Myeongsoo Kim

Myeongsoo Kim

Auto-generated profile, based on publicly available information

Myeongsoo Kim

Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2025 in ACS Nano
Verified
Journal Article
Open access
KKKelsey Kubelick
Kelsey Kubelick
JKJinhwan Kim
Jinhwan Kim
MKMyeongsoo Kim
Myeongsoo Kim
XHXinyue Huang
Xinyue Huang
CWChenxiao Wang
Chenxiao Wang
SEStanislav Emelianov
Stanislav Emelianov
Despite great promise, adoptive cell therapy (ACT) continues to fail at treating a majority of cancers, especially solid tumors. To inform development and expedite the translation of more potent cellular immunotherapies, advanced immunoimaging tools are needed to better understand the in vivo requirements for generating a robust immune response. Even methods to evaluate the delivery, location, and status of transferred T cells at the tumor target are lacking. Therefore, a real-time, safe, noninvasive, longitudinal imaging method is critically needed to 1) monitor adoptive T cell location and status and 2) assess treatment progression and response through imaging biomarkers. Here, we developed a combined ultrasound (US) and photoacoustic (PA) imaging approach to enable T cell tracking following adoptive transfer for cancer immunotherapy. Our approach leverages highly photostable gold nanorods and cell surface engineering to tag the T cells without impacting effector functions, as well as generate PA contrast for imaging post-transfer. Our in vivo US/PA imaging approach detected nanoparticle-labeled T cell accumulation at the tumor, visualized changes in tumor volume, and conveyed accompanying changes in blood biomarkers. US/PA data also showed different trends according to a positive or negative antitumor response to T cell therapy over 7 days. Results highlight the potential of the approach and motivate future development to expand the platform for advanced, theranostic immunoimaging.


9 June 2020 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KKKwang Hyeon Kim
Kwang Hyeon Kim
KPKyeongyun Park
Kyeongyun Park
HKHaksoo Kim
Haksoo Kim
BJByungdu Jo
Byungdu Jo
SASang Hee Ahn
Sang Hee Ahn
JJJong Hwi Jeong
Jong Hwi Jeong
Purpose: Imaging, breath‐holding/gating, and fixation devices have been developed to minimize setup errors so that the prescribed dose can be exactly delivered to the target volume in radiotherapy. Despite these efforts, additional patient monitoring devices have been installed in the treatment room to view patients’ whole‐body movement. We developed a facial expression recognition system using deep learning with a convolutional neural network (CNN) to predict patients’ advanced movement, enhancing the stability of the radiation treatment by giving warning signs to radiation therapists.Materials and methods: Convolutional neural network model and extended Cohn‐Kanade datasets with 447 facial expressions of source images for training were used. Additionally, a user interface that can be used in the treatment control room was developed to monitor real‐time patient's facial expression in the treatment room, and the entire system was constructed by installing a camera in the treatment room. To predict the possibility of patients' sudden movement, we categorized facial expressions into two groups: (a) uncomfortable expressions and (b) comfortable expressions. We assumed that the warning sign about the sudden movement was given when the uncomfortable expression was recognized.Results: We have constructed the facial expression monitoring system, and the training and test accuracy were 100% and 85.6%, respectively. In 10 patients, their emotions were recognized based on their comfortable and uncomfortable expressions with 100% detection rate. The detected various emotions were represented by a heatmap and motion prediction accuracy was analyzed for each patient.Conclusion: We developed a system that monitors the patient's facial expressions and predicts patient's advanced movement during the treatment. It was confirmed that our patient monitoring system can be complementarily used with the existing monitoring system. This system will help in maintaining the initial setup and improving the accuracy of radiotherapy for the patients using deep learning in radiotherapy.

22 August 2023 in Advanced Functional Materials
Verified
Journal Article
Closed access
MKMyeongsoo Kim
Myeongsoo Kim
JKJinhwan Kim
Jinhwan Kim
DVDon VanderLaan
Don VanderLaan
KKKelsey P. Kubelick
Kelsey P. Kubelick
AJAnamik Jhunjhunwala
Anamik Jhunjhunwala
SEStanislav Emelianov
Stanislav Emelianov

20 November 2020 in Small
Verified
Journal Article
Closed access
PDF file
MKMin Jun Ko
Min Jun Ko
BPBum Chul Park
Bum Chul Park
TKThomas Myeongseok Koo
Thomas Myeongseok Koo
YJYoo Sang Jeon
Yoo Sang Jeon
MKMyeongsoo Kim
Myeongsoo Kim
YKYoung Keun Kim
Young Keun Kim

3 December 2020 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
YKYu Jin Kim
Yu Jin Kim
MKMin Jun Ko
Min Jun Ko
BPBum Chul Park
Bum Chul Park
JMJun Hwan Moon
Jun Hwan Moon
YJYoo Sang Jeon
Yoo Sang Jeon
YKYoung Keun Kim
Young Keun Kim