By providing blood glucose (BG) concentration measurements in an almost continuous-time fashion for several consecutive days, wearable minimally-invasive continuous glucose monitoring (CGM) sensors are revolutionizing diabetes management, and are becoming an increasingly adopted technology especially for diabetic individuals requiring insulin administrations. Indeed, by providing glucose real-time insights of BG dynamics and trend, and being equipped with visual and acoustic alarms for hypo- and hyperglycemia, CGM devices have been proved to improve safety and effectiveness of diabetes therapy, reduce hypoglycemia incidence and duration, and decrease glycemic variability. Furthermore, the real-time availability of BG values has been stimulating the realization of new tools to provide patients with decision support to improve insulin dosage tuning and infusion. The aim of this paper is to offer an overview of current literature and future possible developments regarding CGM technologies and applications. In particular, first, we outline the technological evolution of CGM devices through the last 20 years. Then, we discuss about the current use of CGM sensors from patients affected by diabetes, and, we report some works proving the beneficial impact provided by the adoption of CGM. Finally, we review some recent advanced applications for diabetes treatment based on CGM sensors.
16 February 2018 in Journal of Diabetes Science and Technology
Background: A new version of the UVA/Padova Type 1 Diabetes (T1D) Simulator is presented which provides a more realistic testing scenario. The upgrades to the previous simulator, which was accepted by the Food and Drug Administration in 2013, are described. Method: Intraday variability of insulin sensitivity (SI) has been modeled, based on clinical T1D data, accounting for both intra- and intersubject variability of daily SI. Thus, time-varying distributions of both subject’s basal insulin infusion and insulin-to-carbohydrate ratio were calculated and made available to the user. A model of “dawn” phenomenon based on clinical T1D data has been also included. Moreover, the model of subcutaneous insulin delivery has been updated with a recently developed model of commercially available fast-acting insulin analogs. Models of both intradermal and inhaled insulin pharmacokinetics have been included. Finally, new models of error affecting continuous glucose monitoring and self-monitoring of blood glucose devices have been added. Results: One hundred in silico adults, adolescent, and children have been generated according to the above modifications. The new simulator reproduces the intraday glucose variability observed in clinical data, also describing the nocturnal glucose increase, and the simulated insulin profiles reflect real life data. Conclusions: The new modifications introduced in the T1D simulator allow to extend its domain of validity from “single-meal” to “single-day” scenarios, thus enabling a more realistic framework for in silico testing of advanced diabetes technologies including glucose sensors, new insulin molecules and artificial pancreas.
1 August 2020 in Journal of Biomedical Informatics
Worldwide, the number of people affected by diabetes is rapidly increasing due to aging populations and sedentary lifestyles, with the prospect of exceeding 500 million cases in 2030, resulting in one of the most challenging socio-health emergencies of the third millennium. Daily management of diabetes by patients relies on the capability of correctly measuring glucose concentration levels in the blood by using suitable sensors. In recent years, glucose monitoring has been revolutionized by the development of Continuous Glucose Monitoring (CGM) sensors, wearable non/minimally-invasive devices that measure glucose concentration by exploiting different physical principles, e.g., glucose-oxidase, fluorescence, or skin dielectric properties, and provide real-time measurements every 1–5 min. CGM opened new challenges in different disciplines, e.g., medicine, physics, electronics, chemistry, ergonomics, data/signal processing, and software development to mention but a few. This paper first makes an overview of wearable CGM sensor technologies, covering both commercial devices and research prototypes. Then, the role of CGM in the actual evolution of decision support systems for diabetes therapy is discussed. Finally, the paper presents new possible horizons for wearable CGM sensor applications and perspectives in terms of big data analytics for personalized and proactive medicine.
Wearable continuous glucose monitoring (CGM) sensors are revolutionizing the treatment of type 1 diabetes (T1D). These sensors provide in real-time, every 1–5 min, the current blood glucose concentration and its rate-of-change, two key pieces of information for improving the determination of exogenous insulin administration and the prediction of forthcoming adverse events, such as hypo-/hyper-glycemia. The current research in diabetes technology is putting considerable effort into developing decision support systems for patient use, which automatically analyze the patient’s data collected by CGM sensors and other portable devices, as well as providing personalized recommendations about therapy adjustments to patients. Due to the large amount of data collected by patients with T1D and their variety, artificial intelligence (AI) techniques are increasingly being adopted in these decision support systems. In this paper, we review the state-of-the-art methodologies using AI and CGM sensors for decision support in advanced T1D management, including techniques for personalized insulin bolus calculation, adaptive tuning of bolus calculator parameters and glucose prediction.
Minimally invasive continuous glucose monitoring (CGM) sensors are wearable medical devices that provide real-time measurement of subcutaneous glucose concentration. This can be of great help in the daily management of diabetes. Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a “raw” current signal via a glucose-oxidase electrochemical reaction. This electrical signal needs to be translated in real-time to glucose concentration through a calibration process. For such a scope, the first commercialized CGM sensors implemented simple linear regression techniques to fit reference glucose concentration measurements periodically collected by fingerprick. On the one hand, these simple linear techniques required several calibrations per day, with the consequent patient’s discomfort. On the other, only a limited accuracy was achieved. This stimulated researchers to propose, over the last decade, more sophisticated algorithms to calibrate CGM sensors, resorting to suitable signal processing, modelling, and machine-learning techniques. This review paper will first contextualize and describe the calibration problem and its implementation in the first generation of CGM sensors, and then present the most recently-proposed calibration algorithms, with a perspective on how these new techniques can influence future CGM products in terms of accuracy improvement and calibration reduction.