This paper presents the implementation, trajectory planning, kinematics, and experimental validation of an open-source 3D-printed delta robot manipulator. The robot’s hardware consists of three servo motors, an Arduino Uno microcontroller, and a Pulse Width Modulation (PWM) servo module. The software includes a trapezoidal velocity profile planner and an inverse and forward kinematics solver to calculate the motor angles required to achieve a desired end-effector position in task space. The 3D printed parts were obtained from an open-source Thingiverse project and assembled to form the robot’s kinematic structure. The robot’s performance was evaluated in terms of its accuracy, repeatability, and maximum speed for a pick-and-place task. Experimental results show that the robot can achieve a positioning accuracy of 2.2 mm, with a top speed of 0.4 m/s, 30 picks per minute, and load carrying capacity up to 200 g. These results are satisfactory, considering the ease of assembly and the cost-effectiveness of the robot. The comparison of the calculated motor angles with actual motor angles obtained through additional potentiometer wires soldering shows promising results. The proposed robot’s cost-effective characteristics, utilization of open-source additive manufacturing, and motion planning algorithms make it suitable for various applications, including education, research, and small-scale industrial applications.
CubeSats require accurate determination of their orientation relative to the Sun, Earth, and other celestial bodies to operate successfully and collect scientific data. This paper presents an orientation system based on solar and magnetic sensors that offers a cost-effective and reliable solution for CubeSat navigation. Solar sensors analyze the illumination on each face to measure the satellite’s orientation relative to the Sun, while magnetic sensors determine the Earth’s magnetic field vector in the satellite’s reference frame. By combining the measured data with the known ephemeris of the satellite, the satellite–Sun vector and the magnetic field orientation can be reconstructed. The orientation is expressed using quaternions, representing the rotation from the internal reference system of the satellite to the selected reference system. The proposed system demonstrates the ability to accurately determine the orientation of a CubeSat using only two sensors, making it suitable for installations where more complex and expensive instruments are impractical. Additionally, the paper presents a mathematical model of a low-cost CubeSat orientation system and a hardware implementation of the sensor. The technology, using solar and magnetic sensors, provides a reliable and affordable solution for CubeSat navigation, supporting the increasing sophistication of miniature payloads and enabling accurate satellite positioning in space missions.
This paper presents the development, modeling, and analysis of an autonomous active ankle prosthesis with two degrees of freedom (2-DoF), designed to reproduce movements in the sagittal (dorsiflexion/plantarflexion) and frontal (inversion/eversion) planes in order to enhance the stability and naturalness of the user’s gait. Unlike most commercial prostheses, which typically feature only one active degree of freedom, the proposed device combines a lightweight mechanical design, a screw drive with a stepper motor, and a microcontroller-based control system. The prototype was developed using CAD modeling in SolidWorks 2024, followed by dynamic modeling and finite element analysis (FEA). The simulation results confirmed the achievement of physiological angular ranges of ±20–22 deg. in both planes, with stable kinematic behavior and minimal vertical displacements. According to the FEA data, the maximum von Mises stress (1.49 × 108 N/m2) and deformation values remained within elastic limits under typical loading conditions, though cyclic fatigue and impact energy absorption were not experimentally validated and are planned for future work. The safety factor was estimated at ~3.3, indicating structural robustness. While sensor feedback and motor dynamics were idealized in the simulation, future work will address real-time uncertainties such as sensor noise and ground contact variability. The developed design enables precise, energy-efficient, and adaptive motion control, with an estimated average power consumption in the range of 7–9 W and an operational runtime exceeding 3 h per charge using a standard 18,650 cell pack. These results highlight the system’s potential for real-world locomotion on uneven surfaces. This research contributes to the advancement of affordable and functionally autonomous prostheses for individuals with transtibial amputation.
This research presents the results of conceptual design and modeling of an exoskeleton. It is intended for ankle joint rehabilitation in patients with musculoskeletal disorders. The exoskeleton design includes three screw actuators that smoothly control motion in the planes of dorsal and plantar flexion, inversion, and eversion. The results of the virtual tests performed on the exoskeleton device demonstrated a high degree of adaptability to varying loads and different phases of motion. Controlled torque fluctuations and linear motion provide the necessary support during different phases of rehabilitation, which has a positive impact on the patient’s recovery rate. The advantages of the design include material availability, ease of use, and flexibility in customization, making it an attractive option for use in both clinical and home settings. The study emphasizes the importance of developing affordable and accurate rehabilitation devices that can adapt to individual patient needs.
Affordable, sensor-driven lower-limb prostheses remain scarce in middle-income health systems. We report the design, numerical justification, and bench validation of a semi-active transfemoral prosthesis featuring surface electromyography (EMG) control and inertial sensing for low-resource deployment. The mechanical architecture combines a titanium–aluminum–carbon composite frame (total mass 0.87 kg; parts cost < USD 400) with topology optimization (SIMP) to minimize weight while preserving stiffness. Finite-element analyses (critical load 2.94 kN) confirmed structural safety (yield safety factor ≥ 1.6) and favorable fatigue margins. A dual-channel sensing scheme—surface EMG from the rectus femoris and an IMU—drives a five-state gait finite state machine implemented on a low-power STM32H platform. The end-to-end EMG→PWM latency remained <200 ms (mean 185 ms). Bench tests reproduced commanded flexion within ±2.2%, with average electrical power of ~4.6 W and battery autonomy of ~5.7 h using a 1650 mAh Li-Po pack. Results demonstrate a pragmatic trade-off between functionality and cost: semi-active damping with EMG-triggered control and open, modular hardware suitable for small-lab fabrication. Meeting target metrics (mass ≤ 1 kg, latency ≤ 200 ms, autonomy ≥ 6 h, cost ≤ USD 500), the prototype indicates a viable pathway to broaden access to intelligent prostheses and provides a platform for future upgrades (e.g., neural network control and higher-efficiency actuators).