Xiaoyu Tong

Ms. Xiaoyu Tong


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
XWXu Wang
Xu Wang
BLBeibei Li
Beibei Li
XTXiaoyu Tong
Xiaoyu Tong
YFYong Fan
Yong Fan
SWShigeng Wang
Shigeng Wang
LLLei Liu
Lei Liu
Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (DHAP (water), DHAP (fat), DHAP (blood), DCa (water), and DCa (fat)) in the trabecular bone of vertebral bodies (T11–L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman’s correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between DHAP (water), DHAP (fat), DHAP (blood), DCa (water), and DCa (fat) and the QCT-derived BMD. DHAP (water) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with DHAP (water) ≤ 107.4 mg/cm3, respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with DHAP (water) ≤ 89.62 mg/cm3, respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with DHAP (water) having the highest diagnostic accuracy.

2 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
XTXiaoyu Tong
Xiaoyu Tong
SWShigeng Wang
Shigeng Wang
JZJingyi Zhang
Jingyi Zhang
YFYong Fan
Yong Fan
YLYijun Liu
Yijun Liu
WWWei Wei
Wei Wei
Objective: Develop two fully automatic osteoporosis screening systems using deep learning (DL) and radiomics (Rad) techniques based on low-dose chest CT (LDCT) images and evaluate their diagnostic effectiveness. Methods: In total, 434 patients who underwent LDCT and bone mineral density (BMD) examination were retrospectively enrolled and divided into the development set (n = 333) and temporal validation set (n = 101). An automatic thoracic vertebra cancellous bone (TVCB) segmentation model was developed. The Dice similarity coefficient (DSC) was used to evaluate the segmentation performance. Furthermore, the three-class Rad and DL models were developed to distinguish osteoporosis, osteopenia, and normal bone mass. The diagnostic performance of these models was evaluated using the receiver operating characteristic (ROC) curve and decision curve analysis (DCA). Results: The automatic segmentation model achieved excellent segmentation performance, with a mean DSC of 0.96 ± 0.02 in the temporal validation set. The Rad model was used to identify osteoporosis, osteopenia, and normal BMD in the temporal validation set, with respective area under the receiver operating characteristic curve (AUC) values of 0.943, 0.801, and 0.932. The DL model achieved higher AUC values of 0.983, 0.906, and 0.969 for the same categories in the same validation set. The Delong test affirmed that both models performed similarly in BMD assessment. However, the accuracy of the DL model is 81.2%, which is better than the 73.3% accuracy of the Rad model in the temporal validation set. Additionally, DCA indicated that the DL model provided a greater net benefit compared to the Rad model across the majority of the reasonable threshold probabilities Conclusions: The automated segmentation framework we developed can accurately segment cancellous bone on low-dose chest CT images. These predictive models, which are based on deep learning and radiomics, provided comparable diagnostic performance in automatic BMD assessment. Nevertheless, it is important to highlight that the DL model demonstrates higher accuracy and precision than the Rad model.

17 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
WWWei Wei
Wei Wei
SWShigeng Wang
Shigeng Wang
JZJingyi Zhang
Jingyi Zhang
XTXiaoyu Tong
Xiaoyu Tong
BLBeibei Li
Beibei Li
YLYijun Liu
Yijun Liu
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients’ body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student’s t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI ≤ 21 kg/m2, 0.56 ± 0.00 mGy and for BMI > 21 kg/m2, 1.48 ± 0.00 mGy) when compared with SDCT (for BMI ≤ 21 kg/m2, 5.24 ± 0.95 mGy and for BMI > 21 kg/m2, 6.69 ± 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI ≤ 21 kg/m2, 56.86 ± 4.73 vs. 533.58 ± 122.06 mGy.cm, and for BMI > 21 kg/m2, 167.02 ± 38.76 vs. 746.01 ± 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI ≤ 21 kg/m2) and 77.68% (for BMI > 21 kg/m2), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.