Christopher Tsang

Dr. Christopher Tsang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Journal of Architectural Engineering
Verified
Journal Article
Closed access
PDF file
CTChristopher Tsang
Christopher Tsang
ESEftychia Spentzou
Eftychia Spentzou
KLKevin J. Lomas
Kevin J. Lomas
MHMiaomiao He
Miaomiao He
China’s Hot Summer and Cold Winter zone, with a 550 million population, accounts for 45% of China’s building energy consumption; as such, building retrofits could offer substantial energy savings. This paper presents results from a dynamic thermal modeling study of a typical urban multistory residential building under three types of air conditioning (A/C) operating schedules. Seven energy-saving retrofit measures (external wall insulation, roof insulation, double-glazing, air infiltration control, window shading, communal staircase design, and energy-efficient A/C) were evaluated, and the retrofit strategy with the highest annual energy savings and lowest thermal discomfort was identified. This retrofit strategy was subsequently evaluated for other flats (apartments) with different orientations and positions in the typical building. The annual space-conditioning energy could be reduced by 59%–68%, depending on the flat location, orientation and A/C operating schedule. The findings were then scaled up to estimate the potential energy savings in the city of Chongqing. More than 320 multistory residential buildings were represented by 12 archetypes. Space-conditioning energy consumption was reduced by up to 58% (18.8 TWh). This work provides evidence of the potential energy savings of city-scale retrofit that could aid China in reducing building energy consumption and achieving net-zero carbon emissions by 2050. It was possible to explore a wide range of refurbishment options for China’s highly energy-consuming Hot Summer and Cold Winter zone with hot, humid summers and mild, chilly winters using dynamic thermal models. The simulation models developed in this paper revealed that double-glazing with air infiltration control is the most effective retrofit measure for middle-floor flats, but for top-floor flats, roof insulation is the most effective; south-facing flats consume more high energy consumption than north-facing flats. Furthermore, high-rise buildings consume less energy than low-rise buildings per square meter, and one-bedroom flats consume more energy than three-bedroom flats per square meter. This study also demonstrated the procedure to develop thermal comfort evaluation methods, A/C operating schedules, and construction parameters from literature in this climate zone when there were no standards or databases available. Findings offer a tangible, clear retrofit strategy that considers different A/C operating schedules, flat locations, and building archetypes. It can assist decision-making by practitioners and homeowners aiming to upgrade the building stock of this climate zone which covers 3.4 billion m2 with a 550 million population to reduce energy consumption and improve occupant comfort.

5 June 2025 in Energies
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
Ljubomir JankovicLjubomir Jankovic
Ljubomir Jankovic
William SwanWilliam Swan
William Swan
Richard FittonRichard Fitton
Richard Fitton
GHGrant Patrick Henshaw
Grant Patrick Henshaw
This study investigates the relative benefits of solar thermal (ST) and photovoltaic (PV) systems integrated with air-source heat pumps for domestic hot water production in newly built residential buildings. Using calibrated DesignBuilder simulations of “The Future Home” located in Energy House 2.0, an environmental chamber, the study analyzes energy performance and carbon emissions for eight scenarios: (1) baseline heat pump only, (2) heat pump with 4 m2 PV panels, (3) heat pump with 4 m2 ST panels, (4) heat pump with 2 m2 PV + 2 m2 ST panels, and (5–8) variants with increased hot water demand. While ST systems directly heat water through thermal energy transfer, PV systems contribute to water heating indirectly by providing electricity to power the heat pump. The results show that the ST system provides 964.6 kWh of thermal energy annually, increasing to 1528 kWh with enhanced hot water demand, while a similarly sized PV system generates 532.5 kWh of electricity. The research reveals that Standard Assessment Procedure methodology’s fixed hot water demand assumptions could significantly underpredict solar thermal benefits, potentially discouraging UK house builders from adopting this technology.

20 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
JPJim Parker
Jim Parker
DGDavid Glew
David Glew
A substantial number of dwellings in the UK have poor building fabric, leading to higher carbon emissions, fuel expenses, and the risk of cold homes. To tackle these challenges, domestic energy efficiency policies are being implemented. One effective approach is the use of energy models, which enable sensitivity analysis to provide valuable insights for policymakers. This study employed dynamic thermal simulation models for 32 housing archetypes representative of solid-walled homes in the UK to calculate the heat loss and the sensitivity coefficient per building fabric feature, after which a metric Heat Loss Sensitivity (HLS) index was established to guide the selection of retrofit features for each archetype. The building fabric features’ inputs were then adjusted to establish both lower and upper bounds, simulating low and high performance levels, to predict the how space heating energy demand varies. The analysis was extended by replicating the process with various scenarios considering climates, window-to-wall ratios, and overshadowing. The findings highlight the external wall as the primary consideration in retrofitting due to its high HLS index, even at high window-to-wall ratios. It was also established that dwelling type is important in retrofit decision-making, with floor and loft retrofits having a high HLS index in bungalows. Furthermore, the analysis underlines the necessity for Standard Assessment Procedure assessors to evaluate loft U-value and air permeability rates prior to implementing retrofit measures, given the significance of these factors in the lower and upper bounds analysis. Researchers globally can replicate the HLS index approach, facilitating the implementation of housing retrofit policies worldwide.

