Jiancun Liu

Dr. Jiancun Liu


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
KSKaitao Sun
Kaitao Sun
Jiancun LiuJiancun Liu
Jiancun Liu
CQChao Qin
Chao Qin
XCXi Chen
Xi Chen
With the development of distribution networks, the widespread use of communication devices has exposed these networks to the risk of cross-domain attacks. Based on the coupling relationship between power and communication networks, a method for the optimal allocation of distribution network resources considering this coupling is proposed. In the resource allocation stage, given the limited availability of resources, optimal allocation is carried out for resources such as distributed generations and remote-controlled switches; additionally, the resilience of the distribution network is enhanced through the reinforcement of both the distribution lines and communication links. In the prevention stage, in advance of extreme events, preventive islanding is formed through switch operations. In the degradation stage, the distribution network identifies faulted and non-faulted areas based on the fault propagation model, while the communication network assesses the fault status of communication nodes based on the virtual flow model. In the recovery stage, coordinated control of remote-controlled switches and distributed generations with normal communication is implemented for network reconfiguration to minimize load losses. Finally, the effectiveness of the proposed method is verified through the IEEE 33-node system.

9 March 2025 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
XZXiaolong Zhao
Xiaolong Zhao
ZYZheng Yang
Zheng Yang
MZMeiling Zheng
Meiling Zheng
YWYajuan Wang
Yajuan Wang
YNYaming Nan
Yaming Nan
JGJiaming Gao
Jiaming Gao

26 September 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
Jiancun LiuJiancun Liu
Jiancun Liu
PLPengfei Li
Pengfei Li
JRJUNZHI REN
JUNZHI REN
DZDe long Zhang
De long Zhang
XZXuesong Zhou
Xuesong Zhou
The resilience and sustainable development of modern power distribution systems faces escalating challenges due to increasing renewable integration and extreme events. Traditional single-system approaches often overlook the spatiotemporal coordination of cross-domain restoration resources. In this paper, we propose a multi-stage resilience enhancement method that employs transportation and hydrogen energy systems. This approach coordinates the pre-event preventive allocation and multi-stage collaborative scheduling of diverse restoration resources, including remote-controlled switches (RCSs), mobile hydrogen emergency resources (MHERs), and hydrogen production and refueling stations (HPRSs). The proposed framework supports cross-stage dynamic optimization scheduling, enabling the development of adaptive resource dispatch strategies tailored to the characteristics of different stages, including prevention, fault isolation, and service restoration. The model is applicable to complex scenarios involving dynamically changing network topologies and is formulated as a mixed-integer linear programming (MILP) problem. Case studies based on the IEEE 33-bus system show that the proposed method can restore a distribution system’s resilience to approximately 87% of its normal level following extreme events.

13 November 2025 in Energies
Verified
Journal Article
Open access
PDF file
SPSichao Pan
Sichao Pan
YYYue Yang
Yue Yang
RARanran An
Ranran An
XLXiaobing Liang
Xiaobing Liang
WYWenlong Yang
Wenlong Yang
Jiancun LiuJiancun Liu
Jiancun Liu
Installing energy storage devices can improve the frequency modulation ability of offshore wind farms to participate in the grid. The lifecycle and wear of energy storage devices are significantly influenced by ambient temperature, charge and discharge rates, cycle depths, and operating environments. To extend the lifecycle and reduce the replacement frequency of these devices, their operation mode must be carefully considered. However, existing energy storage optimization configurations rarely consider these factors, particularly when addressing the frequency stability of offshore wind power systems. To address this gap, an optimization method is proposed for energy storage allocation that incorporates system frequency support, energy storage cost, and the devices’ lifecycle and degradation. This approach ensures a reasonable and efficient allocation of energy storage.

20 September 2026 in Energies
Verified
Journal Article
Open access
PDF file
SHShuonan Hou
Shuonan Hou
LXLu Xinyun
Lu Xinyun
ZSZHENGWEI SHEN
ZHENGWEI SHEN
XZXiaopei Zhang
Xiaopei Zhang
Jiancun LiuJiancun Liu
Jiancun Liu
Extreme events threaten distribution network security. When remote-controlled switches (RCSs) lose remote operability during extreme events while remaining manually operable, faulted areas may no longer be isolated through remote switching alone. This paper proposes a multi-stage resilience enhancement method that coordinates RCSs and switch operation crews under RCS fault conditions. A four-stage framework is established, comprising pre-event prevention, degradation, fault isolation, and service restoration. Normal RCSs can be remotely opened to shrink the faulted zone during isolation, while faulty RCSs remain frozen and can change their switching states only through on-site crew intervention during restoration. A unified operation constraint is formulated for the isolation stage, and a crew-assisted switching constraint links crew presence at faulty-RCS locations to their switching operability during restoration. The problem is cast as a scenario-based mixed-integer linear program minimizing expected weighted load shedding across all post-event stages. Case studies on the modified IEEE 33-bus system demonstrate the effectiveness of the proposed method under different RCS availability conditions. Under the same line-fault configuration, loss of RCS remote operability increases cumulative weighted load shedding by 28.09% and delays complete load restoration by one time interval. The reported four-scenario computation required approximately 7128 s.