Xiaodong Yang

Dr. Xiaodong Yang


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 April 2024 in Buildings
Verified
Journal Article
Open access
PDF file
SZSheng Zhu
Sheng Zhu
PWPing Wang
Ping Wang
WLWei Lou
Wei Lou
SSShilin Shen
Shilin Shen
TLTongtong Liu
Tongtong Liu
Xiaodong YangXiaodong Yang
Xiaodong Yang
Building-integrated flexible resources can offer economical availability to accommodate high-penetrated renewable energy sources (RESs), which can be potentially coordinated to achieve cost-effective supply. This paper proposes a resilience-oriented planning model of urban distribution system source–network–load–storage in the context of high-penetrated building-integrated resources. In this model, source–network–load–storage resources are cost-optimally planned, including the lines, soft open point (SOP), building-integrated photovoltaics (BIPVs), building-integrated wind turbine (BIWT), building-integrated energy storage system (ESS), etc. To enhance fault recovery capability during extreme faults, fault scenarios are incorporated into the distribution system operation via coupled multiple recovery stages. The resilience-oriented planning is a thorny problem due to its source–network–load–storage couplings, normal-fault couplings, etc. The original resilience-oriented planning is reformulated as a mixed-integer linear programming (MILP) problem, which can then be solved with a two-stage method and evaluated via a multi-dimensional evaluation metrics. The proposed planning methodology is benchmarked over a Portugal 54-node urban distribution system to verify the superiority and effectiveness on the system economy and resilience levels. Case studies show that the proposed methodology can exploit the optimal synergies of different source–network–load–storage components and enhance system dispatchability.

20 December 2016 in Energies
Verified
Journal Article
Open access
PDF file
GWGuoqing Weng
Guoqing Weng
FHFeiteng Huang
Feiteng Huang
JYJun Yan
Jun Yan
Xiaodong YangXiaodong Yang
Xiaodong Yang
YZYoubing Zhang
Youbing Zhang
HHHaibo He
Haibo He
This paper proposed a fault-tolerant approach based on information fusion (IF) to automatically locate the transient voltage disturbance source (TVDS) in smart distribution grids. We first defined three credibility factors that will influence the reliability of the direction-judgments at each power quality monitor (PQM). Then we proposed two rules of influence and a verification factor for the distributed generation (DG) integration. Based on the two sets of direction-judgment criteria, a novel decision-making method with fault tolerance based on the IF theory is proposed for automatic location of the TVDS. Three critical schemes, including credibility fusion, conflict weakening, and correction for DG integration, have been integrated in the proposed fusion method, followed by a reliability evaluation of the location results. The proposed approach was validated on the IEEE 13-node test feeder, and the TVDS location results demonstrated the effectiveness and fault tolerance of the IF based approach.

7 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WLWei Lou
Wei Lou
SZShenglong Zhu
Shenglong Zhu
JDJinjin Ding
Jinjin Ding
TZTaiyun Zhu
Taiyun Zhu
MWMing Wang
Ming Wang
Xiaodong YangXiaodong Yang
Xiaodong Yang
Demand–response (DR) can provide the economic flexibility required to adapt a high proportion of renewable energy in the context of a smart grid. This paper proposes a transactive DR framework to enable the multi-time-scale proactive participation of demand-side flexible multi-energy resources. In this framework, the distribution system operator distributes the real-time DR request and the high renewable penetrated multi-energy prosumer aggregators provide the ancillary services based on their adjustable potential. To facilitate such multi-time-scale prosumer–operator interactions, a flexibility potential evaluation method is developed for the quantification and pricing of prosumer flexibility. The positive and negative flexibility potential of the demand-side prosumer aggregators are defined as deviations from the optimal pre-dispatch operation, which are further quantified using the aspects of flexible time and power. Based on the introduction of a flexibility pricing mechanism to identify the economically optimal ancillary service requirements, each prosumer aggregator performs an optimal real-time DR scheduling. Case studies over several DR schemes are performed to confirm the effectiveness and superiority of the proposed method on the economy and flexibility of the system.

3 February 2026 in Technologies
Verified
Journal Article
Open access
PDF file
Da XuDa Xu
Da Xu
Xiaodong YangXiaodong Yang
Xiaodong Yang
JWJuan Wei
Juan Wei
XZXiaoshun Zhang
Xiaoshun Zhang
The past years have seen a progressive process of urbanization and upgrading, along with the intelligentialization and popularity of supply-demand sides through advanced information and communication technologies

12 March 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Da XuDa Xu
Da Xu
YYYuanhang Yang
Yuanhang Yang
Chi-Seng LamChi-Seng Lam
Chi-Seng Lam
Sunhua HuangSunhua Huang
Sunhua Huang
Xiaodong YangXiaodong Yang
Xiaodong Yang
HLHaoyu Li
Haoyu Li
The coordination of power system and power electronics-enabled devices can cost-effectively enhance the system transient performance. This paper proposes an advanced nonlinear control method for the coordination of power systems with capacitive-coupled static synchronous compensator (STATCOM). In this method, multiple error surfaces of the time-domain system are constructed based on low-pass filter to avoid the inherent differential explosion of backstepping design. Such dynamic surface control is further combined with fixed-time/preassigned-time control to ensure the expected transient response. Lyapunov function is designed to resolve the closed-loop dynamics of power systems with capacitive-coupled STATCOM. It is proved that the proposed advanced nonlinear control method can ensure the semi-globally fixed-timely uniformly ultimately bounded (SFUUB) within estimable settling time. Case studies on a classical power system are implemented to show its effective and superior transient performances.