22 July 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
Richard FittonRichard Fitton
Richard Fitton
XZXinyi Zhang
Xinyi Zhang
GHGrant Patrick Henshaw
Grant Patrick Henshaw
Heidi Díaz HernándezHeidi Díaz Hernández
Heidi Díaz Hernández
William SwanWilliam Swan
William Swan
This study provides a detailed dataset from two modern homes constructed inside an environmentally controlled chamber. These data are used to carefully calibrate a dynamic thermal simulation model of these homes. The calibrated models show good agreement with measurements taken under controlled conditions. The two case study homes, “The Future Home” and “eHome2”, were constructed within the University of Salford’s Energy House 2.0, and high-quality data were collected over eight days. The calibration process involved updating U-values, air permeability rates, and modelling refinements, such as roof ventilation, ground temperatures, and sub-floor void exchange rates, set as boundary conditions. Results demonstrated a high level of accuracy, with performance gaps in whole-house heat transfer coefficient reduced to 0.5% for “The Future Home” and 0.6% for “eHome2”, falling within aggregate heat loss test uncertainty ranges by a significant amount. The study highlights the improved accuracy of calibrated dynamic thermal simulation models, compared to results from the steady-state Standard Assessment Procedure model. By providing openly accessible calibrated models and a clearly defined methodology, this research presents valuable resources for future building performance modelling studies. The findings support the UK’s transition to dynamic modelling approaches proposed in the recently introduced Home Energy Model approach, contributing to improved prediction of energy efficiency and aligning with goals for zero carbon ready and sustainable housing development.

17 January 2025 in Sustainability
Verified
Journal Article
Open access
PDF file
CTChristopher Tsang
Christopher Tsang
Ljubomir JankovicLjubomir Jankovic
Ljubomir Jankovic
Richard FittonRichard Fitton
Richard Fitton
GHGrant Patrick Henshaw
Grant Patrick Henshaw
This paper aims to determine the optimal construction strategies for new-build houses in the UK to minimize heating energy demand and discomfort hours. This research utilizes a previously calibrated model of “The Future Home” in Energy House 2.0’s environmental chamber. Eight design variables were optimized including multiple building fabric specifications, air permeability rates, and heating setpoint temperatures. Three optimization scenarios were investigated: fixed heating setpoints, variable heating setpoints, and variable setpoints with comfort constraints. The analysis revealed that while fixed heating setpoints showed limited optimization potential, variable setpoint scenarios identified three distinct clusters of optimal solutions. The optimization consistently favored superior building fabric parameters, though air permeability solutions became more nuanced with variable heating control. When constrained to a maximum of 400 discomfort hours, solutions required elevated heating setpoints (22–23 °C) while maintaining high fabric specifications. These findings advance building optimization methodology by demonstrating the importance of heating control flexibility and comfort constraints in achieving optimal performance, while the use of a calibrated model in controlled conditions overcomes the limitations of previous studies that relied on uncalibrated or hypothetical models. As in situ field measurements of short- and long-term building performance are often subjected to disruptions, delays, and uncertainties, the building performance research under controlled conditions reported in this article will lead towards the achievement of net zero targets in a timelier manner and with more certainty.

24 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
Ljubomir JankovicLjubomir Jankovic
Ljubomir Jankovic
GHGrant Patrick Henshaw
Grant Patrick Henshaw
CTChristopher Tsang
Christopher Tsang
XZXinyi Zhang
Xinyi Zhang
Richard FittonRichard Fitton
Richard Fitton
William SwanWilliam Swan
William Swan
The heat transfer coefficient, or the HTC, is an industry-standard indicator of building energy performance. It is predicated on an assumption that it is of a constant value, and several different methods have been developed to measure and calculate the HTC as a constant. Whilst there are limited variations in the results obtained from these different methods, none of these methods consider a possibility that the HTC could be dynamically variable. Our experimental work shows that the HTC is not a constant. The experimental evidence based on our environmental chambers, which contain detached houses and in which the ambient air temperature can be controlled between −24 °C and +51 °C, with additional relative humidity control and with weather rigs that can introduce solar radiation, rain, and snow, shows that the HTC is dynamically variable. The analysis of data from the fully instrumented and monitored houses in combination with calibrated simulation models and data processing scripts based on genetic algorithm optimization provide experimental evidence of the dynamic variability of the HTC. This research increases the understanding of buildings physics properties and has the potential to change the way the heat transfer coefficient is used in building performance analysis.