Objective. Mask positive-pressure ventilation could lead to lung ventilation inhomogeneity, potentially inducing lung function impairments, when compared with spontaneous breathing. Lung ventilation inhomogeneity can be monitored by chest electrical impedance tomography (EIT), which could increase our understanding of mask ventilation-derived respiratory mechanics. We hypothesized that the two-handed mask holding ventilation technique resulted in better lung ventilation, reflected by respiratory mechanics, when compared with the one-handed mask holding technique. Approach. Elective surgical patients with healthy lungs were randomly assigned to receive either one-handed mask holding (one-handed group) or two-handed mask holding (two-handed group) ventilation. Mask ventilation was performed by certified registered anesthesiologists, during which the patients were mechanically ventilated using the pressure-controlled mode. EIT was used to assess respiratory mechanics, including ventilation distribution, global and regional respiratory system compliance ( CRS ), expiratory tidal volume (TVe) and minute ventilation volume. Hemodynamic parameters and the PaO 2 -FiO 2 ratio were also recorded. Main results. Eighty adult patients were included in this study. Compared with spontaneous ventilation, mask positive-pressure ventilation caused lung ventilation inhomogeneity with both one-handed(global inhomogeneity index: 0.40 ± 0.07 versus 0.50 ± 0.15; P < 0.001) and two-handed mask holding (0.40 ± 0.08 versus 0.50 ± 0.13; P < 0.001). There were no differences in the global inhomogeneity index ( P = 0.948) between the one-handed and two-handed mask holding. Compared with the one-handed mask holding, the two-handed mask holding was associated with higher TVe (552.6 ± 184.2 ml versus 672.9 ± 156.6 ml, P = 0.002) and higher global CRS (46.5 ± 16.4 ml/cmH 2 O versus 53.5 ± 14.5 ml/cmH 2 O, P = 0.049). No difference in PaO 2 -FiO 2 ratio was found between both holding techniques ( P = 0.743). Significance. The two-handed mask holding technique could not improve the inhomogeneity of lung ventilation when monitored by EIT during mask ventilation although it obtained larger expiratory tidal volumes than the one-handed mask holding technique.
Individualized positive end-expiratory pressure (PEEP) combined with recruitment maneuvers improves intraoperative oxygenation in individuals undergoing robot-assisted prostatectomy. However, whether electrical impedance tomography (EIT)-guided individualized PEEP without recruitment maneuvers can also improve intraoperative oxygenation is unknown. To test this, fifty-six male patients undergoing elective robot-assisted laparoscopic prostatectomy were randomly assigned to either individualized PEEP (Group PEEPIND, n = 28) or a control with a fixed PEEP of 5 cm H2O (Group PEEP5, n = 28). Individualized PEEP was guided by EIT after placing the patients in the Trendelenburg position and performing intraperitoneal insufflation. Patients in Group PEEPIND maintained individualized PEEP without intermittent recruitment maneuvers, and those in Group PEEP5 maintained a PEEP of 5 cm H2O intraoperatively. Both groups were extubated in a semi-sitting position once the extubation criteria were met. The primary outcome was arterial oxygen partial pressure (PaO2)/inspiratory oxygen fraction (FiO2) prior to extubation. Other outcomes included intraoperative driving pressure, plateau pressure and dynamic, respiratory system compliance, and the incidence of postoperative hypoxemia in the post-operative care unit (PACU). Our results showed that the intraoperative median for PEEPIND was 16 cm H2O (ranging from 12 to 18 cm H2O). EIT-guided PEEPIND was associated with higher PaO2/FiO2 before extubation compared to PEEP5 (71.6 ± 10.7 vs. 56.8 ± 14.1 kPa, p = 0.003). Improved oxygenation extended into the PACU with a lower incidence of postoperative hypoxemia (3.8% vs. 26.9%, p = 0.021). Additionally, PEEPIND was associated with lower driving pressures (12.0 ± 3.0 vs. 15.0 ± 4.4 cm H2O, p = 0.044) and better compliance (44.5 ± 12.8 vs. 33.6 ± 9.1 mL/cm H2O, p = 0.017). Our data indicated that individualized PEEP guided by EIT without intraoperative recruitment maneuvers also improved perioperative oxygenation in patients undergoing robot-assisted laparoscopic radical prostatectomy, which could benefit patients with the risk of intraoperative hemodynamic instability caused by recruitment maneuvers. Trial registration: China Clinical Trial Registration Center Identifier: ChiCTR2100053839. This study was registered on 1 December 2021. The first patient was recruited on 15 December 2021.