Pressure mapping systems have been traditionally used to assess load distributions in individuals at risk of pressure ulcers. Recently, the technology has been adapted to monitor pressures over prolonged periods. The present study aims to investigate the predictive ability of selected biomechanical parameters estimated from pressure distributions for detecting postural changes in lying. Healthy participants (n = 11) were recruited and positioned in different lying postures, by utilizing the head of bed (HOB) angle and an automated tilting system to achieve evoked movements in the sagittal and transverse planes, respectively. Measurements included continuous monitoring of interface pressures and accelerations from the trunk and waist. Selected interface pressure parameters included; centre of pressure, contact area and pressure gradient. A threshold range for all parameters was established and Receiver Operating Characteristic (ROC) curves presented to determine the sensitivity and specificity for detecting postural changes. Temporal trends in the data revealed significant variance in the signal perturbations during each evoked postural change. Indeed, sensitivity and specificity were influenced by the specific threshold values and the relative position of the individual. As an example, sensitivity of some parameters exhibited a compromised trend at higher HOB angles, with low corresponding area under the ROC curve. By contrast, contact area provided the highest values, with 7/12 signals achieve AUC >0.5. This corresponded with actimetry signals, which provided high discrimination between postures. Parameters estimated from a commercial pressure monitoring can have the potential to detect postural changes. Further research is required to convert the data into meaningful clinical information, to inform patient repositioning strategies.
Aim: Individuals in the community with reduced mobility are at risk of exposure to prolonged lying and sitting postures, which may cause pressure ulcers. The present study combines continuous pressure monitoring technology and intelligent algorithms to evaluate posture, mobility, and pressure profiles in a cohort of community dwelling patients, who had acquired pressure ulcers. Materials and methods This study represents a secondary analysis of the data from the Quality Improvement project ‘Pressure Reduction through COntinuous Monitoring In the community SEtting (PROMISE)’. 22 patients with pressure ulcers were purposely selected from 105 recruited community residents. Data were collected using a commercial continuous pressure monitoring system over a period of 1 to 4 days, and analyzed with an intelligent algorithm using machine learning to determine posture and mobility events. Duration and magnitude of pressure signatures of each static posture and exposure thresholds were identified based on a sigmoid relationship between pressure and time. Results: Patients revealed a wide range of ages (30-95 years), BMI (17.5-47 kg/m2) and a series of co-morbidities, which may have influenced the susceptibility to skin damage. Posture, mobility, and pressure data revealed a high degree of inter-subject variability. Largest duration of static postures ranged between 1.7 to 19.8 hours, with 17/22 patients spending at least 60% of their monitoring period in static postures which lasted >2 hours. Data revealed that many patients spent prolonged periods with potentially harmful interface pressure conditions, including pressure gradients >60mmHg/cm. Conclusion: This study combined posture, mobility, and pressure data from a commercial pressure monitoring technology through an intelligent algorithm. The community residents who had acquired a pressure ulcer at the time of monitoring exhibited trends which exposed their skin and subdermal tissues to prolonged high pressures during static postures. These indicators need further validation through prospective clinical trials.
Measuring interface pressure is currently used in a variety of settings, e.g., automotive or clinical, to evaluate pressure distribution at support surface interfaces. Commercial pressure sensing arrays are employed to monitor and visualise these pressure distributions to aid mattress or cushion selection by assessing their ability to redistribute the pressure magnitudes over vulnerable areas, e.g., the buttock. These technologies vary in configurations and measurement principles, with manufacturers supplying calibration and specifications. This study evaluated the performance of six commercial pressure sensing arrays, which differed in sensor type, configuration, and spatial resolution. Each system was subjected to mechanical compression loading on a standard cushion using a dual hemispherical ‘buttock shaped’ standard indenter. Pressure parameters were estimated, e.g., contact area, peak pressure index, from the sensing arrays and a comparison between measured and predicted pressure values was performed. The results showed that both contact area and pressures are influenced by the spatial resolution, with higher values associated with systems with the highest resolution. A high variability between systems was observed in the measured pressure, with sensor type driving difference between the observed and the predicted pressures. Further research is needed to establish standards and performance analysis of these technologies.
