Rajarajan Ramalingame

Mr. Rajarajan Ramalingame


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Olfa KanounOlfa Kanoun
Olfa Kanoun
Ayda BouhamedAyda Bouhamed
Ayda Bouhamed
RRRajarajan Ramalingame
Rajarajan Ramalingame
JBJosé Roberto Bautista-Quijano
José Roberto Bautista-Quijano
DRDHIVAKAR RAJENDRAN
DHIVAKAR RAJENDRAN
AAAmmar Al-Hamry
Ammar Al-Hamry
In the last decade, significant developments of flexible and stretchable force sensors have been witnessed in order to satisfy the demand of several applications in robotic, prosthetics, wearables and structural health monitoring bringing decisive advantages due to their manifold customizability, easy integration and outstanding performance in terms of sensor properties and low-cost realization. In this paper, we review current advances in this field with a special focus on polymer/carbon nanotubes (CNTs) based sensors. Based on the electrical properties of polymer/CNTs nanocomposite, we explain underlying principles for pressure and strain sensors. We highlight the influence of the manufacturing processes on the achieved sensing properties and the manifold possibilities to realize sensors using different shapes, dimensions and measurement procedures. After an intensive review of the realized sensor performances in terms of sensitivity, stretchability, stability and durability, we describe perspectives and provide novel trends for future developments in this intriguing field.

8 February 2019 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
RRRajarajan Ramalingame
Rajarajan Ramalingame
ALAmoog Lakshmanan
Amoog Lakshmanan
FMFlorian Müller
Florian Müller
UTUlrike Thomas
Ulrike Thomas
OKOlfa Kanoun
Olfa Kanoun
Flexible tactile pressure sensor arrays based on multiwalled carbon nanotubes (MWCNT) and polydimethylsiloxane (PDMS) are gaining importance, especially in the field of robotics because of the high demand for stable, flexible and sensitive sensors. Some existing concepts of pressure sensors based on nanocomposites exhibit complicated fabrication techniques and better sensitivity than the conventional pressure sensors. In this article, we propose a nanocomposite-based pressure sensor that exhibits a high sensitivity of 25 % N−1, starting with a minimum load range of 0–0.01 N and 46.8 % N−1 in the range of 0–1 N. The maximum pressure sensing range of the sensor is approximately 570 kPa. A concept of a 4×3 tactile sensor array, which could be integrated to robot fingers, is demonstrated. The high sensitivity of the pressure sensor enables precision grasping, with the ability to sense small objects with a size of 5 mm and a weight of 1 g. Another application of the pressure sensor is demonstrated as a gait analysis for humanoid robots. The pressure sensor is integrated under the foot of a humanoid robot to monitor and evaluate the gait of the robot, which provides insights for optimizing the robot's self-balancing algorithm in order to maintain the posture while walking.

8 January 2019 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
RRRajarajan Ramalingame
Rajarajan Ramalingame
ZHZheng Hu
Zheng Hu
CGCarina Gerlach
Carina Gerlach
DRDhivakar Rajendran
Dhivakar Rajendran
TZTatiana Zubkova
Tatiana Zubkova
OKOlfa Kanoun
Olfa Kanoun
A highly flexible, piezoresistive sensor matrix based on a carbon nanotube (CNT) polymer composite is developed for pressure distribution measurement applications. With an overall height of about 400 µm, the sensors can measure pressure directly, without any deformation elements, such as a cantilever or a deformation membrane. The measurement range is from 2.5 to 640 kPa. Both the position and the pressure of the applied load can be measured and visualized as a resistance change. The relative resistance measurement deviation of the data acquisition system is lower than 3 % for the resistance range of 610Ω to 380 kΩ. This corresponds to a systematic deviation of pressure measurement of less than 3 % in the measurement range. Besides the measurement of pressure, different sizes of loads can be detected as well. The developed fast and compact measurement system allows dynamic pressure measurement, such as gait analysis when used in an insole application.

