Anaerobic co-digestion allows for under-utilised digesters to increase biomethane production. The organic fraction of municipal solid waste (OFMSW), i.e., food waste, is an abundant substrate with high degradability and gas potential. This paper investigates the co-digestion of mixed sludge from wastewater treatment plants and OFMSW, through batch and continuous lab-scale experiments, modelling, and microbial population analysis. The results show a rapid adaptation of the process, and an increase of the biomethane production by 20% to 40%, when co-digesting mixed sludge with OFMSW at a ratio of 1:1, based on the volatile solids (VS) content. The introduction of OFMSW also has an impact on the microbial community. With 50% co-substrate and constant loading conditions (1 kg VS/m3/d) the methanogenic activity increases and adapts towards acetate degradation, while the community in the reference reactor, without a co-substrate, remains unaffected. An elevated load (2 kg VS/m3/d) increases the methanogenic activity in both reactors, but the composition of the methanogenic population remains constant for the reference reactor. The modelling shows that ammonium inhibition increases at elevated organic loads, and that intermittent feeding causes fluctuations in the digester performance, due to varying inhibition. The paper demonstrates how modelling can be used for designing feed strategies and experimental set-ups for anaerobic co-digestion.
Membrane hybrid processes—coagulation coupled with ultrafiltration (UF)—have become a common method to comply with the legal, chemical, and microbiological requirements for drinking water. The main advantages of integrating coagulation with membrane filtration are the enhanced removal of natural organic matter (NOM) and reduced membrane fouling. With in-line coagulation, coagulants are patched into the feed stream directly prior to the membrane process, without removing the coagulated solids. Compared with conventional coagulation/sedimentation, in-line coagulation/membrane reduces the treatment time and footprint. Coagulant dosing could be challenging in raw water of varying quality; however, with relatively stable specific ultraviolet absorbance (SUVA), dosing can be controlled. Recent studies indicate that UV absorbance correlates well with humic substances (HS), the major fraction to be removed during coagulation. This paper describes and evaluates a 30-month UF pilot trial on the surface water of Lake Neden (Sweden), providing drinking water to 60,000 residents. In this study, automatic coagulant dosing based on online measurement was successfully applied. Online sensor data were used to identify the current optimal aluminium coagulation conditions (0.5–0.7 mg L−1) and the potential boundaries (0.9–1.2 mg L−1) for efficient future (2040) NOM removal. The potential increase in NOM could affect the Al dose and drinking water quality significantly within 20 years, should the current trends in dissolved organic carbon (DOC) prevail. UV absorbance, the freshness index, and liquid chromatography-organic carbon detection (LC-OCD) measurements were used to optimise the process. Careful cross-calibration of raw and filtered samples is recommended when using online sensor data for process optimisation, even in low-turbidity water (formazin nephelometric unit (FNU) < 5).
Microbial monitoring of drinking water is required to guarantee high quality water and to mitigate health hazards. Flow cytometry (FCM) is a fast and robust method that determines bacterial concentrations in liquids. In this study, FCM was applied to monitor the dynamics of the bacterial communities over one year in a full-scale drinking water distribution system (DWDS), following implementation of ultrafiltration (UF) combined with coagulation at the drinking water treatment plant (DWTP). Correlations between the environmental conditions in the DWDS and microbial regrowth were observed, including increases in total cell counts with increasing retention time (correlation coefficient R = 0.89) and increasing water temperature (up to 5.24-fold increase in cell counts during summer). Temporal and spatial biofilm dynamics affecting the water within the DWDS were also observed, such as changes in the percentage of high nucleic acid bacteria with increasing retention time (correlation coefficient R = −0.79). FCM baselines were defined for specific areas in the DWDS to support future management strategies in this DWDS, including a gradual reduction of chloramine.
Over the years, various technologies have been utilized for Natural Organic Matter (NOM) removal with varying degrees of success. Conventional treatment methods comprising of coagulation, flocculation, sedimentation, or filtration are widely used to remove NOM. An alternative to these conventional methods is to use spiral wound membranes. These membranes tend to remove too much hardness whilst being ineffective in disinfection. They also have a low tolerance to chlorine and thus, have limited chemical cleaning options. In this study, we investigated how an alternative and new innovative filtration concept, based on capillary NF membranes from modified polyethersulfone (PES), may be used to treat soft but humus-rich surface waters. Comprehensive performance tests, with a fully automated membrane pilot equipped with a full-scale sized test module (40 m2 membrane surface), were conducted at WTP Görvälnverket, which is operated by the water utility Norrvatten, providing drinking water from Mälaren (SUVA = 2.7–3.3, TOC = 7.0–10.0 mg·L−1) for about 500,000 people in the northern part of the Swedish capital of Stockholm. The removal of both UV and DOC was modeled using a solution diffusion approach. The optimized parameters allow deducing optimal operation conditions with respect to energy, water consumption, and permeate water quality. Optimal cross flow velocity was determined to be 0.75 m·s−1 at 80% recovery and a flux of 12–18 L·m−2·h−1. Under these conditions, 80% of the UV, 75% of the Humic Substances (MW = 600) and 70% of TOC were removed (from 8 to below 2 mg·L−1). A higher cross flow velocity led to marginal improvement (+2%) while both higher and lower membrane fluxes degraded permeate water quality. Apparent optimized diffusion coefficients for UV and TOC were around 1.2–2.4 × 10−10·m2·s−1 and were similar to values found in the literature. Due to their higher diffusion coefficients and higher permeability coefficient, only 40% of the low molecular weight acids (MW = 300–400) were retained. Approximately 30%–40% of the low molecular weight acids in the permeate can be further removed using GAC post NF. The resulting energy consumption of a hypothetical four-stage design, at average operating temperature of 5.73 °C, was calculated to be around 0.6 kWh·m−3 produced water.
A full-scale inside out hollow fibre membrane module was operated in a pilot-scale water treatment plant in Sweden for a period of 12 months from August 2013 to July 2014. Liquid chromatography– organic carbon detection (LC-OCD) chromatogram indicated the membranes could effectively remove 86% of dissolved organic carbon and 92% of humic substances from the feedwater. Routine cleaning-in-place was conducted to remove any fouling material accumulated on the membranes. Autopsy of the aged membrane samples after 12 months’ operation suggested no significant changes were detected for the membrane samples obtained from the top, middle and bottom sections of the membrane module and were similar to the virgin membrane sample.
Reliable and safe drinking water supply requires adequate risk management. Decision support models can aid decisionmakers to effectively evaluate risk mitigation measures and allocate societal resources. Here, a Swedish case study illustrates how the installation of ultrafiltration membranes can be evaluated by combining risk assessment and cost-benefit analysis. Quantitative microbial risk assessment was used to assess several contamination sources and estimate the achieved risk reduction from waterborne pathogens using Campylobacter, Norovirus, and Cryptosporidium as reference pathogens. The societal value of the improved water quality was estimated in the cost-benefit analysis by monetising the gained quality adjusted life years and aesthetic water quality improvements. The calculated net present value (mean of 7 MEUR) indicated that the installation of the ultrafiltration membranes was a sound investment from a societal economic perspective. The ultrafiltration membranes reduced the annual probability of infection from 3 × 10−2 to 10−7, well below the U.S. EPA’s acceptable level, as well as improving the aesthetic quality of the drinking water. The results provide a novel example of the importance for water distributors to consider not only health-related metrics when evaluating treatment options or monitoring the drinking water quality, but to also consider the aesthetic quality of the drinking water.