2 were demonstrated. Although mean differences were within acceptable cutoff values for all vital signs, only limits of agreement for HR measured by electrocardiography were considered clinically acceptable.

19 December 2023 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Closed access
PDF file
RVRemco Vellinga
Remco Vellinga
MIMichele Introna
Michele Introna
KAKai van Amsterdam
Kai van Amsterdam
XZX. Y. Tommy Zhou
X. Y. Tommy Zhou
TSTom De Smet
Tom De Smet
JBJohannes P. van Den Berg
Johannes P. van Den Berg

5 February 2013 in British Journal of Anaesthesia
Verified
Journal Article
Open access
PDF file
KAKai van Amsterdam
Kai van Amsterdam
FCFokie Cnossen
Fokie Cnossen
ABA. Ballast
A. Ballast
MSM. M. R. F. Struys
M. M. R. F. Struys
Previous research using a metaphorical anaesthesia monitor, where dimensions of rectangles proportionally represent 30 patient variable values, showed improved performance in diagnosing adverse events compared with the standard monitor. Steady-state values were represented by a frame around each rectangle. We developed a similar metaphorical anaesthesia interface, but instead of presenting four relatively simple complications, we presented 10 complications of various levels of difficulty. Our simplified monitor presented variables that anaesthetists and trainees suggested as being essential for diagnosis. Thirty-two anaesthetists and anaesthesia trainees participated in the monitoring task. Three types of monitors were presented: standard monitor, metaphorical monitor, and metaphorical monitor with trend arrows emphasizing the direction of change. The subjects were presented with screenshots of the three monitor types displaying anaesthesia-related complications. They were asked to indicate treatment method and diagnosis for the displayed complication. No significant differences were found in time to diagnosis and accuracy between the metaphorical and standard monitor. There were also no differences between trend and no-trend monitors. Forty per cent of the complications were identified incorrectly. Visual metaphors on anaesthesia monitors do not improve anaesthetists' performance in the operating theatre. Since all complications in this study were identifiable based on monitor values alone, it seems feasible to develop a decision support system (DSS) based on these values. We suggest that a DSS could support the anaesthetist by calling attention to diagnoses that may not be considered.

20 July 2024 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
OMO. M. Marges
O. M. Marges
JNJ. P. Nieboer
J. P. Nieboer
IKI. N. de Keijzer
I. N. de Keijzer
RRR. Rettab
R. Rettab
KAKai van Amsterdam
Kai van Amsterdam
JBJ. P. van Den Berg
J. P. van Den Berg
Post-induction hypotension (MAP < 65 mmHg) occurs frequently and is usually caused by the cardiovascular adverse effects of the anaesthetic induction drugs used. We hypothesize that a clinically significant difference in the incidence and severity of hypotension will be found when different doses of propofol and remifentanil are used for induction of anaesthesia. Methods: This is a secondary analysis of a randomised controlled trial wherein four groups (A-D) of patients received one out of four different combinations of propofol and remifentanil, titrated to a predicted equipotency in probability of tolerance to laryngoscopy (PTOL) according to the Bouillon interaction model. In group A, a high dose of propofol and a low dose of remifentanil was administered, and across the groups this ratio was gradually changed until it was reversed in group D. Mean and systolic arterial blood pressure (MAP, SAP) were compared at four time points (Tbaseline, Tpost−bolus, T3min, Tnadir) within and between groups Heart rate, bispectral index (BIS) and the incidence of hypotension were compared. Results: Data from 76 patients was used. At Tpost−bolus a statistically significant lower MAP and SAP was found in group A versus D (p = 0.011 and p = 0.002). A significant higher heart rate was found at T3min and Tnadir between groups A and B when compared to groups C and D (p = < 0.001 and p = 0.002). A significant difference in BIS value was found over all groups at T3min and Tnadir (both p < 0.001). All other outcomes did not differ significantly between groups. Conclusion: Induction of anaesthesia with different predicted equipotent combinations of propofol and remifentanil did result in statistically different but clinically irrelevant differences in haemodynamic endpoints during induction of anaesthesia. Our study could not identify preferable drug combinations that decrease the risk for hypotension after induction, although they all yield a similar predicted PTOL.

3 September 2025 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
DMDario Massari
Dario Massari
MMMarco Modestini
Marco Modestini
CNCornelia K. Niezen
Cornelia K. Niezen
LYLu Yeh
Lu Yeh
AZAnna Carina Zoutman
Anna Carina Zoutman
JVJaap Jan Vos
Jaap Jan Vos
Purpose: Pediatric patients undergoing cardiac surgery are at risk of developing postoperative acute kidney injury (AKI). We hypothesized that a reduction in intraoperative renal (SrO 2 ) or cerebral (ScO 2 ) tissue oxygen saturation is associated with postoperative AKI. Methods: We conducted a prospective observational study including fifty pediatric patients with non-cyanotic heart disease undergoing elective surgical repair with cardiopulmonary bypass. Intraoperative SrO 2 and ScO 2 were monitored using near-infrared spectroscopy (O3 ® Regional Oximetry). Relative decreases of 10% and 20% from baseline SrO 2 and ScO 2 were analysed, calculating the total time below the threshold, area under the threshold, and time-weighted average. The primary outcome was the association between intraoperative SrO 2 and ScO 2 decreases, and the occurrence of postoperative AKI defined with the ‘Kidney Disease: Improving Global Outcomes’ criteria. Secondary outcomes included the association between other known or potential risk factors for AKI and postoperative AKI. Results: The incidence of postoperative AKI was 18.4%. There was no association between the duration and extent of intraoperative reductions of SrO 2 and ScO 2 below 10% and 20% from baseline, and postoperative AKI (e.g., area under the threshold for ScO 2 decreases below 10%: 36.8 [11.8 to 419.9] % min in patients with AKI vs. 9.6 [0.6 to 92.8] % min in patients without AKI, P = 0.117). Preoperative serum creatinine, body mass index, intraoperative hypotension, and blood lactate were associated with postoperative AKI. Conclusion: A decrease in intraoperative renal or cerebral tissue oxygen saturation was not associated with postoperative AKI in pediatric patients undergoing surgery for non-cyanotic congenital heart disease.

11 September 2026 in BJA Open
Verified
Journal Article
Open access
CBClemens R.M. Barends
Clemens R.M. Barends
KAKai van Amsterdam
Kai van Amsterdam
DEDouglas J. Eleveld
Douglas J. Eleveld
JVJaap Jan Vos
Jaap Jan Vos
AAAnthony R. Absalom
Anthony R. Absalom