Using a thermal evaporator, various porous Cu films were deposited according to the deposition pressure. CuO films were formed by post heat treatment in the air. Changes in morphological and structural characteristics of films were analyzed using field-emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD). Relative density and porosity were quantitatively calculated. CuO films with various pores ranging from 39.4 to 95.2% were successfully manufactured and were applied as gas sensors for H2S detection on interdigitated electrode (IDE) substrate. Resistance change was monitored at 325 °C and an increase in porosity of the film improved the sensor performance. The CuO-10 gas sensor with a high porosity of 95.2% showed a relatively high response (2.7) and a fast recovery time (514 s) for H2S 1.5 ppm. It is confirmed that the porosity of the CuO detection layer had a significant effect on response and recovery time.
A completely non-destructive analytical method is one of the great advantages of Raman spectroscopy. However, low efficiency of Raman signals should be improved to be widely used for detecting less than ppm of chemicals. Surface enhanced Raman scattering (SERS), which is a valuable technique for detecting the target substance very sensitively, is a method of amplifying Raman signals by the plasmon coupling effect at the gap between the nanoparticles. For this reason, materials and the nano-structure such as particle size, shape, gap and density were major factors for determining the performance of the SERS substrate. In this study, gas flow sputtering (GFS) was used for fabricating SERS substrates. The nano-porous structure was observed using scanning electron microscope (SEM) and crystal structures were also analyzed by X-ray diffraction (XRD). The density of the nano-porous structure was calculated using the thickness of the film and the mass difference before and after deposition. Silver (Ag) was widely studied as SERS substrate, due to excellent SERS effect and lower price than that of other noble metals. However, Ag has a significant degradation in SERS effect with time which appears to be a problem caused by oxidation of the Ag surface. Owing to this problem, fabricating a highly reproducible SERS substrate is a challenging issue and many researchers are conducting study. To solve this problem, Ag dense film and oxide film were sequentially deposited. Then, Ag nano-porous thin film was deposited on the oxide film to form a dielectric nano-gap between Ag dense film and Ag nano-porous thin film. Also, to protect from oxidation, Ag nano-porous thin film was coated with a thin oxide film using in-situ co-sputtering. The structure of nano-porous thin film was controlled by varying the sputtering power, time, process pressure. As a result, rhodamine 6G of less than 0.5 uM was successfully detected and it showed much improved Raman signal compared with single Ag nano-porous thin film. In addition, the aging problem, which was the most important issue, also reduced noticeably.