Shigeng Wang

Dr. Shigeng Wang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2023 in Academic Radiology
Verified
Journal Article
Open access
SWShigeng Wang
Shigeng Wang
XTXiaoyu Tong
Xiaoyu Tong
YFYong Fan
Yong Fan
MHMengting Hu
Mengting Hu
JCJingjing Cui
Jingjing Cui
XXin Fang
Xin Fang
To develop an intelligent diagnostic model for osteoporosis screening based on low-dose chest computed tomography (LDCT). The model incorporates automatic deep-learning thoracic vertebrae of cancellous bone (TVCB) segmentation model and radiomics analysis. A total of 442 participants who underwent both LDCT and quantitative computed tomography (QCT) examinations were enrolled and were randomly allocated to the training, internal testing, and external testing cohorts. The TVCB automatic segmentation model was trained using VB-Net. The accuracy of the segmentation was evaluated using the Dice coefficient. Predictive models for assessing bone mineral density (BMD) were constructed utilizing radiomics analysis based on automatic segmentation (ASeg model) and manual segmentation (MSeg model), respectively. The BMD predictive model based on ASeg and MSeg included the identification of normal and abnormal BMD (first-level model), and osteopenia and osteoporosis (second-level model). The diagnostic performance of the radiomics models were evaluated using the area under the curve (AUC), sensitivity and specificity. The Dice coefficients of the TVCB segmentation model in the internal and external testing cohorts were found to be 0.988 ± 0.014 and 0.939 ± 0.034, respectively. In the first-level model, the AUC of the ASeg model exhibited comparable performance to that of the MSeg model for both the internal (0.985 vs. 0.946, P = 0.080) and external (0.965 vs. 0.955, P = 0.724) testing cohorts. Similarly, in the second-level model, the AUC of the ASeg model was found to be comparable to that of the MSeg model for both the internal (0.933 vs. 0.920, P = 0.794) and external (0.907 vs. 0.892, P = 0.805) testing cohorts. A fully automated pipeline for TVCB segmentation and BMD assessment with radiomics analysis can be used for opportunistic BMD screening in chest LDCT.

1 April 2024 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
SWShigeng Wang
Shigeng Wang
XTXiaoyu Tong
Xiaoyu Tong
QCQiye Cheng
Qiye Cheng
QXQingzhu Xiao
Qingzhu Xiao
JCJingjing Cui
Jingjing Cui
XFXin Fang
Xin Fang
Background: Osteoporosis, a disease stemming from bone metabolism irregularities, affects approximately 200 million people worldwide. Timely detection of osteoporosis is pivotal in grappling with this public health challenge. Deep learning (DL), emerging as a promising methodology in the field of medical imaging, holds considerable potential for the assessment of bone mineral density (BMD). This study aimed to propose an automated DL framework for BMD assessment that integrates localization, segmentation, and ternary classification using various dominant convolutional neural networks (CNNs). Methods: In this retrospective study, a cohort of 2,274 patients underwent chest computed tomography (CT) was enrolled from January 2022 to June 2023 for the development of the integrated DL system. The study unfolded in 2 phases. Initially, 1,025 patients were selected based on specific criteria to develop an automated segmentation model, utilizing 2 VB-Net networks. Subsequently, a distinct cohort of 902 patients was employed for the development and testing of classification models for BMD assessment. Then, 3 distinct DL network architectures, specifically DenseNet, ResNet-18, and ResNet-50, were applied to formulate the 3-classification BMD assessment model. The performance of both phases was evaluated using an independent test set consisting of 347 individuals. Segmentation performance was evaluated using the Dice similarity coefficient; classification performance was appraised using the receiver operating characteristic (ROC) curve. Furthermore, metrics such as the area under the curve (AUC), accuracy, and precision were meticulously calculated. Results: In the first stage, the automatic segmentation model demonstrated excellent segmentation performance, with mean Dice surpassing 0.93 in the independent test set. In the second stage, both the DenseNet and ResNet-18 demonstrated excellent diagnostic performance in detecting bone status. For osteoporosis, and osteopenia, the AUCs were as follows: DenseNet achieved 0.94 [95% confidence interval (CI): 0.91–0.97], and 0.91 (95% CI: 0.87–0.94), respectively; ResNet-18 attained 0.96 (95% CI: 0.92–0.98), and 0.91 (95% CI: 0.87–0.94), respectively. However, the ResNet-50 model exhibited suboptimal diagnostic performance for osteopenia, with an AUC value of only 0.76 (95% CI: 0.69–0.80). Alterations in tube voltage had a more pronounced impact on the performance of the DenseNet. In the independent test set with tube voltage at 100 kVp images, the accuracy and precision of DenseNet decreased on average by approximately 14.29% and 18.82%, respectively, whereas the accuracy and precision of ResNet-18 decreased by about 8.33% and 7.14%, respectively. Conclusions: The state-of-the-art DL framework model offers an effective and efficient approach for opportunistic osteoporosis screening using chest CT, without incurring additional costs or radiation exposure.

