Humidity change in concrete is the leading cause of concrete shrinkage. Moreover, the moisture diffusion coefficient of concrete is an essential parameter for assessing and predicting the internal moisture content of concrete. However, there is a lack of theoretical construction and experimental studies on the effect of different conditions, especially different constraints, on the moisture diffusion coefficient of concrete. Therefore, the internal humidity, pore structure parameters, and basic mechanical properties of concrete under different strength grades C30, C40, C50, and C60 (C stands for concrete and numbers indicate the strength class of the concrete), curing environments (dry and sealed curing conditions), and constraints were tested in this study. In addition, a calculation model of concrete’s internal humidity and humidity diffusion coefficient was established. The research findings show that the internal humidity of concrete decreased with age due to hydration and drying. External humidity had a significant effect on the moisture change of concrete, and the lower the external humidity, the larger the humidity diffusion coefficient and the faster the internal humidity of concrete decreases. Reinforcement (confinement) changes the pore structure parameters of the concrete, which in turn affects the transport of moisture within the concrete. The higher the reinforcement rate, the larger the pore structure parameters of the concrete, the larger the humidity diffusion coefficient, and the faster the concrete humidity decreases. The method proposed in the study can accurately predict the internal humidity of concrete using the humidity diffusion coefficient. The research results are a reference for preventing concrete shrinkage and cracking in construction.
Fracture behavior is one of the key properties to study concrete cracking under sodium chloride attack exposed to the freeze–thaw cycles environment, which is frequently neglected. In this paper, 24 single edge notch beam specimens and 24 cubes were poured. The corresponding freeze–thaw cycles test in sodium chloride solution, standard cube compressive strength of concrete test, and three-point-bending tests were carried out. The research revealed that the fracture toughness, fracture energy, relative dynamic modulus of elasticity, and standard cube compressive strength were decreased by increasing freeze–thaw cycles under sodium chloride attack, and the damage degree of concrete caused by sodium chloride solution was deeper than that of pure water. In particular, there existed good linear correlation between the fracture behavior and imposed freeze–thaw damage for various solution. Accordingly, a more reliable damage model using fracture control parameters as damage factors was proposed.
The low velocity impact load on pipes during transportation, construction and operation will cause pipeline damage and lay hidden dangers for the safety of pipeline engineering. To study the low velocity impact performance of pipes made of acrylate polymer blended with polyvinyl chloride resin for water supply (ABR), 20 sets of specimens with different heights and different masses of drop hammer were carried out to study the mechanical properties of ABR pipes. Based on the impact time curve, the energy dissipation capacity and impact peak value of ABR pipe specimens were analyzed, and the empirical calculation formula of impact force peak based on the test data is obtained by the dimensional analysis method, with a relative error ranging from −7.8% to 4.1%. Moreover, the finite element numerical simulation of ABR pipe specimens subjected to impact load is carried out, and the strain development law and failure mode of the pipe under low-speed impact load are analyzed. Therefore, the calculation formula of peak impact force and failure mode proposed in this paper can provide safety assessment methods for pipeline engineering designers and constructors.
To prevent brittle damage and improve the post-earthquake rapid repair capability of beam-column connections, a precast reduced beam section (PRBS) connection joint that can be rapidly repaired under earthquake action was proposed in this study. Four specimens, including a repaired specimen, were subjected to a quasi-static test to investigate the seismic performance and repair ability of the connection. Seismic performance indices such as the failure mode, hysteresis curve, skeleton curve, strain distribution, and ductility were obtained through observations and analyses. The results indicated that the novel connection exhibited superior load-bearing, energy dissipation, and rotation capacities, compared to the welded flange-bolted web and traditional bone-weakened connections. This novel connection effectively relocated the plastic hinge to alter the failure mode and prevent brittle damage. Additionally, rapid post-earthquake repair was achieved by replacing the dog-bone-style splice section, maintaining a high load-bearing capacity and seismic performance. Finite element (FE) models were established to analyze the mechanical behavior of the specimens, and a parametric analysis was conducted to study the influence of different parameters on the load-bearing capacity of the connection. Based on the experimental and FE analysis results, the possible yield and failure modes of the connection were analyzed, and a calculation method for the bearing capacity of the PRBS connection was proposed. A comparative result demonstrates that the proposed calculation method can accurately predict the load-carrying capacity of a connection.
The metrological performance of FBG strain sensing systems is a critical premise for the precision of plastics water support pipeline structural deformation measurement, but the strain transfer loss of FBG attached on the plastics pipe subjected by dynamic force is unclear. This paper presents the first study on the effects of strain transfer between FBG, and acrylate polymer blended with poly resin (ABR)pipe sheets loaded by static and dynamic force. Theoretical methods of dynamic strain transfer theory combine with the exponentially decaying sinusoidal shock force time course is deduced and various dynamic parameters sensitivities studies are carried out, as well as that of the geometric parameters. The result of the dynamic theory is compared with the calibration test outcomes, while the ASTR of FBG attached on ABR sheet is compared with distributed optical fiber sensors (DOFS) and other pipe materials such as PVC, concrete, and steel. Results show that the ASTR of FBG is more accurate than that of the DOFS, and the grows of ASTR depending on the paste length of FBG, the Young's modulus of the middle materials, the thickness of the middle materials and attenuation coefficient. Paste length produced the largest increase, yet the magnitude and loading speed of the external force has unexpectedly little effect on ASTR. FBG seem low error, insensitive with dynamic force and independent with the material of matrix, and this demonstrates benefits that are stronger across the board than DOFS. This is not currently recognized by standards or by most reported studies.