This work is devoted to the research of porous titanium alloy structures suitable for use in biomedical applications. Mechanical properties were examined on six series of samples with different structures and porosity via static compressive test to identify the type of structure suitable for elimination of the “stress shielding” effect. In addition, high porosity is desirable due to the overgrowth of bone tissue into the internal structure of the implant. The samples were made of titanium alloy Ti6Al4V by using selective laser melting (SLM) additive manufacturing. The series of samples differ from each other in pore size (200, 400, and 600 µm) and porous structure topology (cubic or trabecular). The actual weight of all samples, which plays an important role in identifying other characteristics, was determined. Compressive tests were focused on the detection of maximum stress. The highest porosity and thus the lowest weight were achieved in the samples with a trabecular structure and 600 µm pore size. All tested samples reached optimal values of maximum stress and tensile strength. The most appropriate mechanical properties were observed for samples with a 200 µm pore diameter and cubic structure.
One trend in tissue engineering and regenerative medicine is the development of degradable composite polymers. The aim of this study was the comprehensive analysis of Polylactic acid (PLA)/Polyhydroxybutyrate (PHB) + Hydroxyapatite (HA)/Tricalcium phosphate (TCP) material from filament production to mechanical testing of samples with different infills and the production of an implant replacement for an intervertebral disc. Filament Maker—Composer 450 (3devo; Netherlands) was used to produce filaments. Experimental samples and the implant for the intervertebral disc were made using FDM technology using a DeltiQ2 3D printer (Trilab, Czech Republic). Mechanical testing of experimental samples was performed on an Inspekt TABLE 5 kN (Hegewald & Peschke, Nossen, Germany). Microscopic analysis, cytotoxicity test, and filament diameter analysis using descriptive statistics were also part of the focus. The results of the analysis of the diameter of the filament show that the filament meets the prescribed standard. The cytotoxicity test for PLA/PHB + HA/TCP material showed no toxicity. Microscopic analysis showed an even distribution of the ceramic component in the composite polymer. Mechanical testing showed a reduction in mechanical properties with 75% and 50% of the filling of experimental samples. All experimental samples subjected to mechanical testing showed higher tensile and compressive strength values compared to the values of the mechanical properties of vertebral trabecular bones, as reported in the literature. It can therefore be concluded that the material under investigation, PLA/PHB + HA/TCP appears to be a suitable candidate for hard tissue replacement.
The present study deals with preparing a polymer-based material with incorporated ceramics and monitoring changes in properties after in vitro natural degradation. The developed material is a mixture of polymers of polylactic acid and polyhydroxybutyrate in a ratio of 85:15. Ceramic was incorporated into the prepared material, namely 10% hydroxyapatite and 10% tricalcium phosphate of the total volume. The material was processed into a filament form, and types of solid and porous samples were prepared using additive technology. These samples were immersed in three different solutions: physiological solution, phosphate-buffered saline, and Hanks’ solution. Under constant laboratory conditions, changes in solution pH, material absorption, weight loss, changes in mechanical properties, and surface morphology were monitored for 170 days. The average value of the absorption of the solid sample was 7.07%, and the absorption of the porous samples was recorded at 8.33%, which means a difference of 1.26%. The least change in pH from the reference value of 7.4 was noted with the phosphate-buffered saline solution. Computed tomography was used to determine the cross-section of the samples. The obtained data were used to calculate the mechanical properties of materials after degradation. The elasticity modulus for both the full and porous samples degraded in Hanks’ solution (524.53 ± 13.4 MPa) has the smallest deviation from the non-degraded reference sample (536.21 ± 22.69 MPa).
The paper deals with the separation of the third cervical vertebra using the software VGStudio MAX, Mimics, and inVesalius. During the separation, various parameters of the threshold were used to determine the effect. The comparison of models from Mimics and inVesalius to VGStudio MAX showed that the cumulative variance distribution for 95% surface coverage is less than 0.935 mm. When comparing medically oriented software, Mimics and inVesalius, the deviation was less than 0.356 mm. The model was made of polylactic acid (PLA) material on a low-cost 3D printer, Prusa i3 MK2.5 MMU1. The printed model was scanned by four scanners: Artec Eva, 3Shape D700, Steinbichler Comet L3D, and Creaform EXAscan. The outputs from the scanners were compared to the reference model (standard tessellation language (STL) model for 3D printing) as well as to the scanner with the best accuracy (3Shape). Compared to the publications below, the analysis of deviations was evaluated on the entire surface of the model and not on selected dimensions. The cumulative variance distribution for comparing the output from the 3D scanner with the reference model, as well as comparing the scanners, shows that the deviation for 95% of the surface coverage is at the level of 0.300 mm. Since the model of the vertebra is planned for education and training, the used software and technologies are suitable for use in the design and the production process.