Ahmed Shehata

Dr. Ahmed Shehata

University of Alberta
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2021 in Science Robotics
Verified
Journal Article
Closed access
PMPaul D. Marasco
Paul D. Marasco
JHJacqueline Hebert
Jacqueline Hebert
JSJonathon W. Sensinger
Jonathon W. Sensinger
DBDylan T. Beckler
Dylan T. Beckler
ZTZachary C. Thumser
Zachary C. Thumser
KWKathleen R. Wilson
Kathleen R. Wilson
Multiperspective analysis reveals neurorobotic sensory and motor fusion in a bionic system promotes intrinsic neural behaviors.

14 April 2008 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmed ShehataAhmed Shehata
Ahmed Shehata
WMWalied Moussa
Walied Moussa
ELEdmond Lou
Edmond Lou
In this article, we report on the new design of a miniaturized strain microsensor. The proposed sensor utilizes the piezoresistive properties of doped single crystal silicon. Employing the Micro Electro Mechanical Systems (MEMS) technology, high sensor sensitivities and resolutions have been achieved. The current sensor design employs different levels of signal amplifications. These amplifications include geometric, material and electronic levels. The sensor and the electronic circuits can be integrated on a single chip, and packaged as a small functional unit. The sensor converts input strain to resistance change, which can be transformed to bridge imbalance voltage. An analog output that demonstrates high sensitivity (0.03mV/me), high absolute resolution (1μe) and low power consumption (100μA) with a maximum range of ±4000μe has been reported. These performance characteristics have been achieved with high signal stability over a wide temperature range (±50oC), which introduces the proposed MEMS strain sensor as a strong candidate for wireless strain sensing applications under harsh environmental conditions. Moreover, this sensor has been designed, verified and can be easily modified to measure other values such as force, torque…etc. In this work, the sensor design is achieved using Finite Element Method (FEM) with the application of the piezoresistivity theory. This design process and the microfabrication process flow to prototype the design have been presented.

5 January 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
HWHeather E. Williams
Heather E. Williams
Ahmed ShehataAhmed Shehata
Ahmed Shehata
MDMichael R. Dawson
Michael R. Dawson
ESErik Scheme
Erik Scheme
JHJacqueline Hebert
Jacqueline Hebert
PPPatrick Pilarski
Patrick Pilarski
Objective: Persons with normal arm function can perform complex wrist and hand movements over a wide range of limb positions. However, for those with transradial amputation who use myoelectric prostheses, control across multiple limb positions can be challenging, frustrating, and can increase the likelihood of device abandonment. In response, the goal of this research was to investigate convolutional neural network (RCNN)-based position-aware myoelectric prosthesis control strategies. Methods: Surface electromyographic (EMG) and inertial measurement unit (IMU) signals, obtained from 16 non-disabled participants wearing two Myo armbands, served as inputs to RCNN classification and regression models. Such models predicted movements (wrist flexion/extension and forearm pronation/supination), based on a multi-limb-position training routine. RCNN classifiers and RCNN regressors were compared to linear discriminant analysis (LDA) classifiers and support vector regression (SVR) regressors, respectively. Outcomes were examined to determine whether RCNN-based control strategies could yield accurate movement predictions, while using the fewest number of available Myo armband data streams. Results: An RCNN classifier (trained with forearm EMG data, and forearm and upper arm IMU data) predicted movements with 99.00% accuracy (versus the LDA's 97.67%). An RCNN regressor (trained with forearm EMG and IMU data) predicted movements with R 2 values of 84.93% for wrist flexion/extension and 84.97% for forearm pronation/supination (versus the SVR's 77.26% and 60.73%, respectively). The control strategies that employed these models required fewer than all available data streams. Conclusion: RCNN-based control strategies offer novel means of mitigating limb position challenges. Significance: This research furthers the development of improved position-aware myoelectric prosthesis control.