16 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
XWXu Wang
Xu Wang
BLBeibei Li
Beibei Li
XTXiaoyu Tong
Xiaoyu Tong
YFYong Fan
Yong Fan
SWShigeng Wang
Shigeng Wang
LLLei Liu
Lei Liu
Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (DHAP (water), DHAP (fat), DHAP (blood), DCa (water), and DCa (fat)) in the trabecular bone of vertebral bodies (T11–L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman’s correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between DHAP (water), DHAP (fat), DHAP (blood), DCa (water), and DCa (fat) and the QCT-derived BMD. DHAP (water) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with DHAP (water) ≤ 107.4 mg/cm3, respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with DHAP (water) ≤ 89.62 mg/cm3, respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with DHAP (water) having the highest diagnostic accuracy.

2 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
XTXiaoyu Tong
Xiaoyu Tong
SWShigeng Wang
Shigeng Wang
JZJingyi Zhang
Jingyi Zhang
YFYong Fan
Yong Fan
YLYijun Liu
Yijun Liu
WWWei Wei
Wei Wei
Objective: Develop two fully automatic osteoporosis screening systems using deep learning (DL) and radiomics (Rad) techniques based on low-dose chest CT (LDCT) images and evaluate their diagnostic effectiveness. Methods: In total, 434 patients who underwent LDCT and bone mineral density (BMD) examination were retrospectively enrolled and divided into the development set (n = 333) and temporal validation set (n = 101). An automatic thoracic vertebra cancellous bone (TVCB) segmentation model was developed. The Dice similarity coefficient (DSC) was used to evaluate the segmentation performance. Furthermore, the three-class Rad and DL models were developed to distinguish osteoporosis, osteopenia, and normal bone mass. The diagnostic performance of these models was evaluated using the receiver operating characteristic (ROC) curve and decision curve analysis (DCA). Results: The automatic segmentation model achieved excellent segmentation performance, with a mean DSC of 0.96 ± 0.02 in the temporal validation set. The Rad model was used to identify osteoporosis, osteopenia, and normal BMD in the temporal validation set, with respective area under the receiver operating characteristic curve (AUC) values of 0.943, 0.801, and 0.932. The DL model achieved higher AUC values of 0.983, 0.906, and 0.969 for the same categories in the same validation set. The Delong test affirmed that both models performed similarly in BMD assessment. However, the accuracy of the DL model is 81.2%, which is better than the 73.3% accuracy of the Rad model in the temporal validation set. Additionally, DCA indicated that the DL model provided a greater net benefit compared to the Rad model across the majority of the reasonable threshold probabilities Conclusions: The automated segmentation framework we developed can accurately segment cancellous bone on low-dose chest CT images. These predictive models, which are based on deep learning and radiomics, provided comparable diagnostic performance in automatic BMD assessment. Nevertheless, it is important to highlight that the DL model demonstrates higher accuracy and precision than the Rad model.

17 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
WWWei Wei
Wei Wei
SWShigeng Wang
Shigeng Wang
JZJingyi Zhang
Jingyi Zhang
XTXiaoyu Tong
Xiaoyu Tong
BLBeibei Li
Beibei Li
YLYijun Liu
Yijun Liu
Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients’ body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student’s t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI ≤ 21 kg/m2, 0.56 ± 0.00 mGy and for BMI > 21 kg/m2, 1.48 ± 0.00 mGy) when compared with SDCT (for BMI ≤ 21 kg/m2, 5.24 ± 0.95 mGy and for BMI > 21 kg/m2, 6.69 ± 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI ≤ 21 kg/m2, 56.86 ± 4.73 vs. 533.58 ± 122.06 mGy.cm, and for BMI > 21 kg/m2, 167.02 ± 38.76 vs. 746.01 ± 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI ≤ 21 kg/m2) and 77.68% (for BMI > 21 kg/m2), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.