Giovanni Sparacino

Prof. Giovanni Sparacino

Department of Information Engineering, University of Padova, Padova, Italy
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Francesca ZanderigoFrancesca Zanderigo
Francesca Zanderigo
SCS. Corazza
S. Corazza
AMA. Maran
A. Maran
AFA. Facchinetti
A. Facchinetti
CCC. Cobelli
C. Cobelli
A clinically important task in diabetes management is the prevention of hypo/hyperglycemic events. In this proof-of-concept paper, we assess the feasibility of approaching the problem with continuous glucose monitoring (CGM) devices. In particular, we study the possibility to predict ahead in time glucose levels by exploiting their recent history monitored every 3 min by a minimally invasive CGM system, the Glucoday, in 28 type 1 diabetic volunteers for 48 h. Simple prediction strategies, based on the description of past glucose data by either a first-order polynomial or a first-order autoregressive (AR) model, both with time-varying parameters determined by weighted least squares, are considered. Results demonstrate that, even by using these simple methods, glucose can be predicted ahead in time, e.g., with a prediction horizon of 30 min crossing of the hypoglycemic threshold can be predicted 20-25 min ahead in time, a sufficient margin to mitigate the event by sugar ingestion.

5 September 2017 in Electronics
Verified
Journal Article
Open access
PDF file
Giacomo CapponGiacomo Cappon
Giacomo Cappon
GAGiada Acciaroli
Giada Acciaroli
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Worldwide, the number of people affected by diabetes is rapidly increasing due to aging populations and sedentary lifestyles, with the prospect of exceeding 500 million cases in 2030, resulting in one of the most challenging socio-health emergencies of the third millennium. Daily management of diabetes by patients relies on the capability of correctly measuring glucose concentration levels in the blood by using suitable sensors. In recent years, glucose monitoring has been revolutionized by the development of Continuous Glucose Monitoring (CGM) sensors, wearable non/minimally-invasive devices that measure glucose concentration by exploiting different physical principles, e.g., glucose-oxidase, fluorescence, or skin dielectric properties, and provide real-time measurements every 1–5 min. CGM opened new challenges in different disciplines, e.g., medicine, physics, electronics, chemistry, ergonomics, data/signal processing, and software development to mention but a few. This paper first makes an overview of wearable CGM sensor technologies, covering both commercial devices and research prototypes. Then, the role of CGM in the actual evolution of decision support systems for diabetes therapy is discussed. Finally, the paper presents new possible horizons for wearable CGM sensor applications and perspectives in terms of big data analytics for personalized and proactive medicine.

10 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Giacomo CapponGiacomo Cappon
Giacomo Cappon
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Wearable continuous glucose monitoring (CGM) sensors are revolutionizing the treatment of type 1 diabetes (T1D). These sensors provide in real-time, every 1–5 min, the current blood glucose concentration and its rate-of-change, two key pieces of information for improving the determination of exogenous insulin administration and the prediction of forthcoming adverse events, such as hypo-/hyper-glycemia. The current research in diabetes technology is putting considerable effort into developing decision support systems for patient use, which automatically analyze the patient’s data collected by CGM sensors and other portable devices, as well as providing personalized recommendations about therapy adjustments to patients. Due to the large amount of data collected by patients with T1D and their variety, artificial intelligence (AI) techniques are increasingly being adopted in these decision support systems. In this paper, we review the state-of-the-art methodologies using AI and CGM sensors for decision support in advanced T1D management, including techniques for personalized insulin bolus calculation, adaptive tuning of bolus calculator parameters and glucose prediction.

13 March 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
GAGiada Acciaroli
Giada Acciaroli
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
Minimally invasive continuous glucose monitoring (CGM) sensors are wearable medical devices that provide real-time measurement of subcutaneous glucose concentration. This can be of great help in the daily management of diabetes. Most of the commercially available CGM devices have a wire-based sensor, usually placed in the subcutaneous tissue, which measures a “raw” current signal via a glucose-oxidase electrochemical reaction. This electrical signal needs to be translated in real-time to glucose concentration through a calibration process. For such a scope, the first commercialized CGM sensors implemented simple linear regression techniques to fit reference glucose concentration measurements periodically collected by fingerprick. On the one hand, these simple linear techniques required several calibrations per day, with the consequent patient’s discomfort. On the other, only a limited accuracy was achieved. This stimulated researchers to propose, over the last decade, more sophisticated algorithms to calibrate CGM sensors, resorting to suitable signal processing, modelling, and machine-learning techniques. This review paper will first contextualize and describe the calibration problem and its implementation in the first generation of CGM sensors, and then present the most recently-proposed calibration algorithms, with a perspective on how these new techniques can influence future CGM products in terms of accuracy improvement and calibration reduction.

22 May 2018 in Journal of Diabetes Science and Technology
Verified
Journal Article
Closed access
MVMartina Vettoretti
Martina Vettoretti
Giacomo CapponGiacomo Cappon
Giacomo Cappon
GAGiada Acciaroli
Giada Acciaroli
AFAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
The recent announcement of the production of new low-cost continuous glucose monitoring (CGM) sensors, the approval of marketed CGM sensors for making treatment decisions, and new reimbursement criteria have the potential to revolutionize CGM use. After briefly summarizing current CGM applications, we discuss how, in our opinion, these changes are expected to extend CGM utilization beyond diabetes patients, for example, to subjects with prediabetes or even healthy individuals. We also elaborate on how the integration of CGM data with other relevant information, for example, health records and other medical device/wearable sensor data, will contribute to creating a digital data ecosystem that will improve our understanding of the etiology and complications of diabetes and will facilitate the development of data analytics for personalized diabetes management and prevention.

29 August 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Martina VettorettiMartina Vettoretti
Martina Vettoretti
Andrea FacchinettiAndrea Facchinetti
Andrea Facchinetti
Giovanni SparacinoGiovanni Sparacino
Giovanni Sparacino
CCClaudio Cobelli
Claudio Cobelli
$Objective:$ Type 1 diabetes (T1D) treatment requires exogenous insulin administrations finely tuned based on glucose monitoring to avoid hyper/hypoglycemia. The safety and effectiveness of insulin treatments is commonly assessed in clinical trials, which are time demanding and expensive. These limitations can be overtaken by in silico clinical trials (ISCT) that require realistic patient and treatment models. The aim is to develop a T1D patient decision simulator usable to perform reliable ISCT. $Methods:$ The T1D patient decision simulator was developed by connecting the UVA/Padova T1D model, which describes glucose, insulin and glucagon kinetics, with modules describing glucose monitoring devices, like self-monitoring of blood glucose (SMBG) and continuous glucose monitoring (CGM), the patient's behavior in making treatment decisions, and insulin administration. The reliability of the simulator was assessed by comparing its predictions with data collected in 44 T1D subjects using the Dexcom G5 Mobile CGM sensor as an adjunct to the Bayer Contour Next USB SMBG device. $Results:$ Metrics like time spent in eu/hypo/hyperglycemia of simulated data well match those observed in subjects. In particular, mean time in euglycemia, mean time in hyperglycemia and median time in hypoglycemia are 61.75% vs 63.60% (p-value=0.4825), 33.38% vs 33.40% (p-value=0.9950) and 3.17% vs 2.14% (p-value=0.1134), respectively, in real vs simulated data. $Conclusion:$ The proposed simulator can be used to perform credible ISCT in realistic insulin treatment scenarios. $Significance:$ The T1D patient decision simulator can be used to reliably assess novel insulin treatments, e.g. based on use of CGM only, in a realistic multiple-day scenario.