The paper deals with the evaluation of mechanical properties of 3D-printed samples based on high-strength steel powder system maraging steel using direct metal laser sintering (DMLS), which is currently being put into technical practice. The novelty of this article is that it analyzes mechanical properties of samples both printed and age hardened as well as examining the fracture surfaces. When comparing the manufacturer’s range with our recorded values, samples from Set 1 demonstrated strength ranging from 1110 to ultimate 1140 MPa. Samples from Set 2 showed tensile strength values that were just below average. Our recorded range was from 1920 to ultimate 2000 MPa while the manufacturer reported a range from 1950 to 2150 MPa. The tensile strength was in the range from 841 to ultimate 852 MPa in Set 1, and from 1110 to ultimate 1130 MPa in Set 2.
The advancing development in biomaterials and biology has enabled the extension of 3D printing technology to the bioadditive manufacturing of degradable hard tissue substitutes. One of the key advantages of bioadditive manufacturing is that it has much smaller design limitations than conventional manufacturing and is therefore capable of producing implants with complex geometries. In this study, three distinct blends of polylactic acid (PLA) and polyhydroxybutyrate (PHB) were produced using Fused Deposition Modeling (FDM) technology. Two of these blends were plasticized with oligomeric lactic acid (OLA) at concentrations of 5 wt% and 10 wt%, while the third blend remained unplasticized. Each blend was fabricated in two structural modifications: solid and porous. The biodegradation behavior of the produced specimens was examined through an in vitro experiment using three different immersion solutions: saline solution, Hank’s balanced salt solution (HBSS), and phosphate-buffered saline (PBS). All examined samples were also subjected to chemical analysis: atomic absorption spectroscopy (AAS), scanning electron microscopy (SEM), and energy-dispersive spectrometry (EDS). The results of the degradation experiments indicated a predominantly better absorption capacity of the samples with a porous structure compared to the full structure. At the same time, the blend containing a higher concentration of OLA exhibited enhanced pH stability over the evaluation period, maintaining relatively constant pH values before experiencing a minor decline at the end of the study. This observation indicates that the increased presence of the plasticizer may provide a buffering effect, effectively mitigating the acidification associated with material degradation.
Biodegradable magnesium implants offer a solution for bone repair without the need for implant removal. However, concerns persist regarding peri-implant gas accumulation, which has limited their widespread clinical acceptance. Consequently, there is a need to minimise the mass of magnesium to reduce the total volume of gas generated around the implants. Incorporating porosity is a direct approach to reducing the mass of the implants, but it also decreases the strength and degradation resistance. This study demonstrates that the infiltration of a calcium phosphate cement into an additively manufactured WE43 Mg alloy scaffold with 75 % porosity, followed by hydrothermal treatment, yields biodegradable magnesium/hydroxyapatite interpenetrating phase composites that generate an order of magnitude less hydrogen gas during degradation than WE43 scaffolds. The enhanced degradation resistance results from magnesium passivation, allowing osteoblast proliferation in indirect contact with composites. Additionally, the composites exhibit a compressive strength 1.8 times greater than that of the scaffolds, falling within the upper range of the compressive strength of cancellous bone. These results emphasise the potential of the new biodegradable interpenetrating phase composites for the fabrication of temporary osteosynthesis devices. Optimizing cement hardening and magnesium passivation during hydrothermal processing is crucial for achieving both high compressive strength and low degradation rate.
The increasing demand for dental aesthetics, articulation corrections, and solutions for pain and frequent bruxism demands quick and effective restorative dental management. The biomedical research aimed to create a beneficial, ecological, and readily available anterior deprogrammer to determine the centric relation (CR) of cases. This medical device is additively manufactured from a biocompatible material. Size is customizable based on the width of the patient’s anterior central incisors. This is a pilot study with two subjects. The task was to develop a complete data protocol for the production process, computer-aided design (CAD), and three-dimensional (3D) printing of the anterior deprogrammers. The research focused on creating simple and practically applicable tools for the dentist’s prescription (anterior deprogrammer in three sizes), and secondly for the communication between the dentist and the patient (computer application). The tested hypothesis was whether, according to these novel tools, it is possible to produce functional occlusal splints, which could be manufactured using current technologies. This study compared a traditional splint with a digitally designed and 3D-printed one. The tested hypothesis was whether manufactured occlusal splints differ in patients’ subjective perception of comfort. Each conservative treatment was monitored for ten weeks. Initial results are promising; no statistically significant difference was found between the productive technologies.
In this study, the authors focus on optimizing the processing parameters for the fabrication of biodegradable polymer filaments intended for subsequent 3D printing of biomedical structures and implants. Following extrusion and additive manufacturing, the produced materials underwent a comprehensive evaluation that included mechanical, microbiological, biofilm formation, and electron microscopy analyses. The complexity of these tests aimed to determine the potential of the developed materials for biomedical applications, particularly in the field of scaffold fabrication. At the initial stage, three types of filaments (technical designations 111, 145, and 146) were produced using Fused Filament Fabrication (FFF) technology. These filaments were based on a PLA/PHB matrix with varying types and concentrations of plasticizers. Standardized destructive tensile and compressive mechanical tests were conducted using an MTS Insight 1 kN testing system equipped with an Instron 2620-601 extensometer. Among the tested samples, the filament labeled 111, composed of PLA/PHB thermoplastic starch and a plasticizer, exhibited the most favorable mechanical performance, with a Young’s modulus of elasticity of 4.63 MPa for 100% infill. The filament labeled 146 had a Young’s modulus of elasticity of 4.53 MPa for 100% infill and the material labeled 145 had a Young’s modulus of elasticity of 1.45 MPa for 100% infill. Microbiological assessments were performed to evaluate the capacity of bacteria and fungi to colonize the material surfaces. During bacterial activity assessment, we observed biofilm formation on the examined sample surfaces of each material from the smooth and rough sides. The colony-forming units (CFUs) increased directly with the exposure time. For all samples from each material, the Log10 (CFU) value reached above 9.41 during 72 h of incubation for the activity of each type of bacteria (Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans). Scanning electron microscopy provided insight into the surface quality of the material and revealed its local quality and purity. Surface defects were eliminated by this method. Overall, the results indicate that the designed biodegradable filaments, especially formulation 111, have promising properties for the development of scaffolds intended for hard tissue replacement and could also be suitable for regenerative applications in the future after achieving the desired biological properties.
29 January 2026 in IPSI Transactions on Internet Research
This paper has been replaced by https://doi.org/10.58245/ipsi.tir.2602.02Corr due to a high level of similarity with the Master’s thesis authored by the article’s first author, Jakub L'ach. The article was subsequently revised, reducing the similarity index to below 9%. This paper investigates the prediction of finger motion intention using surface electromyography (sEMG) signals and supervised machine learning models. sEMG sensors provide a noninvasive means of capturing muscle activity, enabling applications in prosthetics, rehabilitation, and human-computer interface. The study explores signal preprocessing techniques, time-frequency domain transformations, and machine learning algorithms, including SVM, Random Forest, and XGBoost. The results highlight the challenges posed by noise and variability in sEMG signals, and suggest strategies for improving prediction accuracy and real-world applicability.