Johannes Zauner

Dr. Johannes Zauner

Department of Sport and Health Sciences, Technical University of Munich, Munich, Bavaria, Germany
+2
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2025 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
SHSteffen Hartmeyer
Steffen Hartmeyer
Manuel SpitschanManuel Spitschan
Manuel Spitschan
Light plays an important role in human health and well-being, which necessitates the study of the effects of personal light exposure in real-world settings, measured by means of wearable devices. A growing number of studies incorporate these kinds of data to assess associations between light and health outcomes. Yet with few or missing standards, guidelines, and frameworks, it is challenging setting up measurements, analysing the data, and comparing outcomes between studies. Overall, time series data from wearable light loggers are significantly more complex compared to controlled stimuli used in laboratory studies. In this paper, we introduce LightLogR, a novel resource to facilitate these research efforts. The package for R statistical software is open-source and permissively MIT-licenced. As part of a developing software ecosystem, LightLogR is built with common challenges of current and future datasets in mind. The package standardises many tasks for importing and processing personal light exposure data. It allows for quick as well as detailed insights into the datasets through summary and visualisation tools. Furthermore, LightLogR incorporates major metrics commonly used in the field (61 metrics across 17 metric families), all while embracing an inherently hierarchical, participant-based data structure.

29 August 2023 in Clocks & Sleep
Verified
Journal Article
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
KBKai Broszio
Kai Broszio
KBKarin Bieske
Karin Bieske
The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular field of view (FOV) is not a perfect hemisphere, as it is occluded both upward and downward. Previous research on FOV-restricted measurements is limited, leaving the error from using hemispheric measurements for non-visual quantities undefined. In our study, we tackled this issue by designing and 3D printing FOV occlusions as attachments to spectral measurement devices. We took measurements with and without the occlusion in various laboratory (light from different directions) and real-world lighting situations (light typically from above). Our findings reveal a reduction of visual and melanopic values due to the FOV occlusion. These ranged from negligible to more than 60% in realistic scenarios. Interestingly, the reduction was consistent for both visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. An exception occurred in a specific artificial laboratory situation, where the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 solely because of the FOV occlusion. Additionally, we observed that head orientation had a marked effect on all quantities measured. In conclusion, our results highlight the potential for substantial errors when solely relying on vertical, hemispheric measurements in experiments and non-visual lighting design projects. We encourage the (additional) use of FOV occlusion in eye-level measurements for typical viewing directions, and we are providing open-source 3D-print files to facilitate this practice.

25 October 2024 in Clocks & Sleep
Verified
Journal Article
Open access
PDF file
OSOliver Stefani
Oliver Stefani
RMReto Marek
Reto Marek
JSJürg Schwarz
Jürg Schwarz
SPSina Plate
Sina Plate
Johannes ZaunerJohannes Zauner
Johannes Zauner
BSBjörn Schrader
Björn Schrader
Understanding user challenges with light dosimeters is crucial for designing more acceptable devices and advancing light exposure research. We systematically evaluated the usability and acceptability of a light dosimeter (lido) with 29 participants who wore the dosimeter near the corneal plane of the eye for 5 days. Common reasons for not wearing the dosimeter included exercise, recharging, wet environments, public places, and discomfort. Despite these issues, participants adhered to using the dosimeter with high compliance (89% of recording time). Our findings revealed a significant discrepancy between mean (300 lxmEDI) and median (51 lxmEDI) melanopic equivalent daylight illuminance. This discrepancy indicates that the participants were exposed to significantly lower light levels most of the time. Specifically, participants were exposed to light levels above 250 lxmEDI for only 14% of their wearing time. This highlights the need for increased exposure to recommended light levels. In the evening, participants were exposed to less than the recommended 10 lxmEDI for 58% of their wearing time, which is in line with the guidelines for reducing light exposure before sleep. This study highlights the urgent need for strategies to increase daily light exposure that are more in line with circadian health recommendations.

3 December 2025 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Open access
PDF file
ABAnna M. Biller
Anna M. Biller
Johannes ZaunerJohannes Zauner
Johannes Zauner
Christian CajochenChristian Cajochen
Christian Cajochen
MGMarisa A. Gerle
Marisa A. Gerle
VKVineetha Kalavally
Vineetha Kalavally
Manuel SpitschanManuel Spitschan
Manuel Spitschan
Background: Light synchronises the internal clock with the external light-dark cycle. Keeping this alignment benefits health and prevents diseases. Quantifying light exposure is, therefore, vital for effective prevention. Objective: Since light exposure depends on photoperiod, culture, and behaviour, we investigated objective light exposure and individual light-related behaviour in Switzerland and Malaysia. Methods: In this observational field study, participants ( N = 39) wore a calibrated melanopic light logger at chest level for 30 consecutive days. At baseline and study end, the Pittsburgh Sleep Quality Index was assessed, and every 3 to 4 days, the Light Exposure Behaviour Assessment (LEBA) was filled. Results: Our pre-registered analyses reveal that participants in Switzerland experienced brighter days (+3.16 times the average mel EDI) and spent more time (x1.9 times the duration) in daylight levels per hour of daylight, had ~1.5 h later bright light exposure in the afternoon, and stayed over 1 h longer in dim light conditions before bedtime. LEBA scores did not differ between Malaysia and Switzerland, and LEBA items were stable over time. LEBA items also correlated with objective light exposure variables in Switzerland but not Malaysia, with a medium effect size (range of absolute r = 0.32–0.48). Significance: Our results highlight cultural and geographical differences in light exposure. We showed that subjective assessment of light-exposure behaviour can be related to actual light exposure and is ecologically informative, but this varies by culture. Impact: Light is a key environmental factor shaping human health, yet real-world exposure varies widely across geography and culture. In this study, we compared physiologically-relevant light exposure and self-reported light-related behaviour between Switzerland and Malaysia over a 30 day period using wearable sensors and questionnaires. We found that participants in Switzerland experienced brighter days and darker evenings than those in Malaysia, even after accounting for differences in photoperiod length. These differences reflect how climate, culture, and behaviour influence light exposure patterns. Our findings highlight the need to consider cultural and environmental context when developing recommendations and interventions to promote healthy light exposure in everyday life.

