Kai Broszio

Kai Broszio

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2019 in LEUKOS
Verified
Journal Article
Open access
MKMartine Knoop
Martine Knoop
KBKai Broszio
Kai Broszio
ADAicha Katarzyna Diakite-Kortlever
Aicha Katarzyna Diakite-Kortlever
CLCarolin Liedtke
Carolin Liedtke
MNMathias Niedling
Mathias Niedling
NWNils Weber
Nils Weber
Research indicates that spectral distribution and the direction of the light received at the eye are relevant parameters in studies looking into non-image-forming effects. Nonetheless, lighting conditions are often described with vertical illuminance at the eye and correlated color temperature only, both of which are integral measurements that are not appropriate to give information about the spatial distribution of light and its spectrum. This article describes approaches for spatially and spectrally resolved measurements to properly quantify lighting conditions in research on non-image-forming effects. The overview of measuring methods indicates that the spectral irradiance, when combined with a luminance image of the lighting setting, is an adequate measure in a large number of research approaches. Nonetheless, lighting conditions in experimental setups with different light sources or various surface reflectances require a higher resolution of detail. Four examples of devices are presented that can be applied in different experimental setups or lighting settings. A decision scheme is included to support the selection of the most suitable measuring equipment. The article concludes with a proposal for analysis and representation of the measurements.

29 August 2023 in Clocks & Sleep
Verified
Journal Article
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
KBKai Broszio
Kai Broszio
KBKarin Bieske
Karin Bieske
The visual and non-visual effectiveness of light is often determined by measuring the spectrally weighed irradiance on the corneal plane. This is typically achieved using spectral irradiance or illuminance measurements, captured in a hemispheric (2π) geometry with a diffuser. However, the human binocular field of view (FOV) is not a perfect hemisphere, as it is occluded both upward and downward. Previous research on FOV-restricted measurements is limited, leaving the error from using hemispheric measurements for non-visual quantities undefined. In our study, we tackled this issue by designing and 3D printing FOV occlusions as attachments to spectral measurement devices. We took measurements with and without the occlusion in various laboratory (light from different directions) and real-world lighting situations (light typically from above). Our findings reveal a reduction of visual and melanopic values due to the FOV occlusion. These ranged from negligible to more than 60% in realistic scenarios. Interestingly, the reduction was consistent for both visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. An exception occurred in a specific artificial laboratory situation, where the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 solely because of the FOV occlusion. Additionally, we observed that head orientation had a marked effect on all quantities measured. In conclusion, our results highlight the potential for substantial errors when solely relying on vertical, hemispheric measurements in experiments and non-visual lighting design projects. We encourage the (additional) use of FOV occlusion in eye-level measurements for typical viewing directions, and we are providing open-source 3D-print files to facilitate this practice.

1 April 2018 in Light & Engineering
Verified
Journal Article
Closed access
KBKai Broszio
Kai Broszio
MKMartine Knoop
Martine Knoop
MNMathias Niedling
Mathias Niedling
SVStephan Völker
Stephan Völker
Research indicates that intrinsically photosensitive Retinal Ganglion Cells are not evenly distributed or evenly sensitive throughout the retina. Still, most research looking into non-image forming (NIF) effects uses an integral measured quantity, illuminance or melanopic weighted irradiance, to represent the amount of light at the participantsХ eye level. This paper describes a theoretical approach to define the effective radiant flux for stimulating the ipRGCs, taking into account a spatially resolved sensitivity. Research on retinal sensitivity is scares and not yet substantial, but the methodology can easily be adopted when areas of specific sensitivity are set. Preliminary results indicate that, with similar vertical illuminances and spectral power distribution, typical office lighting solutions might have a lower NIF effectiveness than settings with higher luminances in the central part of the field of view. This could explain why research on NIF effects is inconclusive, even though reported lighting conditions are similar.

