Shengwei Fang

Ms. Shengwei Fang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Energies
Verified
Journal Article
Open access
PDF file
Li ZhangLi Zhang
Li Zhang
SFShengwei Fang
Shengwei Fang
GWGuozheng Wang
Guozheng Wang
TZTong Zhao
Tong Zhao
Liang ZouLiang Zou
Liang Zou
In recent years, with the rapid development of offshore wind turbines (WTs), the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs, the influencing factors and the response rules of transient overvoltage are analyzed. In this paper, a new integrated electromagnetic transient model of offshore WTs is established by using the numerical calculation method of the electromagnetic field first. Then, based on the lightning model and considering the impedance of the lightning channel, the transient overvoltage of lightning is analyzed. Last, the electromagnetic transient model of offshore WTs is simulated and analyzed by using the alternative transients program electro-magnetic transient program (ATP-EMTP) software. The influence factors of lightning transient overvoltage are studied. The main influencing factors include the sea depth, the blade length, the tower height, the lightning flow parameters, the lightning strike point, and the blade rotation position. The simulation results show that the influencing factors mentioned above have different effects on the lightning transient overvoltage. The results of the study have some guiding significance for the design of the lightning protection of the engine room.

12 December 2018 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
YWYali Wang
Yali Wang
LZLiang Zou
Liang Zou
YCYongshuai Chen
Yongshuai Chen
SFShengwei Fang
Shengwei Fang
In view of the overvoltage problem of an ultra‐high‐voltage DC (UHVDC) AC/DC hybrid system, this study analyses the overvoltage condition under various fault types and gives the identification criterion of the overvoltage form. Firstly, the model of the ± 800 kV UHVDC and 1000 kV UHV AC hybrid system was established in Simulink. The relevant parameters of current and voltage in the hybrid system were simulated and analysed to verify the accuracy and effectiveness of the model. Secondly, the fault simulation of the two system models of AC and DC, respectively, is carried out, and the theoretical analysis of the internal overvoltage caused by the fault is made. Finally, the simulation of the overvoltage condition of the hybrid system under two conditions is carried out, and the waveforms of the important parameters of the AC system and the DC system are obtained. The waveform of each parameter is analysed and the conclusion is obtained. The type of the overvoltage fault of the UHV AC/DC hybrid system is analysed, which provides the basis for fault type judgement.