10 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DRDHIVAKAR RAJENDRAN
DHIVAKAR RAJENDRAN
RRRajarajan Ramalingame
Rajarajan Ramalingame
SPSaravanan Palaniyappan
Saravanan Palaniyappan
GWGuntram Wagner
Guntram Wagner
Olfa KanounOlfa Kanoun
Olfa Kanoun
Foot pressure measurement plays an essential role in healthcare applications, clinical rehabilitation, sports training and pedestrian navigation. Among various foot pressure measurement techniques, in-shoe sensors are flexible and can measure the pressure distribution accurately. In this paper, we describe the design and characterization of flexible and low-cost multi-walled carbon nanotubes (MWCNT)/Polydimethylsiloxane (PDMS) based pressure sensors for foot pressure monitoring. The sensors have excellent electrical and mechanical properties an show a stable response at constant pressure loadings for over 5000 cycles. They have a high sensitivity of 4.4 kΩ/kPa and the hysteresis effect corresponds to an energy loss of less than 1.7%. The measurement deviation is of maximally 0.13% relative to the maximal relative resistance. The sensors have a measurement range of up to 330 kPa. The experimental investigations show that the sensors have repeatable responses at different pressure loading rates (5 N/s to 50 N/s). In this paper, we focus on the demonstration of the functionality of an in-sole based on MWCNT/PDMS nanocomposite pressure sensors, weighing approx. 9.46 g, by investigating the foot pressure distribution while walking and standing. The foot pressure distribution was investigated by measuring the resistance changes of the pressure sensors for a person while walking and standing. The results show that pressure distribution is higher in the forefoot and the heel while standing in a normal position. The foot pressure distribution is transferred from the heel to the entire foot and further transferred to the forefoot during the first instance of the gait cycle.

18 May 2021 in IEEE Sensors Letters
Verified
Journal Article
Closed access
RRRajarajan Ramalingame
Rajarajan Ramalingame
RBRim Barioul
Rim Barioul
XLXupeng Li
Xupeng Li
GSGiuseppe Sanseverino
Giuseppe Sanseverino
DKDominik Krumm
Dominik Krumm
Olfa KanounOlfa Kanoun
Olfa Kanoun
The conventional camera-based systems and electronic gloves for gesture recognition are limited by the influence of lighting conditions, occlusions, and movement restrictions. A wearable smart band with integrated nanocomposite pressure sensors has been developed to overcome these shortcomings. The sensors consist of homogeneously dispersed carbon nanotubes in a polydimethylsiloxane polymer matrix prepared by an optimized synthesis process. The sensor band can actively monitor contractions/relaxations of muscles in the arm due to the sensor's high sensitivity in the low forces and stability. The band has eight sensors placed on a stretchable adhesive textile material and connected to a data logger with a multiplexed sensor interface and wireless communication capabilities. The novel smart band was validated by measurements on ten subjects to perform numerical gestures in American sign language from 0 to 9 with ten trials each. The data were recorded at 100 Hz, and a total of 100 datasets were generated for each subject. By feeding the datasets to an extreme machine learning algorithm that selects features, weights, and biases to classify the gestures, an overall gesture recognition accuracy of 93% could be achieved.

7 November 2019 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
RRRajarajan Ramalingame
Rajarajan Ramalingame
JBJosé Roberto Bautista-Quijano
José Roberto Bautista-Quijano
DADanrlei Alves
Danrlei Alves
Olfa KanounOlfa Kanoun
Olfa Kanoun
Sensors based on carbon nanomaterials are gaining importance due to their tunable properties and their potentially outstanding sensing performance. Despite their advantages, carbon-based nanomaterial sensors are prone to cross-sensitivities with environmental factors like temperature. Thus, to reduce the temperature influence on the sensing material, compensation and correction procedures are usually considered. These methods may require the use of additional sensors which can themselves be subject to residual errors. Hence, a more promising approach consists of synthesizing a material that is capable of self-compensating for the influence of temperature. In this study, a hybrid nanocomposite based on multi-walled carbon nanotubes (MWCNT) and graphene is proposed, which can compensate, by itself, for the influence of temperature on the material conductivity. The hybrid nanocomposite material uses the different temperature behavior of MWCNTs, which have a negative temperature coefficient, and graphene, which has a positive temperature coefficient. The influence of the material ratio and dispersion quality are investigated in this work. Material composition and dispersion quality are analyzed using Raman spectroscopy and scanning electron microscopy (SEM). A composition of 70% graphene and 30% MWCNT exhibits a nearly temperature-independent hybrid nanocomposite with a sensitivity of 0.022 Ω/°C, corresponding to a resistance change of ~1.2 Ω for a temperature range of 25 to 80 °C. Additionally, a simple investigation of the strain sensing behavior of the hybrid material is also presented. The hybrid nanocomposite-based, thin-film strain sensor exhibits good stability over 100 cycles and a significantly high gauge factor, i.e., 16.21.