Karin Bieske

Dr. Karin Bieske


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2023 in Clocks & Sleep
Verified
Journal Article
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
KBKai Broszio
Kai Broszio
KBKarin Bieske
Karin Bieske
The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular field of view (FOV) is not a perfect hemisphere, as it is occluded both upward and downward. Previous research on FOV-restricted measurements is limited, leaving the error from using hemispheric measurements for non-visual quantities undefined. In our study, we tackled this issue by designing and 3D printing FOV occlusions as attachments to spectral measurement devices. We took measurements with and without the occlusion in various laboratory (light from different directions) and real-world lighting situations (light typically from above). Our findings reveal a reduction of visual and melanopic values due to the FOV occlusion. These ranged from negligible to more than 60% in realistic scenarios. Interestingly, the reduction was consistent for both visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. An exception occurred in a specific artificial laboratory situation, where the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 solely because of the FOV occlusion. Additionally, we observed that head orientation had a marked effect on all quantities measured. In conclusion, our results highlight the potential for substantial errors when solely relying on vertical, hemispheric measurements in experiments and non-visual lighting design projects. We encourage the (additional) use of FOV occlusion in eye-level measurements for typical viewing directions, and we are providing open-source 3D-print files to facilitate this practice.

14 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
KBKai Broszio
Kai Broszio
KBKarin Bieske
Karin Bieske
Spectrally weighed irradiance on the corneal plane is often used to determine the visual and non-visual potency of light. Spectral irradiance or illuminance is measured with a diffuser in the so-called 2π geometry (i.e., a hemispheric measurement). Due to anatomical conditions, the human binocular field of view (FOV) does not correspond to a hemisphere but is occluded upwards and downwards. FOV-restricted measurements are scarce, however, and thus the error when using hemispheric measurements is yet to be determined. For our study, we designed and 3D printed FOV occlusions as attachments to spectral measurement devices. Measurements with and without the occlusion were taken in different lighting situations in the laboratory (light from different directions) and in real-world conditions (light typically from above). Our measurements show a reduction of visual and melanopic values due to the FOV occlusion ranging from negligible to over 60% for realistic scenarios. Further, the reduction was comparable for visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. In the case of an exemplary and artificial laboratory situation, however, the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 only due to the FOV occlusion. Finally, head orientation showed a marked impact on all quantities. Our results reveal the potential for considerable error when just evaluating and comparing vertical, hemispheric measurements in experiments and non-visual lighting design projects. We thus encourage the (additional) use of a FOV occlusion for eye-level measurements in typical viewing directions and provide open-source 3D-print files.