Ben Baker

Mr. Ben Baker

PATH, Seattle, Washington, USA
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Vaccine: X
Verified
Journal Article
Open access
BMBrian K Meyer
Brian K Meyer
MKMark A.F. Kendall
Mark A.F. Kendall
DWDonna M. Williams
Donna M. Williams
ABAndrew J. Bett
Andrew J. Bett
SDSheri Dubey
Sheri Dubey
ABAkhilesh Bhambhani
Akhilesh Bhambhani
The human papillomavirus (HPV) 9-valent, recombinant vaccine (Gardasil™9) helps protect young adults (males and females) against anogenital cancers and genital warts caused by certain HPV genotypes (ref. Gardasil™9 insert). This vaccine is administered intramuscularly (IM). The aim of this study was to determine preclinically whether intradermal (ID) vaccination with an unadjuvanted 9-valent recombinant HPV vaccine using a first-generation ID delivery device, the Nanopatch™, could enhance vaccine immunogenicity compared with the traditional ID route (Mantoux technique). IM injection of HPV VLPs formulated with Merck & Co., Inc., Kenilworth, NJ, USA Alum Adjuvant (MAA) were included in the rhesus study for comparison. The Nanopatch™ prototype contains a high-density array comprised of 10,000 microprojections/cm2, each 250 µm long. It was hypothesized the higher density array with shallower ID delivery may be superior to the Mantoux technique. To test this hypothesis, HPV VLPs without adjuvant were coated on the Nanopatch™, stability of the Nanopatch™ with unadjuvanted HPV VLPs were evaluated under accelerated conditions, skin delivery was verified using radiolabelled VLPs or FluoSpheres®, and the immune response and skin site reaction with the Nanopatch™ was evaluated in rhesus macaques. The immune response induced by Nanopatch™ administration, measured as HPV-specific binding antibodies, was similar to that induced using the Mantoux technique. It was also observed that a lower dose of unadjuvanted HPV VLPs delivered with the first-generation Nanopatch™ and applicator or Mantoux technique resulted in an immune response that was significantly lower compared to a higher-dose of alum adjuvanted HPV VLPs delivered IM in rhesus macaques. The study also indicated unadjuvanted HPV VLPs could be delivered with the first-generation Nanopatch™ and applicator to the skin in 15 s with a transfer efficiency of approximately 20%. This study is the first demonstration of patch administration in non-human primates with a vaccine composed of HPV VLPs.

28 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DMDavid Muller
David Muller
JHJoakim Henricson
Joakim Henricson
Ben BakerBen Baker
Ben Baker
TTTotte Togö
Totte Togö
CFCesar M. Jayashi Flores
Cesar M. Jayashi Flores
CAChris D. Anderson
Chris D. Anderson
The development of microarray patches for vaccine application has the potential to revolutionise vaccine delivery. Microarray patches (MAP) reduce risks of needle stick injury, do not require reconstitution and have the potential to enhance immune responses using a fractional vaccine dose. To date, the majority of research has focused on vaccine delivery with little characterisation of local skin response and recovery. Here we study in detail the immediate local skin response and recovery of the skin post high density MAP application in 12 individuals receiving 3 MAPs randomly assigned to the forearm and upper arm. Responses were characterised by clinical scoring, dermatoscopy, evaporimetry and tissue viability imaging (TiVi). MAP application resulted in punctures in the epidermis, a significant transepidermal water loss (TEWL), the peak TEWL being concomitant with peak erythema responses visualised by TiVi. TEWL and TiVi responses reduced over time, with TEWL returning to baseline by 48 h and erythema fading over the course of a 7 day period. As MAPs for vaccination move into larger clinical studies more variation of individual subject phenotypic or disease propensity will be encountered which will require consideration both in regard to reliability of dose delivery and degree of inherent skin response.