29 January 2026 in BMC Medicine
Verified
Journal Article
Open access
PDF file
Manuel SpitschanManuel Spitschan
Manuel Spitschan
ABAnna M. Biller
Anna M. Biller
KBKai Broszio
Kai Broszio
EFElaine Fischer
Elaine Fischer
Janice HegewaldJanice Hegewald
Janice Hegewald
Johannes ZaunerJohannes Zauner
Johannes Zauner
Background: Light exposure over 24 h is a modifiable environmental influence on human physiology and behavior with significant implications for health and well-being, yet the field lacks coordinated research infrastructure, standardized methodologies, and translational pathways. Methods: To address this, we convened a multi-disciplinary consensus workshop and expert consultation process with 13 experts from academia, public health, radiation protection, and occupational health institutions. The aim was to identify key research gaps and to define priority areas to guide future work. Results: Through an in-person and hybrid meeting, followed by iterative refinement and feedback, we identified nine critical gaps: (1) lack of standardized measurement tools, (2) inadequate exposure estimation infrastructure, (3) inconsistent descriptors and metrics, (4) absence of outcome standards, (5) limited dose–response evidence beyond the laboratory, (6) insufficient data on intervention effectiveness, (7) poor characterization of globally representative and vulnerable populations, (8) fragmented data harmonization, and (9) limited integration into public health frameworks. To address these gaps, we propose 11 research priority areas spanning measurement, methodology, data infrastructure, ethics, and implementation, as well as four capacity-building priority areas. Conclusions: This agenda provides a strategic foundation for building an integrated and evidence-based approach to studying and understanding light exposure as a determinant of health.

13 February 2024 in medRxiv
Verified
Preprint
Open access
PDF file
CGCarolina Guidolin
Carolina Guidolin
Sam AertsSam Aerts
Sam Aerts
GAGabriel Kwaku Agbeshie
Gabriel Kwaku Agbeshie
KAKwadwo Owusu Akuffo
Kwadwo Owusu Akuffo
SASema Nur Aydin
Sema Nur Aydin
Manuel SpitschanManuel Spitschan
Manuel Spitschan
Light profoundly impacts many aspects of human physiology and behaviour, including the synchronization of the circadian clock, the production of melatonin, and cognition. These effects of light, termed the non-visual effects of light, have been primarily investigated in laboratory settings, where light intensity, spectrum and timing can be carefully controlled to draw associations with physiological outcomes of interest. Recently, the increasing availability of wearable light loggers has opened the possibility of studying personal light exposure in free-living conditions where people engage in activities of daily living, yielding findings associating aspects of light exposure and health outcomes, supporting the importance of adequate light exposure at appropriate times for human health. However, comprehensive protocols capturing environmental (e.g., geographical location, season, climate, photoperiod) and individual factors (e.g., culture, personal habits, behaviour, commute type, profession) contributing to the measured light exposure are currently lacking. Here, we present a protocol that combines smartphone-based experience sampling (experience sampling implementing Karolinska Sleepiness Scale, KSS ratings) and high-quality light exposure data collection at three body sites (near-corneal plane between the two eyes mounted on spectacle, neck-worn pendant/badge, and wrist-worn watch-like design) to capture daily factors related to individuals’ light exposure. We will implement the protocol in an international multi-centre study to investigate the environmental and socio-cultural factors influencing light exposure patterns in Germany, Ghana, Netherlands, Spain, Sweden, and Turkey (minimum n=15, target n=30 per site, minimum n=90, target n=180 across all sites). With the resulting dataset, lifestyle and context-specific factors that contribute to healthy light exposure will be identified. This information is essential in designing effective public health interventions.

14 June 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Johannes ZaunerJohannes Zauner
Johannes Zauner
KBKai Broszio
Kai Broszio
KBKarin Bieske
Karin Bieske
Spectrally weighed irradiance on the corneal plane is often used to determine the visual and non-visual potency of light. Spectral irradiance or illuminance is measured with a diffuser in the so-called 2π geometry (i.e., a hemispheric measurement). Due to anatomical conditions, the human binocular field of view (FOV) does not correspond to a hemisphere but is occluded upwards and downwards. FOV-restricted measurements are scarce, however, and thus the error when using hemispheric measurements is yet to be determined. For our study, we designed and 3D printed FOV occlusions as attachments to spectral measurement devices. Measurements with and without the occlusion were taken in different lighting situations in the laboratory (light from different directions) and in real-world conditions (light typically from above). Our measurements show a reduction of visual and melanopic values due to the FOV occlusion ranging from negligible to over 60% for realistic scenarios. Further, the reduction was comparable for visual and melanopic parameters, as the distribution of light in the FOV was generally spectrally homogeneous. In the case of an exemplary and artificial laboratory situation, however, the melanopic daylight (D65) efficacy ratio changed by more than a factor of 2 only due to the FOV occlusion. Finally, head orientation showed a marked impact on all quantities. Our results reveal the potential for considerable error when just evaluating and comparing vertical, hemispheric measurements in experiments and non-visual lighting design projects. We thus encourage the (additional) use of a FOV occlusion for eye-level measurements in typical viewing directions and provide open-source 3D-print files.