Ling ling Gao

Dr. Ling ling Gao


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
LPLili Pan
Lili Pan
LYLi Yang
Li Yang
LGLing ling Gao
Ling ling Gao
Zhanqi ZhaoZhanqi Zhao
Zhanqi Zhao
JZJun Zhang
Jun Zhang
Individualized positive end-expiratory pressure (PEEP) combined with recruitment maneuvers improves intraoperative oxygenation in individuals undergoing robot-assisted prostatectomy. However, whether electrical impedance tomography (EIT)-guided individualized PEEP without recruitment maneuvers can also improve intraoperative oxygenation is unknown. To test this, fifty-six male patients undergoing elective robot-assisted laparoscopic prostatectomy were randomly assigned to either individualized PEEP (Group PEEPIND, n = 28) or a control with a fixed PEEP of 5 cm H2O (Group PEEP5, n = 28). Individualized PEEP was guided by EIT after placing the patients in the Trendelenburg position and performing intraperitoneal insufflation. Patients in Group PEEPIND maintained individualized PEEP without intermittent recruitment maneuvers, and those in Group PEEP5 maintained a PEEP of 5 cm H2O intraoperatively. Both groups were extubated in a semi-sitting position once the extubation criteria were met. The primary outcome was arterial oxygen partial pressure (PaO2)/inspiratory oxygen fraction (FiO2) prior to extubation. Other outcomes included intraoperative driving pressure, plateau pressure and dynamic, respiratory system compliance, and the incidence of postoperative hypoxemia in the post-operative care unit (PACU). Our results showed that the intraoperative median for PEEPIND was 16 cm H2O (ranging from 12 to 18 cm H2O). EIT-guided PEEPIND was associated with higher PaO2/FiO2 before extubation compared to PEEP5 (71.6 ± 10.7 vs. 56.8 ± 14.1 kPa, p = 0.003). Improved oxygenation extended into the PACU with a lower incidence of postoperative hypoxemia (3.8% vs. 26.9%, p = 0.021). Additionally, PEEPIND was associated with lower driving pressures (12.0 ± 3.0 vs. 15.0 ± 4.4 cm H2O, p = 0.044) and better compliance (44.5 ± 12.8 vs. 33.6 ± 9.1 mL/cm H2O, p = 0.017). Our data indicated that individualized PEEP guided by EIT without intraoperative recruitment maneuvers also improved perioperative oxygenation in patients undergoing robot-assisted laparoscopic radical prostatectomy, which could benefit patients with the risk of intraoperative hemodynamic instability caused by recruitment maneuvers. Trial registration: China Clinical Trial Registration Center Identifier: ChiCTR2100053839. This study was registered on 1 December 2021. The first patient was recruited on 15 December 2021.

30 October 2024 in The Clinical Journal of Pain
Verified
Journal Article
Closed access
JXJianghui Xu
Jianghui Xu
DLDandan Ling
Dandan Ling
QXQianyun Xu
Qianyun Xu
PSPengfei Sun
Pengfei Sun
SWShiyou Wei
Shiyou Wei
JZJun Zhang
Jun Zhang
Objectives: The double-point serratus anterior plane block (SAPB) covers more area, including the axilla, than the single-point approach, potentially offering better pain relief after modified radical mastectomy (MRM). The objective of this study were to evaluate the clinical outcomes of these 2 procedures for patients treated with MRMs. Methods: Sixty women were randomly assigned to double- or single-point groups. Double-point received SAPB at the third and fifth ribs, single-point at the fifth rib. The primary outcome includes pain numeric rating scale (NRS) at rest and movement 24 hours postsurgery. The secondary outcomes are axilla comfort NRS, recovery quality, and adverse events. Results: At 24 hours postsurgery, the double-point group compared with the single-point group showed movement pain NRS of 3 (2 to 3) versus 3 (3 to 4) (P=0.011) and rest pain NRS of 1 (1 to 1) versus 2 (1 to 3) (P=0.037). The difference between them did not exceed the minimum clindically important difference (MCID). The axillary comfort NRS in the double-point group was lower than the single-point group at 6 and 12 hours postsurgery, at 1 (1 to 2) versus 2 (2 to 4) (P=0.001) and 1 (1 to 2) versus 2 (2 to 4) (P=0.01), respectively, but there were no statistically significant differences at 24 and 48 hours postsurgery. At 48 hours postsurgery, pain scores and opioid use were similar in both groups. Recovery scores, rescue analgesia timing, adverse events, and hospital stay length were similar in both groups. Discussion: Double-point SAPB offers wider anesthetic spread but shows no significant clinical advantage in pain or axillary comfort over single-point SAPB after MRM.

3 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
LGLing ling Gao
Ling ling Gao
LPLili Pan
Lili Pan
LYLi Yang
Li Yang
YCYu Cui
Yu Cui
JZJun Zhang
Jun Zhang
Background: The optimal intraoperative positive end-expiratory pressure (PEEP) obtained by titrating to the lowest tolerable fraction of inspired oxygen (FiO2) has been proposed recently; however, whether its performance in obtaining optimal PEEP is comparable to that from electrical impedance tomography (EIT) titration remains unknown. Methods: Ninety-three adult patients undergoing robotic-assisted laparoscopic prostatectomy under general anesthesia were enrolled in this study. They underwent the determination of optimal PEEP obtained either by titrating to the lowest tolerable FiO2 (PEEPO2) or using EIT (PEEPEIT). The primary endpoint was intraoperative optimal PEEP values. Secondary endpoints included pre-extubation arterial oxygen partial pressure (PaO2)/FiO2, intraoperative mean arterial blood pressure (MAP), the incidence of hypoxemia in the postanesthesia care unit (PACU), and postoperative pulmonary complications (PPCs) up to discharge from hospital. Results: Group PEEPO2 (n = 47) exhibited a higher optimal PEEP compared to Group PEEPEIT (n = 46) [Median (IQR): 18 (16–18 cmH2O) vs. 16 (14–16 cmH2O), p < 0.001]. Pre-extubation PaO2/FiO2 was higher in Group PEEPO2 (510.5 ± 80.0 vs. 471.8 ± 69.0 mmHg, p = 0.015), while lung dynamic compliance (41.1 ± 7.7 vs. 37.3 ± 6.4 mL cmH2O−1, p = 0.011) and static compliance (36.4 ± 5.8 vs. 33.6 ± 5.5 mL cmH2O−1, p = 0.017) were also higher in Group PEEPO2. Additionally, driving pressure (11.0 ± 2.0 vs. 12.1 ± 1.9 cmH2O, p = 0.006) was lower in Group PEEPO2. There were no significant differences in intraoperative MAP and the incidences of PACU hypoxemia and PPCs between the two groups. Conclusions: The optimal PEEP obtained by titrating to the lowest tolerable FiO2 is a clinically acceptable alternative of that obtained using EIT. Therefore, this technique could be a viable alternative to EIT for obtaining optimal PEEP.