Ying He

Prof. Dr. Ying He


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
YHYangkun Huang
Yangkun Huang
Ying HeYing He
Ying He
Shunda QiaoShunda Qiao
Shunda Qiao
HSHaiyue Sun
Haiyue Sun
Yufei MaYufei Ma
Yufei Ma
Photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and light-induced thermoelastic spectroscopy (LITES) represent indirect absorption spectroscopy techniques for trace gas sensing, whose performance has long been advanced through hardware-oriented enhancement strategies. However, as hardware technologies continue to advance, conventional hardware-based enhancements are increasingly bottlenecked by weak responses, complex cross-interferences, and coupled multiphysics parameters. To transcend these limitations, algorithm-assisted methods, including traditional algorithms, machine learning, deep learning, and intelligent optimization, are being systematically integrated into these spectroscopic systems. This review summarizes recent progress in intelligent indirect absorption spectroscopy from three interconnected dimensions. First, we outline advanced signal processing and spectral reconstruction strategies designed to achieve weak-signal recovery and background noise suppression. Second, the focus shifts to data-driven parameter inversion, showing how multidimensional artificial intelligence models contribute to concentration retrieval, environmental compensation, multicomponent recognition, spectral-overlap decoupling, and front–back-end collaborative waveform coding and demultiplexing. Third, intelligent system optimization is examined, in which surrogate modeling, swarm-intelligence search, physics-guided topology optimization and multi-objective algorithms are employed to improve the design efficiency of the key elements such as photoacoustic resonators and multipass cells (MPCs). Additionally, prospects for future technological developments are also discussed in the concluding section.

4 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
WYWang Yuanzhi
Wang Yuanzhi
Ying HeYing He
Ying He
Shunda QiaoShunda Qiao
Shunda Qiao
Xiaoming DuanXiaoming Duan
Xiaoming Duan
Yufei MaYufei Ma
Yufei Ma
In this paper, a highly sensitive methane (CH4) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H2) and helium (He) enhancement techniques are reported for the first time. The low resonant frequency self-designed T-shaped QTF was exploited for improving the energy accumulation time. H2 and He were utilized as surrounding gases for the T-shaped QTF to minimize energy loss, thereby enhancing the sensitivity of the LITES sensor. Additionally, a fiber-coupled multi-pass cell (FC-MPC) with a 40 m optical length was utilized to improve the optical absorption of CH4. The frequency response of the T-shaped QTF with different concentrations of H2 and He was investigated, and the Q factor in the H2 and He environment increased significantly. Compared to operating QTF in a nitrogen (N2) environment, the signal amplitude was enhanced by 2.9 times and 1.9 times in pure H2 and He environments, respectively. This enhancement corresponded to a minimum detection limit (MDL) of 80.3 ppb and 113.6 ppb. Under different CH4 concentrations, the T-shaped QTF-based H2-enhanced CH4-LITES sensor showed an excellent linear response. Furthermore, through Allan deviation analysis, the MDL of the T-shaped QTF-based H2-enhanced CH4-LITES can reach 38 ppb with an 800 s integration time.

27 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
JMJunjie Mu
Junjie Mu
JHJinfeng Hou
Jinfeng Hou
SQShaoqi Qiu
Shaoqi Qiu
Shunda QiaoShunda Qiao
Shunda Qiao
Ying HeYing He
Ying He
Yufei MaYufei Ma
Yufei Ma
A carbon dioxide (CO2) sensor based on light-induced thermoelastic spectroscopy (LITES) using a 2 μm diode laser and a self-designed low-frequency trapezoidal-head QTF is reported for the first time in this invited paper. The self-designed trapezoidal-head QTF with a low resonant frequency of 9464.18 Hz and a high quality factor (Q) of 12,133.56 can significantly increase the accumulation time and signal level of the CO2-LITES sensor. A continuous-wave (CW) distributed-feedback (DFB) diode laser is used as the light source, and the strongest absorption line of CO2 located at 2004.01 nm is chosen. A comparison between the standard commercial QTF with the resonant frequency of 32.768 kHz and the self-designed trapezoidal-head QTF is performed. The experimental results show that the CO2-LITES sensor with the self-designed trapezoidal-head QTF has an excellent linear response to CO2 concentration, and its minimum detection limit (MDL) can reach 46.08 ppm (parts per million). When the average time is increased to 100 s based on the Allan variance analysis, the MDL of the sensor can be improved to 3.59 ppm. Compared with the 16.85 ppm of the CO2-LITES sensor with the commercial QTF, the performance is improved by 4.7 times, demonstrating the superiority of the self-designed trapezoidal-head QTF.

5 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
HMHanxu MA
Hanxu MA
Shunda QiaoShunda Qiao
Shunda Qiao
Ying HeYing He
Ying He
Yufei MaYufei Ma
Yufei Ma
A highly sensitive light-induced thermoelastic spectroscopy (LITES) sensor employing a charge amplifier (CA) is reported for the first time in this invited paper. CA has the merits of high input impedance and strong anti-interference ability. The usually used transimpedance amplifier (TA) and voltage amplifier (VA) were also studied under the same conditions for comparison. A standard commercial quartz tuning fork (QTF) with a resonant frequency of approximately 32.76 kHz was used as the photothermal signal transducer. Methane (CH4) was used as the target gas in these sensors for performance verification. Compared to the TA-LITES sensor and VA-LITES sensor, the reported CA-LITES sensor shows improvements of 1.83 times and 5.28 times in the minimum detection limit (MDL), respectively. When compared to the LITES sensor without an amplifier (WA-LITES), the MDL has a 19.96-fold improvement. After further optimizing the gain of the CA, the MDL of the CA-LITES sensor was calculated as 2.42 ppm, which further improved the performance of the MDL by 30.3 times compared to the WA-LITES. Additionally, long-term stability is analyzed using Allan deviation analysis. When the average time of the sensor system is increased to 50 s, the MDL of the CA-LITES sensor system can be improved to 0.58 ppm.

9 July 2026 in eLight
Verified
Journal Article
Open access
PDF file
CGChenzi Guo
Chenzi Guo
Ying HeYing He
Ying He
TLTianfu Li
Tianfu Li
Yufei MaYufei Ma
Yufei Ma
YDYongkang Dong
Yongkang Dong

30 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CJCai Jingze
Cai Jingze
YCYanjun Chen
Yanjun Chen
HMHanxu Ma
Hanxu Ma
Shunda QiaoShunda Qiao
Shunda Qiao
Ying HeYing He
Ying He
Yufei MaYufei Ma
Yufei Ma
In the paper, a heterodyne quartz-enhanced photoacoustic spectroscopy (H-QEPAS)-based integrated methane (CH4) sensor prototype is reported. The CH4 absorption line located at 1650.96 nm was selected as the target spectral line. The design features an integrated, 3D-printed gas chamber for reduced size and weight. To realize the coordinated operation of each hardware component, a control program was designed based on LabVIEW platform, enabling the adjustment of various hardware parameters. The piezoelectric signal generated by the quartz tuning fork (QTF) was amplified via a trans-impedance amplifier (TIA), acquired by a data acquisition card (DAQ), and then transmitted to a virtual lock-in amplifier (LIA) on the PC terminal for processing. The dimensions of the integrated CH4 sensor prototype are 33 cm in length, 27 cm in width, and 15 cm in height. The final test results demonstrate that the sensor prototype exhibits an excellent concentration linear response, with a detection limit of 26.72 ppm and a short detection time of approximately 4 s.