Myeongsoo Kim

Prof. Myeongsoo Kim

Radiation Oncology, Keimyung University Dongsan Hospital, Daegu, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2021 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
SASang Hee Ahn
Sang Hee Ahn
EKEunSook Kim
EunSook Kim
CKChankyu Kim
Chankyu Kim
WCWonjoong Cheon
Wonjoong Cheon
MKMyeongsoo Kim
Myeongsoo Kim
JJJong Hwi Jeong
Jong Hwi Jeong
Background: Patient-specific dose prediction improves the efficiency and quality of radiation treatment planning and reduces the time required to find the optimal plan. In this study, a patient-specific dose prediction model was developed for a left-sided breast clinical case using deep learning, and its performance was compared with that of conventional knowledge-based planning using RapidPlan™. Methods: Patient-specific dose prediction was performed using a contour image of the planning target volume (PTV) and organs at risk (OARs) with a U-net-based modified dose prediction neural network. A database of 50 volumetric modulated arc therapy (VMAT) plans for left-sided breast cancer patients was utilized to produce training and validation datasets. The dose prediction deep neural network (DpNet) feature weights of the previously learned convolution layers were applied to the test on a cohort of 10 test sets. With the same patient data set, dose prediction was performed for the 10 test sets after training in RapidPlan. The 3D dose distribution, absolute dose difference error, dose-volume histogram, 2D gamma index, and iso-dose dice similarity coefficient were used for quantitative evaluation of the dose prediction. Results: The mean absolute error (MAE) and one standard deviation (SD) between the clinical and deep learning dose prediction models were 0.02 ± 0.04%, 0.01 ± 0.83%, 0.16 ± 0.82%, 0.52 ± 0.97, − 0.88 ± 1.83%, − 1.16 ± 2.58%, and − 0.97 ± 1.73% for D95%, Dmean in the PTV, and the OARs of the body, left breast, heart, left lung, and right lung, respectively, and those measured between the clinical and RapidPlan dose prediction models were 0.02 ± 0.14%, 0.87 ± 0.63%, − 0.29 ± 0.98%, 1.30 ± 0.86%, − 0.32 ± 1.10%, 0.12 ± 2.13%, and − 1.74 ± 1.79, respectively. Conclusions: In this study, a deep learning method for dose prediction was developed and was demonstrated to accurately predict patient-specific doses for left-sided breast cancer. Using the deep learning framework, the efficiency and accuracy of the dose prediction were compared to those of RapidPlan. The doses predicted by deep learning were superior to the results of the RapidPlan-generated VMAT plan.

5 February 2025 in ACS Nano
Verified
Journal Article
Open access
KKKelsey P. Kubelick
Kelsey P. Kubelick
JKJinhwan Kim
Jinhwan Kim
MKMyeongsoo Kim
Myeongsoo Kim
XHXinyue Huang
Xinyue Huang
CWChenxiao Wang
Chenxiao Wang
SEStanislav Emelianov
Stanislav Emelianov
Despite great promise, adoptive cell therapy (ACT) continues to fail at treating a majority of cancers, especially solid tumors. To inform development and expedite the translation of more potent cellular immunotherapies, advanced immunoimaging tools are needed to better understand the in vivo requirements for generating a robust immune response. Even methods to evaluate the delivery, location, and status of transferred T cells at the tumor target are lacking. Therefore, a real-time, safe, noninvasive, longitudinal imaging method is critically needed to 1) monitor adoptive T cell location and status and 2) assess treatment progression and response through imaging biomarkers. Here, we developed a combined ultrasound (US) and photoacoustic (PA) imaging approach to enable T cell tracking following adoptive transfer for cancer immunotherapy. Our approach leverages highly photostable gold nanorods and cell surface engineering to tag the T cells without impacting effector functions, as well as generate PA contrast for imaging post-transfer. Our in vivo US/PA imaging approach detected nanoparticle-labeled T cell accumulation at the tumor, visualized changes in tumor volume, and conveyed accompanying changes in blood biomarkers. US/PA data also showed different trends according to a positive or negative antitumor response to T cell therapy over 7 days. Results highlight the potential of the approach and motivate future development to expand the platform for advanced, theranostic immunoimaging.


9 June 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KKKwang Hyeon Kim
Kwang Hyeon Kim
KPKyeongyun Park
Kyeongyun Park
HKHaksoo Kim
Haksoo Kim
BJByungdu Jo
Byungdu Jo
SASang Hee Ahn
Sang Hee Ahn
JJJong Hwi Jeong
Jong Hwi Jeong
Purpose: Imaging, breath‐holding/gating, and fixation devices have been developed to minimize setup errors so that the prescribed dose can be exactly delivered to the target volume in radiotherapy. Despite these efforts, additional patient monitoring devices have been installed in the treatment room to view patients’ whole‐body movement. We developed a facial expression recognition system using deep learning with a convolutional neural network (CNN) to predict patients’ advanced movement, enhancing the stability of the radiation treatment by giving warning signs to radiation therapists.Materials and methods: Convolutional neural network model and extended Cohn‐Kanade datasets with 447 facial expressions of source images for training were used. Additionally, a user interface that can be used in the treatment control room was developed to monitor real‐time patient's facial expression in the treatment room, and the entire system was constructed by installing a camera in the treatment room. To predict the possibility of patients' sudden movement, we categorized facial expressions into two groups: (a) uncomfortable expressions and (b) comfortable expressions. We assumed that the warning sign about the sudden movement was given when the uncomfortable expression was recognized.Results: We have constructed the facial expression monitoring system, and the training and test accuracy were 100% and 85.6%, respectively. In 10 patients, their emotions were recognized based on their comfortable and uncomfortable expressions with 100% detection rate. The detected various emotions were represented by a heatmap and motion prediction accuracy was analyzed for each patient.Conclusion: We developed a system that monitors the patient's facial expressions and predicts patient's advanced movement during the treatment. It was confirmed that our patient monitoring system can be complementarily used with the existing monitoring system. This system will help in maintaining the initial setup and improving the accuracy of radiotherapy for the patients using deep learning in radiotherapy.

22 August 2023 in Advanced Functional Materials
Verified
Journal Article
Closed access
MKMyeongsoo Kim
Myeongsoo Kim
JKJinhwan Kim
Jinhwan Kim
DVDon VanderLaan
Don VanderLaan
KKKelsey P. Kubelick
Kelsey P. Kubelick
AJAnamik Jhunjhunwala
Anamik Jhunjhunwala
SEStanislav Emelianov
Stanislav Emelianov

11 June 2022 in Cancers
Verified
Journal Article
Open access
PDF file
MKMyeongsoo Kim
Myeongsoo Kim
UHUi-Jung Hwang
Ui-Jung Hwang
KPKyeongyun Park
Kyeongyun Park
DKDohyeon Kim
Dohyeon Kim
HKHaksoo Kim
Haksoo Kim
임L임영경 Young Kyung Lim
임영경 Young Kyung Lim
The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.