11 December 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
LULjiljana Udovicic
Ljiljana Udovicic
MSManuel Spitschan
Manuel Spitschan
Background: Light exposure regulates the human circadian system and more widely affects health, well-being, and performance. With the rise in field studies on light exposure’s effects, the amount of data collected through wearable loggers and dosimeters has also grown. These data are more complex than stationary laboratory measurements. Determining sample sizes in field studies is challenging, as the literature shows a wide range of sample sizes (between 2 and 1,887 from a recent review of the field and approaching 105 participants in first studies using large-scale ‘biobank’ databases). Current decisions on sample size for light exposure data collection lack a specific basis rooted in power analysis. Therefore, there is a need for clear guidance on selecting sample sizes. Methods: Here, we introduce a novel procedure based on hierarchical bootstrapping for calculating statistical power and required sample size for wearable light and optical radiation logging data and derived summary metrics, taking into account the hierarchical data structure (mixed-effects model) through stepwise resampling. Alongside this method, we publish a dataset that serves as one possible basis to perform these calculations: one week of continuous data in winter and summer, respectively, for 13 early-day shift-work participants (collected in Dortmund, Germany; lat. 51.514° N, lon. 7.468° E). Results: Applying our method on the dataset for twelve different summary metrics (luminous exposure, geometric mean, and standard deviation, timing/time above/below threshold, mean/midpoint of darkest/brightest hours, intradaily variability) with a target comparison across winter and summer, reveals required sample sizes ranging from as few as 3 to more than 50. About half of the metrics–those that focus on the bright time of day–showed sufficient power already with the smallest sample. In contrast, metrics centered around the dark time of the day and daily patterns required higher sample sizes: mean timing of light below mel EDI of 10 lux (5), intradaily variability (17), mean of darkest 5 hours (24), and mean timing of light above mel EDI of 250 lux (45). The geometric standard deviation and the midpoint of the darkest 5 hours lacked sufficient power within the tested sample size. Conclusions: Our novel method provides an effective technique for estimating sample size in light exposure studies. It is specific to the used light exposure or dosimetry metric and the effect size inherent in the light exposure data at the basis of the bootstrap. Notably, the method goes beyond typical implementations of bootstrapping to appropriately address the structure of the data. It can be applied to other datasets, enabling comparisons across scenarios beyond seasonal differences and activity patterns. With an ever-growing pool of data from the emerging literature, the utility of this method will increase and provide a solid statistical basis for the selection of sample sizes.

22 September 2025 in Open Research Europe
Verified
Journal Article
Open access
Johannes ZaunerJohannes Zauner
Johannes Zauner
ABAnna M. Biller
Anna M. Biller
Manuel SpitschanManuel Spitschan
Manuel Spitschan
Background Light exposure plays a crucial role in human health, influencing sleep, circadian rhythms, and visual development. As wearable light loggers are increasingly used to monitor real-world light exposure, their design must balance metrological accuracy with comfort and usability. Methods We assessed the perceived wearability and appeal of eight light logger designs and placements (chest pin, wrist, necklace, sleeve collar, collar pin, neck loop, hat pin, and glasses) using an online survey completed by 145 participants (mean age 32 years, 52% female) from the UK, USA, and other countries worldwide. Each design was rated on overall attractiveness, likelihood of wear at home, at work, in public settings, in social contexts, during exercise, expected wear duration, and perceived interference with daily activities. Results The chest pin received the highest overall ratings, followed by wrist and necklace, while glasses and hat pin placements were rated lowest across most contexts. Likelihood of wear was highest in the home setting and significantly lower in social (β = –0.92 ± 0.08) and work (β = –0.84 ± 0.08) contexts. Compared to the chest pin, other placements were rated up to 2.6 points lower (e.g., glasses: β = –2.62 ± 0.10). Wearing position significantly influenced all ratings (p < 0.001), while sample location and gender showed minimal effects. The thematic analysis of free-text responses revealed concerns around comfort, appearance, stability, and interference with daily activities. Conclusions These findings highlight the importance of user-centred design and offer practical guidance for wearable light loggers that are acceptable in everyday contexts.