A practical direct-view scheme for generating arbitrary high-order cylindrical vector (HCV) beams by cascading vortex half-wave plates (VHPs) is presented. The combination of odd number 2n-1 VHPs for n≥1 can realize (m2n-1-m2n-2+…+m1)-order CV beams, in which m is the order number of VHP and the corresponding subscript 2n-1 represents the arrangement number of VHPs, and the cascading of even number 2n ones can obtain (m2n-m2n-1+…+m2-m1)-order CV beams. All 1-12 order CV beams, including the high-order anti-vortex CV (ACV) beams, are generated only by selectively cascading the VHPs with m=1, 3 and 8. The polarization properties of the generated HCV beams are investigated by measuring the corresponding Stokes parameters. It is experimentally demonstrated that arbitrary HCV beams are effectively achieved by the proposed method. The order numbers of CV beams can be greatly expanded by cascading limited types of VHPs.
A convenient and versatile scheme to generate continuously adjustable cylindrical vector (CV) and vortex beams by multiplexing and cascading passive vortex half-wave plates (VHPs) is proposed. (−24)–24 order CV or vortex beams are generated only based on VHPs with m = 1, 3, and 8. The coaxial and small-angle interference are introduced to detect orders. For coaxial interference of -order and -order vortex beams, the intensity distribution is spirally fan shaped. The partition number is N = |− |, and the spiral direction can distinguish the sign of topological charge with higher value. Fork-shaped fringes appear in the center for small-angle interference between vortex beams with incident angle and . The forking number between two fringes meets N = |− |, and the forks face upward when (− )(− ) < 0, and face downward when (− )(− ) > 0. Particularly, when one of the beams is a Gaussian beam, such as = 0, the value and sign of the topological charge can be directly detected. And for the interference between CV and Gaussian plane beams, the partition number N is positively correlated with the polarization order P, with N=|P| or N =2|P| for coaxial or small-angle interference, respectively, and corresponding sign can be identified by the polarization azimuth distributions measured by Stokes parameters. It is experimentally demonstrated that the proposed scheme can effectively generate continuously adjustable CV and vortex beams by programming limited VHPs, greatly expanding order numbers with low cost, low energy consumption, and high utilization, and the coaxial and small-angle interference method can conveniently detect the corresponding orders without borrowing redundant devices.
A hypervapotron (HV) loop test facility was built to conduct some experiments of heat transfer. Phenomena of HV were observed using the techniques of planar laser-induced fluorescence, high-speed photography, and particle image velocimetry. According to the design of the ITER cooling water system, the fluid flow and condition parameters were utilized: 1) CuCrZr alloy material; 2) triangular and rectangular fin structures; 3) inlet subcooling temperature of 298 K; and 4) rhodamine B solution flow velocity of 0.3-0.5 m/s. It was found that the heat transfer coefficient of the rectangular fin was 1.3-1.5 times higher than that of the triangular fin under the same test conditions. Furthermore, the preliminary mechanism of the heat transfer was explained by the coupling effect of the vortex flow with vapor bubble in the fin pitch, and the heat transfer efficiency was extraordinarily dependent on maintaining the time of vortex formation between the fins.
1 July 2024 in Journal of Thermophysics and Heat Transfer
In this study, numerical simulations are conducted to investigate the effects of initial models (parallel and symmetrical arrangement) using interruption fins on the flow and heat transfer characteristics of microchannel heat sink (MHS). The results indicate that MHS with symmetrical fin arrangement has a higher Nusselt number and lower thermal resistance. The vortices perpendicular to the flowpath is the main factor of affecting the heat transfer characteristics. Because of the higher vorticity, the channel with symmetrical fins achieves higher heat transfer performance. To further improve the heat transfer performance, three modified models (models III–V) are obtained by adopting the methods of staggered, reducing fin quantity, and adding pin fins, respectively. The staggered arrangement of fins can deepen the secondary flow in the channel, and the additional vortices are formed with adding pin fins, which can enhance heat transfer capacity in models III and V. On the other hand, reducing the number of fins can damage some vortices, which can actually reduce heat transfer performance. It is worth noting that both the staggered fins and the pin fins significantly increase the pressure drops of the channel, while reducing the fins number leads to an obvious decrease in the pressure drop.