Moritz Graf

Mr. Moritz Graf


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
KWKlaus Weraneck
Klaus Weraneck
FHFlorian Heilmeier
Florian Heilmeier
MLMarkus Lindner
Markus Lindner
MGMoritz Graf
Moritz Graf
MJMartin Jakobi
Martin Jakobi
AKAlexander W. Koch
Alexander W. Koch
In recent years, the observation of the behaviour of components during the production process and over their life cycle is of increasing importance. Structural health monitoring, for example of carbon composites, is state-of-the-art research. The usage of Fibre Bragg Gratings (FBGs) in this field is of major advantage. Another possible area of application is in foundries. The internal state of melts during the solidification process is of particular interest. By using embedded FBGs, temperature and stress can be monitored during the process. In this work, FBGs were embedded in aluminium alloys in order to observe the occurring strain. Two different FBG positions were chosen in the mould in order to compare its dependence. It was shown that FBGs can withstand the solidification process, although a compression in the range of one percent was measured, which is in agreement with the literature value. Furthermore, different lengths of the gratings were applied, and it was shown that shorter gratings result in more accurate measurements. The obtained results prove that FBGs are applicable as sensors for temperatures up to 740 °C.

1 September 2018 in TM - Technisches Messen
Verified
Journal Article
Closed access
PDF file
MGMoritz Graf
Moritz Graf
FEFabian Ehmer
Fabian Ehmer
CEChristoph Eisermann
Christoph Eisermann
MJMartin Jakobi
Martin Jakobi
AKAlexander W. Koch
Alexander W. Koch
ZusammenfassungIn diesem Beitrag wird ein neuartiger Ansatz zur Schadensdetektion in Stromversorgungskabeln vorgestellt. Die Funktionalität des Messsystems kann bezüglich des durch Makrobiegungen induzierten Anstiegs des Dämpfungsbelags verifiziert werden. Durch den verwendeten Integrationsansatz sind Mantelschäden im Stromversorgungskabel detektierbar, wodurch langfristige Ausfallgründe frühzeitig erkannt werden. Über eine integrierte optische Faser und ein optisches Zeitbereichsreflektometer kann unabhängig von der elektrischen Energieübertragung im Kabel eine exakte und effiziente Schadenslokalisierung sichergestellt werden, was wiederum eine Zeit- und Kostenersparnis zur Folge hat.