17 November 2023 in Vaccines
Verified
Journal Article
Open access
PDF file
Ben BakerBen Baker
Ben Baker
IBImogen Margaret Bermingham
Imogen Margaret Bermingham
ILIndika Leelasena
Indika Leelasena
JHJulian Hickling
Julian Hickling
PYPaul Young
Paul Young
AFAngus H. Forster
Angus H. Forster
Microarray patches (MAPs) have the potential to be a safer, more acceptable, easier-to-use, and more cost-effective means for the administration of vaccines than injection by needle and syringe. Here, we report findings from a randomized, partially double-blinded, placebo-controlled Phase I trial using the Vaxxas high-density MAP (HD-MAP) to deliver a measles rubella (MR) vaccine. Healthy adults (N = 63, age 18–50 years) were randomly assigned 1:1:1:1 to four groups: uncoated (placebo) HD-MAPs, low-dose MR HD-MAPs (~3100 median cell-culture infectious dose [CCID50] measles, ~4300 CCID50 rubella); high-dose MR-HD-MAPs (~9300 CCID50 measles, ~12,900 CCID50 rubella); or a sub-cutaneous (SC) injection of an approved MR vaccine, MR-Vac (≥1000 CCID50 per virus). The MR vaccines were stable and remained viable on HD-MAPs when stored at 2–8 °C for at least 24 months. When MR HD-MAPs stored at 2–8 °C for 24 months were transferred to 40 °C for 3 days in a controlled temperature excursion, loss of potency was minimal, and MR HD-MAPs still met World Health Organisation (WHO) specifications. MR HD-MAP vaccination was safe and well-tolerated; any systemic or local adverse events (AEs) were mild or moderate. Similar levels of binding and neutralizing antibodies to measles and rubella were induced by low-dose and high-dose MR HD-MAPs and MR-Vac. The neutralizing antibody seroconversion rates on day 28 after vaccination for the low-dose HD-MAP, high-dose HD-MAP and MR-Vac groups were 37.5%, 18.8% and 35.7%, respectively, for measles, and 37.5%, 25.0% and 35.7%, respectively, for rubella. Most participants were seropositive for measles and rubella antibodies at baseline, which appeared to negatively impact the number of participants that seroconverted to vaccines delivered by either route. The data reported here suggest HD-MAPs could be a valuable means for delivering MR-vaccine to hard-to-reach populations and support further development. Clinical trial registry number: ACTRN12621000820808.

7 August 2020 in npj Vaccines
Verified
Journal Article
Open access
PDF file
JMJamie-Lee S. Mills
Jamie-Lee S. Mills
CFCesar M. Jayashi Flores
Cesar M. Jayashi Flores
SRSimone Reynolds
Simone Reynolds
CWChristine Wun
Christine Wun
ACAinslie Calcutt
Ainslie Calcutt
MGMichael F. Good
Michael F. Good
We evaluated vaccination against Streptococcus pyogenes with the candidate vaccine, J8-DT, delivered by a high-density microarray patch (HD-MAP). We showed that vaccination with J8-DT eluted from a coated HD-MAP (J8-DT/HD-MAP), induced similar total IgG responses to that generated by vaccination with J8-DT adjuvanted with Alum (J8-DT/Alum). We evaluated the effect of dose reduction and the number of vaccinations on the antibody response profile of vaccinated mice. A reduction in the number of vaccinations (from three to two) with J8-DT/HD-MAP induced comparable antibody responses to three vaccinations with intramuscular J8-DT/Alum. Vaccine-induced protection against an S. pyogenes skin challenge was assessed. J8-DT/HD-MAP vaccination led to a significant reduction in the number of S. pyogenes colony forming units in skin (92.9%) and blood (100%) compared to intramuscular vaccination with unadjuvanted J8-DT. The protection profile was comparable to that of intramuscular J8-DT/Alum. J8-DT/HD-MAP induced a shift in the antibody isotype profile, with a bias towards Th1-related isotypes, compared to J8-DT/Alum (Th2 bias). Based on the results of this study, the use of J8-DT/HD-MAP should be considered in future clinical development and control programs against S. pyogenes. Furthermore, the innate characteristics of the technology, such as vaccine stability and increased coverage, ease of use, reduction of sharp waste and the potential reduction of dose may be advantageous compared to current vaccination methods.

