Shen Shi

Shen Shi

Auto-generated profile, based on publicly available information

Shen Shi

College of Civil Engineering

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
HMHuimin Mao
Huimin Mao
XYXueyuan Yan
Xueyuan Yan
XNXiangliang Ning
Xiangliang Ning
SSShen Shi
Shen Shi
In this work, a displacement‐amplified torsional damper (DATD) is proposed for improving the seismic capacity of the beam‐column joints of a frame structure. The proposed DATD uses common steel, lead, and high‐damping rubber. This damper exhibits good energy dissipation under small earthquakes. Under strong earthquakes and large displacements, the strengthening of the high‐damping rubber can improve the overall stiffness of the damper and increase the energy dissipation. In order to investigate the performance of the proposed DATD, theoretical analyses, simulations, and cyclic loading tests were performed, and their results were compared, showing an overall good agreement.

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
XYXueyuan Yan
Xueyuan Yan
WCWeihong Chen
Weihong Chen
SSShen Shi
Shen Shi
XWXuan Wang
Xuan Wang
A typical megaframe structure has a high lateral stiffness and is excellent for high‐rise structures. However, this high stiffness can lead to poor seismic response of a structure. Seismic isolation technology is a mature and cheap vibration control method that is used for vibration reduction in megaframes. This paper introduces a megaframe structure based on substructure combined isolation. The structure consists of two parts. The main body is a megaframe, and the substructure is the subframe with the combined isolation layer arranged at the bottom of the subframe. The seismic performance of this structure system was evaluated by performing shaking table tests of two megaframe model structures. The responses of the deformation, acceleration, and shear of the structure were measured. The dynamic behaviors of the structure with or without the combined isolation layer when exposed to single and bidirectional near‐fault and far‐fault ground motions with different peak values were investigated. The results showed that the combined isolation layer can reduce the bidirectional seismic response of the main frame and subframe. The acceleration, base shear, and displacement responses had similar vibration reduction trends for the two model structures, and the structural responses under bidirectional earthquake were generally greater than that under a single directional earthquake. The near‐fault pulse effect increased the seismic response of the structure. The increase of the predominant period of ground motion also increased the seismic response of the structure.