When sitting, buttocks and thighs are subjected to higher pressures, which if sustained can be a risk factor in pressure ulcer development. This study aimed at evaluating the biomechanical and physiological performance of a dynamic sitting system incorporating pressure sensitive air cells technology to provide pressure relief and maintaining skin health. Thirteen participants were recruited and asked to adopt five static postures in a random order, each held for 10 min. Measurements at the chair-participant interface included interface pressure, internal pressure of the chair air cells, transcutaneous tissue gas tensions at the ischial tuberosities, and accelerometer data collected from the sternum. Area under the Receiver Operating Characteristic curve was used to evaluate sensitivity and specificity of all parameters in detecting postural change events, examining the 1st spatial derivative. Data revealed a high inter-subject variability, with interface pressure e.g. peak pressure gradient and contact area data showing statistically significant difference between postures. This was reflected in the physiological response with some individuals exhibiting low O2 levels and associated high CO2 (>25 % from baseline). Area under the curve values revealed interface pressure parameters and actimetry data accurate in detecting postural changes events (≥0.6). The dynamic seating support depended on posture, although there remained some significant differences in interface pressure values and local tissue physiology. Further research is required to assess the impact of these sitting conditions in vulnerable individuals.
12 August 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Preliminary human studies show that reduced skin temperature minimises the risk of mechanically induced skin damage. However, the mechanisms by which cooling enhances skin tolerance to pressure and shear remain poorly understood. We hypothesized that skin cooling below thermo-neutral conditions will decrease kinetic friction at the skin-material interface. To test our hypothesis, we measured the friction coefficient of a thermally pre-conditioned index finger pad sliding at a normal load (5N) across a plate maintained at three different temperatures (38, 24, and 16 °C) in 8 healthy young adults (29±5y). To quantify the temperature distribution of the skin tissue, we used 3D surface scanning and Optical Coherence Tomography to develop an anatomically representative thermal model of the finger. Our group-level data indicated that the sliding finger with thermally affected tissues (up to 8 mm depth) experienced significantly lower frictional forces (p<0.01) at plate temperatures of 16 °C (i.e. 32% decrease) and 24 °C (i.e. 13% decrease) than at 38 °C, respectively. This phenomenon occurred consistently across participants (i.e. N = 6/8, 75%) and without large changes in skin hydration during sliding. Our complementary experimental and theoretical results provide new insights into thermal modulation of skin friction that can be employed for developing thermal technologies to maintain skin integrity under mechanical loading and shearing.
Commercial pressure monitoring systems have been developed to assess conditions at the interface between mattress/cushions of individuals at risk of developing pressure ulcers. Recently, they have been used as a surrogate for prolonged posture and mobility monitoring. However, these systems typically consist of high-resolution sensing arrays, sampling data at more than 1 Hz. This inevitably results in large volumes of data, much of which may be redundant. Our study aimed at evaluating the optimal number of sensors and acquisition frequency that accurately predict posture and mobility during lying. A continuous pressure monitor (ForeSitePT, Xsensor, Calgary, Canada), with 5664 sensors sampling at 1 Hz, was used to assess the interface pressures of healthy volunteers who performed lying postures on two different mattresses (foam and air designs). These data were down sampled in the spatial and temporal domains. For each configuration, pressure parameters were estimated and the area under the Receiver Operating Characteristic curve (AUC) was used to determine their ability in discriminating postural change events. Convolutional Neural Network (CNN) was employed to predict static postures. There was a non-linear decline in AUC values for both spatial and temporal down sampling. Results showed a reduction of the AUC for acquisition frequencies lower than 0.3 Hz. For some parameters, e.g., pressure gradient, the lower the sensors number the higher the AUC. Posture prediction showed a similar accuracy of 63−71% and 84−87% when compared to the commercial configuration, on the foam and air mattress, respectively. This study revealed that accurate detection of posture and mobility events can be achieved with a relatively low number of sensors and sampling frequency.