Prefabricated beam–column connections are the most vulnerable components of prefabricated buildings during earthquake events. The seismic performance of the beam–column connection is functional as the critical component plays a key role in structural safety. This study aimed to develop a novel hybrid prefabricated concrete (HPC) connection, combining with wet and dry connection techniques, to enhance the seismic performance of prefabricated concrete frames. A quasi-static experimental investigation was carried out to examine the seismic performance of the proposed connection. Two full-scale prefabricated connection specimens utilizing the proposed HPC connection and another code-defined monolithic prefabricated concrete (PC) connection were tested under cyclic loading, keeping the axial load on the column constant. The ductility, stiffness degradation, energy dissipation capacity, post-tensioned force, and residual displacement were obtained based on the experimental output. The results indicated that the HPC connection developed had high construction efficiency and better seismic performance than the conventional PC connection. The strength and energy dissipation capacity were significantly improved by up to 52% and 10%, respectively. The cracking and stiffness degradation were well-controlled.
To study the seismic strengthening of damaged reinforced concrete (RC) frames using CFRP sheets, this study designed and tested the scaled 2-bay and 2-storey RC frame specimens. After applying a low cyclic horizontal load to simulate the initial damage to the specimen in an earthquake disaster, CFRP was used to strengthen the joints of the damaged RC frame. Pseudo-static tests of strengthened specimens and counterpart specimens were then carried out. Seismic performance, including stiffness, load capacity, ductility and energy dissipation were further analyzed. The failure mode of strengthened RC frame structures showed excellent ductility. The results demonstrated that the strengthening method involving wrapping CFRP can significantly improve the maximum horizontal bearing capacity, initial stiffness and energy dissipation capacity of the non-ductile reinforced concrete frame structure. The average displacement ductility coefficient of strengthened specimen can be enhanced to 3.41 compared with that of counterpart specimen (3.00). The pushover analysis based on the OpenSees model determined that the prototype frame with CFRP strengthening can maintain structural integrity and safety, with its maximum interstorey displacement angle below the limit of seismic specification (i.e., 1/50 in a severe earthquake). This study can contribute to the development of practical and efficient methods for restoring and improving the performance of damaged RC frames in seismic-prone regions.
This paper presents the seismic behavior of a precast concrete frame with buckling-restrained braces (BRBs-PC frame) and analyzes the structural failure mode caused by the horizontal force of BRBs. Two half-scale PC frames, with and without BRBs, were designed and tested using a pseudo-static test. During the test, the BRBs-PC frame exhibited a failure mode of beam-hinge with BRBs. When the BRBs-PC frame yielded, the ratio of the BRB’s energy dissipation to total energy dissipation was 65%. Cracks appeared on the column’s superimposed surfaces. The ultimate bearing capacity and energy dissipation of the BRBs-PC frame were significantly improved.
A typical megaframe structure has a high lateral stiffness and is excellent for high‐rise structures. However, this high stiffness can lead to poor seismic response of a structure. Seismic isolation technology is a mature and cheap vibration control method that is used for vibration reduction in megaframes. This paper introduces a megaframe structure based on substructure combined isolation. The structure consists of two parts. The main body is a megaframe, and the substructure is the subframe with the combined isolation layer arranged at the bottom of the subframe. The seismic performance of this structure system was evaluated by performing shaking table tests of two megaframe model structures. The responses of the deformation, acceleration, and shear of the structure were measured. The dynamic behaviors of the structure with or without the combined isolation layer when exposed to single and bidirectional near‐fault and far‐fault ground motions with different peak values were investigated. The results showed that the combined isolation layer can reduce the bidirectional seismic response of the main frame and subframe. The acceleration, base shear, and displacement responses had similar vibration reduction trends for the two model structures, and the structural responses under bidirectional earthquake were generally greater than that under a single directional earthquake. The near‐fault pulse effect increased the seismic response of the structure. The increase of the predominant period of ground motion also increased the seismic response of the structure.