18 April 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
Ahmed ShehataAhmed Shehata
Ahmed Shehata
ESErik Scheme
Erik Scheme
JSJonathon W. Sensinger
Jonathon W. Sensinger
Ongoing developments in myoelectric prosthesis control have provided prosthesis users with an assortment of control strategies that vary in reliability and performance. Many studies have focused on improving performance by providing feedback to the user, but have overlooked the effect of this feedback on internal model development, which is key to improving long-term performance. In this work, the strength of internal models developed for two commonly used myoelectric control strategies: raw control with raw feedback (using a regression-based approach), and filtered control with filtered feedback (using a classifier-based approach), were evaluated using two psychometric measures: trial-by-trial adaptation and just-noticeable-difference. The performance of both strategies was also evaluated using a Schmidt’s style target acquisition task. Results obtained from 24 able-bodied subjects showed that although filtered control with filtered feedback had better short-term performance in path efficiency (p < 0.05), raw control with raw feedback resulted in stronger internal model development (p < 0.05), which may lead to better long-term performance. Despite inherent noise in the control signals of the regression controller, these findings suggest that rich feedback associated with regression control may be used to improve human understanding of the myoelectric control system.

31 July 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
Ahmed ShehataAhmed Shehata
Ahmed Shehata
LELeonard F. Engels
Leonard F. Engels
Marco ControzziMarco Controzzi
Marco Controzzi
CCChristian Cipriani
Christian Cipriani
ESErik Scheme
Erik Scheme
JSJonathon W. Sensinger
Jonathon W. Sensinger
The loss of an arm presents a substantial challenge for upper limb amputees when performing activities of daily living. Myoelectric prosthetic devices partially replace lost hand functions; however, lack of sensory feedback and strong understanding of the myoelectric control system prevent prosthesis users from interacting with their environment effectively. Although most research in augmented sensory feedback has focused on real-time regulation, sensory feedback is also essential for enabling the development and correction of internal models, which in turn are used for planning movements and reacting to control variability faster than otherwise possible in the presence of sensory delays. Our recent work has demonstrated that audio-augmented feedback can improve both performance and internal model strength for an abstract target acquisition task. Here we use this concept in controlling a robotic hand, which has inherent dynamics and variability, and apply it to a more functional grasp-and-lift task. We assessed internal model strength using psychophysical tests and used an instrumented Virtual Egg to assess performance. Results obtained from 14 able-bodied subjects show that a classifier-based controller augmented with audio feedback enabled stronger internal model (p = 0.018) and better performance (p = 0.028) than a controller without this feedback. We extended our previous work and accomplished the first steps on a path towards bridging the gap between research and clinical usability of a hand prosthesis. The main goal was to assess whether the ability to decouple internal model strength and motion variability using the continuous audio-augmented feedback extended to real-world use, where the inherent mechanical variability and dynamics in the mechanisms may contribute to a more complicated interplay between internal model formation and motion variability. We concluded that benefits of using audio-augmented feedback for improving internal model strength of myoelectric controllers extend beyond a virtual target acquisition task to include control of a prosthetic hand.

4 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Ahmed ShehataAhmed Shehata
Ahmed Shehata
ESErik Scheme
Erik Scheme
JSJonathon W. Sensinger
Jonathon W. Sensinger
Myoelectric prosthetic devices are commonly used to help upper limb amputees perform activities of daily living, however amputees still lack the sensory feedback required to facilitate reliable and precise control. Augmented feedback may play an important role in affecting both short-term performance, through real-time regulation, and long-term performance, through the development of stronger internal models. In this work, we investigate the potential tradeoff between controllers that enable better short-term performance and those that provide sufficient feedback to develop a strong internal model. We hypothesize that augmented feedback may be used to mitigate this tradeoff, ultimately improving both short and long-term control. We used psychometric measures to assess the internal model developed while using a filtered myoelectric controller with augmented audio feedback, imitating classification-based control but with augmented regression-based feedback. In addition, we evaluated the short-term performance using a multi degree-of-freedom constrained-time target acquisition task. Results obtained from 24 able-bodied subjects show that an augmented feedback control strategy using audio cues enables the development of a stronger internal model than the filtered control with filtered feedback, and significantly better path efficiency than both raw and filtered control strategies. These results suggest that the use of augmented feedback control strategies may improve both short-term and long-term performance.