Johannes A. J. Huber

Dr. Johannes A. J. Huber

Engineering Science and Mathematics, Luleå University of Technology, Luleå, Norrbotten, Sweden
orcid
Associate Senior Lecturer at Luleå University of Technology,...

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2017 in Wood Material Science & Engineering
Verified
Journal Article
Open access
Johannes A. J. HuberJohannes A. J. Huber
Johannes A. J. Huber
MEMats Ekevad
Mats Ekevad
UGUlf Arne Girhammar
Ulf Arne Girhammar
SBSven Berg
Sven Berg
Timber buildings are increasing in their dimensions. Structural robustness is imperative for all buildings and specifically important for tall buildings. Lives can be saved if disproportionate collapse can be avoided after a catastrophic event (e.g. accident, terrorism). The literature about robustness is comprehensive concerning concrete and steel buildings, but is rather limited regarding timber. This paper reviews robustness in general and robustness of timber buildings in particular. Robustness is an intrinsic structural property, enhancing global tolerance to local failures, regardless of the cause. A deterministic approach to assess robustness is to remove certain load-bearing elements from the structure and compare the consequences to given limits. Design methods for robustness may be direct by assessing effects of local failure, or indirect by following guidelines. For robust timber buildings, the connections are the key aspects. Usually, metal connectors may provide the required joint ductility. For robust light timber-frame construction, rim beams may be designed. For timber posts and beams and cross laminated timber, guidance regarding robustness is scarce, but in some aspects they seem to be similar to steel frames and precast concrete. Future research should assess the capacity of connections, and evaluate the adequacy of seismic connectors for robust timber buildings.

1 May 2020 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Verified
Journal Article
Open access
Johannes A. J. HuberJohannes A. J. Huber
Johannes A. J. Huber
MEMats Ekevad
Mats Ekevad
UGUlf Arne Girhammar
Ulf Arne Girhammar
SBSven Berg
Sven Berg
Multi-storey cross-laminated timber (CLT) buildings are a comparatively recent construction type. Knowledge concerning the performance of CLT buildings regarding the prevention of disproportionate collapse after unforeseeable events (e.g. accidents or acts of terrorism) is not as refined as that for concrete and steel buildings. In particular, alternative load paths (ALPs) after the removal of a wall panel in platform-framed variants have not yet been studied in detail. The goal of this work was therefore to study ALPs in CLT buildings. An eight-storey bay of an existing building was evaluated by conducting a non-linear static pushdown analysis in a finite element analysis on three representative storeys. The analyses accounted for single fastener behaviour, timber crushing, friction, brittle failure and large deformations. The force–deformation behaviours elicited under the pushdown analyses were subsequently inserted in a simplified dynamic model to evaluate the transient response of the entire bay. Four ALPs were identified in this case – shear resistance in the floor panels, arching action of the walls, catenary action in the floor panels and hanging action from the roof. The dynamic analysis did not show a collapse, unless the inter-compartment stiffness was significantly reduced. The resistance mechanisms are described in this paper, which may provide information for improved building design.

7 March 2019 in Wood Material Science & Engineering
Verified
Journal Article
Open access
SBSven Berg
Sven Berg
JTJonas Turesson
Jonas Turesson
MEMats Ekevad
Mats Ekevad
Johannes A. J. HuberJohannes A. J. Huber
Johannes A. J. Huber
Cross laminated timber (CLT) is a wood panelling building system that is used in construction, e.g. for floors, walls and beams. Because of the increased use of CLT, it is important to have accurate simulation models. CLT systems are simulated with one-dimensional and two-dimensional (2D) methods because they are fast and deliver practical results. However, because non-edge-glued panels cannot be modelled under 2D, these results may differ from more accurate calculations in three dimensions (3D). In this investigation, CLT panels with different width-to-thickness ratios for the boards have been simulated using the finite element method. The size of the CLT-panels was 3.0 m × 3.9 m and they had three and five laminate layers oriented 0°–90°–0° and 0°–90°–0°–90°–0°. The thicknesses of the boards were 33.33, 40.0, and 46.5 mm. The CLT panel deformation was compared by using a distributed out-of-plane load. Results showed that panels with narrow boards were less stiff than wide boards for the four-sided support setup. The results also showed that 2D models underestimate the displacement when compared to 3D models. By adjusting the stiffness factor k88, the 2D model displacement became more comparable to the 3D model.

1 July 2022 in Journal of Structural Engineering
Verified
Journal Article
Open access
PDF file
HBHercend Mpidi Bita
Hercend Mpidi Bita
Johannes A. J. HuberJohannes A. J. Huber
Johannes A. J. Huber
PPPedro Palma
Pedro Palma
Thomas TannertThomas Tannert
Thomas Tannert
The expanding height of multistory mass timber buildings makes the development of guidance to prevent disproportionate collapse an increasingly important area of engineering design; however, there is no guidance available in building codes or design standards on how to prevent disproportionate collapse of multistory mass timber buildings. In this paper, practical project-specific solutions applied in constructed prominent multistory mass timber buildings to prevent disproportionate collapse are presented. Various approaches have been successfully used for different construction types of multistory mass timber buildings to decrease the potential risk of disproportionate collapse, such as using walls above supports as deep beams and using columns to carry tension forces and hold the floor below in case a supporting column or wall is damaged. Then, recent and ongoing research in the field of prevention of disproportionate collapse of multistory timber buildings is reviewed. Such research is mostly based on numerical simulations of element removal scenarios and pushdown experiments on floor systems and connections and provides valuable insights and guidance to designers on important structural aspects regarding the prevention of disproportionate collapse in multistory mass timber buildings. Finally, the draft provisions for an upcoming standard related to the prevention of disproportionate collapse are reviewed, and the conclusions regarding the state of the art are presented.


22 June 2024 in Drying Technology
Verified
Journal Article
Open access
EHEbrahim Hajian
Ebrahim Hajian
Johannes A. J. HuberJohannes A. J. Huber
Johannes A. J. Huber
LHLars Hansson
Lars Hansson
DSDick Sandberg
Dick Sandberg