2 January 2023 in Human Vaccines & Immunotherapeutics
Verified
Journal Article
Open access
Ben BakerBen Baker
Ben Baker
EHE. Hacker
E. Hacker
GSG. Siller
G. Siller
MLM. Lee
M. Lee
NMN. Mursaliyev
N. Mursaliyev
AFAngus H. Forster
Angus H. Forster
The high-density microneedle array patch (HD-MAP) is a novel vaccine delivery system with potential for self-administered vaccination. In this study, Vaxxas HD-MAPs were applied by both a trained user and self-administered with application sites compared to determine the response of skin and the level of engagement of the HD-MAP with human skin. Twenty healthy participants were enrolled, and the response of skin including erythema was observed at all application sites and no difference was found between trained user or self-administered applications. The majority of participants (70%) preferred the deltoid upper arm application site for applying HD-MAPs. Fluorescent dermatoscope images confirmed HD-MAPs engaged the skin surface and scanning electron microscopy (SEM) image analysis exhibited similar delivery characteristics for the upper arm and forearm sites when applied by either a trained user or self-administered. This study showed that noninvasive methods including dermatoscopy and SEM image analysis were able to estimate the engagement of HD-MAPs with human skin. HD-MAP self-vaccination technology has a unique proposition in pandemic preparedness by alleviating the need for health-care workers to administer vaccines, however greater awareness and understanding of the potential of this technology is required. GRAPHICAL ABSTRACT

7 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Ben BakerBen Baker
Ben Baker
IBImogen Margaret Bermingham
Imogen Margaret Bermingham
ILIndika Leelasena
Indika Leelasena
JHJulian Hickling
Julian Hickling
PYPaul Young
Paul Young
AFAngus H. Forster
Angus H. Forster
Microarray patches (MAPs) have the potential to be a safer, more acceptable, easier to use, and more cost-effective means for the administration of vaccines than injection by needle and syringe. Here, we report findings from a randomized, partially double-blind, placebo-controlled Phase I trial using the Vaxxas high-density MAP (HD-MAP) to deliver a measles rubella (MR) vaccine. Healthy adults (N = 63, age 18–50 years) were randomly assigned 1:1:1:1 to four groups: uncoated (placebo) HD-MAPs, low-dose MR HD-MAPs (~3,100 median cell-culture infectious dose [CCID50] measles, ~4,300 CCID50 rubella); high dose MR-HD-MAPs (~9,300 CCID50 measles, ~12,900 CCID50 rubella); or a sub-cutaneous (SC) injection of an approved MR vaccine, MR-Vac (≥1,000 CCID50 per virus). The MR vaccines were stable and remained viable on HD-MAPs when stored at 2–8°C for at least 24 months. When MR HD-MAPs stored at 2–8°C for 24 months were transferred to 40°C for 3 days in a controlled temperature excursion, loss of potency was minimal, and MR HD-MAPs still met World Health Organisation (WHO) specifications. MR HD-MAP vaccination was safe and well-tolerated; any systemic or local adverse events (AEs) were mild or moderate. Similar levels of binding and neutralizing antibodies to measles and rubella were induced by low-dose and high-dose MR HD-MAPs and MR-Vac. The neutralizing antibody seroconversion rates at day 28 after vaccination for the low-dose HD-MAP, high-dose HD-MAP and MR-Vac groups were 37.5%, 18.8% and 35.7% respectively for measles and 37.5%, 25.0% and 35.7% respectively for rubella. Most participants were seropositive for measles and rubella antibodies at baseline, which appeared to negatively impact the number of participants that seroconverted to vaccines delivered by either route. The data reported here suggest HD-MAPs could be a valuable means for delivering MR-vaccine to hard-to-reach populations and support further development. Clinical trial registry number: ACTRN12621000820808.