This research investigates the suitability of printed polyamide 12 (PA12) and its dyed version to support cells in bioengineering applications. For this purpose, human gingival fibroblasts (hGF06) were cultured on PA-12 scaffolds that were 3D-printed by Multi Jet Fusion (MJF). The study examined the direct cultivation of cells on MJF-printed cell culture scaffolds and the effect of leachate of PA-12 printed by MJF on the cultured cells. The article presents research on the surface treatment of PA12 material used in 3D printing and the effect of automatic staining on cell vitality and proliferation in vitro. The study presents a unique device designed exclusively for staining prints made of the biocompatible material PA12 and demonstrates the compatibility of 3D-printed polyamide 12 parts stained in the novel device with a nutrient culture medium and cells. This novel PA12 surface treatment for biomedical purposes does not affect the compatibility with the culture medium, which is essential for cell viability and proliferation. Fluorescence microscopy revealed that mitochondrial fitness and cell survival were not affected by prolonged incubation with clear or dyed PA12 3D-printed parts.
Purpose: The study’s starting point is to find a low-cost and best-fit solution for comfortable movement for a recreational runner with knee pain using an orthopedic device. It is a case study. The research aims to apply digitization, CAD/CAM tools, and 3D printing to create an individual 3D running insole. The objective is to incorporate flexible shape optimization would provide comfort reductions in foot plantar pressures in one subject with knee pain while running. The test hypothesis was if it is possible to make it from one material. For this purpose, we created a new digital workflow based on the Decision Tree method and analyzed pain and comfort scores during user testing of prototypes. Patient and Methods: The input data were obtained during a professional examination by a specialist doctor in the orthopedic outpatient clinic in the motion laboratory (DIERS 4D Motion Lab, Germany) with the output of data on the proband’s complex movement stereotype. Surface and volumetric data were obtained in the biomedical laboratory with the 3D scanner. We modified the digital 3D foot models in 3D mesh software, developed the design in SW Gensole (Gyrobot, UK), and finally incorporated the internal structure and the surface layer of the insole data of the knowledge from the medical examination, comfort analyses, and scientific studies findings. Results: Four complete 3D-printed prototypes (n=4) with differences in density and correction elements were designed. All of them were fabricated on a 3D printer (Prusa i3 MK3S, Czech Republic) with flexible TPU material suitable for skin contact. The Participant tested each of them five times in the field during a workout and final insoles three months on the routine training. Conclusion: A novel workflow was created for designing, producing, and testing full 3D-printed insoles. The product is fit for immediate use.
The increasing demand for dental aesthetics, articulation corrections, and solutions for pain and frequent bruxism demands quick and effective restorative dental management. The biomedical research aimed to create a beneficial, ecological, and readily available anterior deprogrammer to determine the centric relation (CR) of cases. This medical device is additively manufactured from a biocompatible material. Size is customizable based on the width of the patient’s anterior central incisors. This is a pilot study with two subjects. The task was to develop a complete data protocol for the production process, computer-aided design (CAD), and three-dimensional (3D) printing of the anterior deprogrammers. The research focused on creating simple and practically applicable tools for the dentist’s prescription (anterior deprogrammer in three sizes), and secondly for the communication between the dentist and the patient (computer application). The tested hypothesis was whether, according to these novel tools, it is possible to produce functional occlusal splints, which could be manufactured using current technologies. This study compared a traditional splint with a digitally designed and 3D-printed one. The tested hypothesis was whether manufactured occlusal splints differ in patients’ subjective perception of comfort. Each conservative treatment was monitored for ten weeks. Initial results are promising; no statistically significant difference was found between the productive technologies.
