Giada Acciaroli

Dr. Giada Acciaroli


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2017 in Electronics
Verified
Journal Article
Open access
PDF file
Giacomo CapponGiacomo Cappon
Giacomo Cappon
GAGiada Acciaroli
Giada Acciaroli
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Worldwide, the number of people affected by diabetes is rapidly increasing due to aging populations and sedentary lifestyles, with the prospect of exceeding 500 million cases in 2030, resulting in one of the most challenging socio-health emergencies of the third millennium. Daily management of diabetes by patients relies on the capability of correctly measuring glucose concentration levels in the blood by using suitable sensors. In recent years, glucose monitoring has been revolutionized by the development of Continuous Glucose Monitoring (CGM) sensors, wearable non/minimally-invasive devices that measure glucose concentration by exploiting different physical principles, e.g., glucose-oxidase, fluorescence, or skin dielectric properties, and provide real-time measurements every 1–5 min. CGM opened new challenges in different disciplines, e.g., medicine, physics, electronics, chemistry, ergonomics, data/signal processing, and software development to mention but a few. This paper first makes an overview of wearable CGM sensor technologies, covering both commercial devices and research prototypes. Then, the role of CGM in the actual evolution of decision support systems for diabetes therapy is discussed. Finally, the paper presents new possible horizons for wearable CGM sensor applications and perspectives in terms of big data analytics for personalized and proactive medicine.

13 March 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
GAGiada Acciaroli
Giada Acciaroli
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Minimally invasive continuous glucose monitoring (CGM) sensors are wearable medical devices that provide real-time measurement of subcutaneous glucose concentration. This can be of great help in the daily management of diabetes. Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a “raw” current signal via a glucose-oxidase electrochemical reaction. This electrical signal needs to be translated in real-time to glucose concentration through a calibration process. For such a scope, the first commercialized CGM sensors implemented simple linear regression techniques to fit reference glucose concentration measurements periodically collected by fingerprick. On the one hand, these simple linear techniques required several calibrations per day, with the consequent patient’s discomfort. On the other, only a limited accuracy was achieved. This stimulated researchers to propose, over the last decade, more sophisticated algorithms to calibrate CGM sensors, resorting to suitable signal processing, modelling, and machine-learning techniques. This review paper will first contextualize and describe the calibration problem and its implementation in the first generation of CGM sensors, and then present the most recently-proposed calibration algorithms, with a perspective on how these new techniques can influence future CGM products in terms of accuracy improvement and calibration reduction.

1 May 2018 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ELEnrico Longato
Enrico Longato
GAGiada Acciaroli
Giada Acciaroli
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
LHLiisa Hakaste
Liisa Hakaste
TTTiinamaija Tuomi
Tiinamaija Tuomi
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino