This paper presents a detailed comparison of eliminated and non-eliminated harmonics for 3-level, 5-level and 13-level cascaded multilevel inverter. For this research, three different types of cascaded H-Bridge multilevel inverters are considered where each cascaded multilevel inverter generates a different output voltage, but the number of notch angles in all the three cases are kept identical. A unified approach is adopted to derive the mathematical model of each multilevel inverter output voltage waveform, RMS of output voltage, RMS of fundamental component, selective harmonic elimination system of equations for the low order harmonics elimination and output voltage total harmonic distortion. It is shown that since selective harmonic elimination system of equations can be expressed as a function of the notch angles, hence notch angles are determined while taking in account only those harmonics to be eliminated. The Newton-Raphson method is proposed to resolve the nonlinear transcendental equations of selective harmonic elimination for the three multilevel inverter cases. Consequently, once the notch angles are determined, all three multilevel inverters are analyzed by comparing Total Harmonic Distortion and Zero-Sequence Harmonics Factor. The elimination of triplen-harmonics by evaluating them in the non-linear transcendental system of equations is a significant contribution. The theoretical and simulated results are presented to verify the validity of the proposed work.
This paper presents a novel tetra-level dynamic decomposition-based control approach for coordinated operation of electric vehicles in multimicrogrids, which is comprehensive, generic, modular, and secure in nature, to maximize the utilization of renewable energy sources, while meeting the load demands with the resources available. There are a number of microgrids that are connected to the grid. Each microgrid consists of a number of renewable energy sources, energy storage systems, non-renewable energy sources, electric vehicles, and loads. Each distributed energy source or load is controlled by a microsource controller. All microsource controllers with a similar nature are controlled by a unit controller, and all the unit controllers in a microgrid are controlled by a microgrid controller. There is a single multimicrogrid controller at the top. The proposed control scheme was verified through simulation-based case studies.
This paper proposes a novel decomposition based hierarchical heuristic control of multimicrogrids to maximize the utilization of renewable energy sources and load satisfaction. The proposed control is capable of providing comprehensive online dispatch of active and reactive powers in steady state modes of operation according to IEEE 2030.7 while keeping in view the restrictions of the participants (microsources and/or microgrids). The proposed solution is generalized to be adopted with respect to different types of participants and grid structures, modular with respect to the number of its participants and capable of protecting the privacy of its participants to maximum possible extent. The proposed heuristic control decomposes the control problem at four levels of hierarchy namely microsource, unit, microgrid and multimicrogrid level. All the distributed energy sources have their own microsource controllers and all the distributed energy sources of the same type are put under one unit controller. All the unit controllers are put under a microgrid controller and all the microgrid controllers are put under a multimicrogrid controller. Information flows from lower to upper levels while dispatch commands flow vice versa. This provides a comprehensive, generic, modular and secure control of a multimicrogrid system. Test cases are simulated to verify the validity of the proposed control scheme.
23 July 2025 in UCP Journal of Engineering & Information Technology
Wireless power transfer has evolved as a dominant research field. Roadway-powered vehicles have poor and fluctuating efficiency due to varying coupling coefficients because of their dynamic nature. Efficiency improvement efforts become useless in the event of communication failure between the transmitter and receiver sides. This paper presents a novel algorithm based on a silent handshake between the two sides to achieve the most efficient operation with varying flux linkage. The timed sequence of operations enables the continuous load mapping by impedance matching converter to maximize the efficiency followed by load regulation done by the supply converter based on accurate mathematical modelling. Simulation and experimental results are presented to ascertain the performance of the algorithm and the mathematical models.
9 January 2026 in UCP Journal of Engineering & Information Technology
Electric vehicles have emerged as an alternative way to reduce fossil fuel consumption, which is the cause of increasing environmental, economical and geopolitical problems. This paper reviews the strategies for charging electric vehicles smartly from the viewpoint of the grid. These strategies are classified into three categories. The strategies at the component level discuss the necessary aspects of batteries, their charging methods, and chargers for smart charging purposes. The strategies on the system level are discussed under the heads of unidirectional and bidirectional power flow strategies. Unidirectional power flow strategies manage the power flow from the grid to electric vehicles for their charging. The bidirectional power flow strategies, apart from charging the electric vehicles, also use their battery storage for grid support. Also, the strategies that can be deployed at the operational level are discussed. These strategies, on the one hand, tend to alleviate the stressful impacts of increasing the load of charging the electric vehicles on the grid, and on the other hand, use the energy storage capability of the electric vehicles for grid support.