30 June 2020 in Lékař a technika - Clinician and Technology
The aim of this study is to assess the effect of footwear on postural status of a group of volunteers representing the general population of female students. Based on the assumption that the elegant shoe with tapered toe and high heel does not provide adequate foot support, the study was designed to assess its direct link and impact to body segment alignment and resulting negative effect on posture. Repetition of this misalignment ensures the individual circumstances of posture. Due to the heel elevation, the weight is transferred to the distal part, resulting in a postural response of the entire musculoskeletal system to maintain balance. The group consisted of 30 women of the age 18–28 years with an average age of 22.7 years, height 167±0.3 cm and weight 57±0.9 kg. Anamnesis and aspection were performed to assess of the occurrence of shortened and weakened muscles and subsequently the patient's standing was examined. Two static methods were chosen for evaluation of the posture. The first one was the Silhouette Posture Analysis and the evaluation method by Jaros and Lomnicka. The result was the identification of typical muscle imbalance as the most common presumption of faulty posture, and it was confirmed that footwear affects a person's natural posture. Differences in the sensitivity of the two methods were also identified and studies are not only appropriate that but also evaluate differences in impact among subjects.
In this study, the authors focus on optimizing the processing parameters for the fabrication of biodegradable polymer filaments intended for subsequent 3D printing of biomedical structures and implants. Following extrusion and additive manufacturing, the produced materials underwent a comprehensive evaluation that included mechanical, microbiological, biofilm formation, and electron microscopy analyses. The complexity of these tests aimed to determine the potential of the developed materials for biomedical applications, particularly in the field of scaffold fabrication. At the initial stage, three types of filaments (technical designations 111, 145, and 146) were produced using Fused Filament Fabrication (FFF) technology. These filaments were based on a PLA/PHB matrix with varying types and concentrations of plasticizers. Standardized destructive tensile and compressive mechanical tests were conducted using an MTS Insight 1 kN testing system equipped with an Instron 2620-601 extensometer. Among the tested samples, the filament labeled 111, composed of PLA/PHB thermoplastic starch and a plasticizer, exhibited the most favorable mechanical performance, with a Young’s modulus of elasticity of 4.63 MPa for 100% infill. The filament labeled 146 had a Young’s modulus of elasticity of 4.53 MPa for 100% infill and the material labeled 145 had a Young’s modulus of elasticity of 1.45 MPa for 100% infill. Microbiological assessments were performed to evaluate the capacity of bacteria and fungi to colonize the material surfaces. During bacterial activity assessment, we observed biofilm formation on the examined sample surfaces of each material from the smooth and rough sides. The colony-forming units (CFUs) increased directly with the exposure time. For all samples from each material, the Log10 (CFU) value reached above 9.41 during 72 h of incubation for the activity of each type of bacteria (Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans). Scanning electron microscopy provided insight into the surface quality of the material and revealed its local quality and purity. Surface defects were eliminated by this method. Overall, the results indicate that the designed biodegradable filaments, especially formulation 111, have promising properties for the development of scaffolds intended for hard tissue replacement and could also be suitable for regenerative applications in the future after achieving the desired biological properties.
Photobiomodulation (PBM) has gained increasing attention in tissue engineering and cell biology, yet reproducible in vitro studies remain limited by the availability of standardized irradiation platforms. This study presents the design, construction, and technical validation of Ce3Light, a modular LED-based irradiation system developed for controlled photobiomodulation experiments under standard cell culture conditions. The platform was fabricated using additive manufacturing (PA12) and incorporates interchangeable LED modules, integrated monitoring of illuminance and temperature, and compatibility with conventional CO2 incubators. To demonstrate its applicability for in vitro research, the system was evaluated using MRC-5 fibroblasts exposed to four wavelengths (460, 530, 660, and 800 nm). Cellular responses were assessed by measuring intracellular glutathione levels and dehydrogenase activity. The experiments confirmed that the platform enabled stable and reproducible irradiation while detecting wavelength-dependent cellular responses consistent with previous reports in the literature. These findings primarily validate the functionality and suitability of Ce3Light as an experimental platform rather than establish new biological mechanisms. The developed system provides a versatile, reproducible, and adaptable tool for future photobiomodulation studies requiring precise control of irradiation conditions.