The increased penetration of distributed generation (DG), renewable energy utilization, and the introduction of the microgrid concept have changed the shape of conventional electric power networks. Most of the new power system networks are transforming into the DG model integrated with renewable and non-renewable energy resources by forming a microgrid. Islanding detection in DG systems is a challenging issue that causes several protection and safety problems. A microgrid operates in the grid-connected or stand-alone mode. In the grid-connected mode, the main utility network is responsible for a smooth operation in coordination with the protection and control units, while in the stand-alone mode, the microgrid operates as an independent power island that is electrically separated from the main utility network. Fast islanding detection is, therefore, necessary for efficient and reliable microgrid operations. Many islanding detection methods (IdMs) are proposed in the literature, and each of them claims better reliability and high accuracy. This study describes a comprehensive review of various IdMs in terms of their merits, viability, effectiveness, and feasibility. The IdMs are extensively analysed by providing a fair comparison from different aspects. Moreover, a fair analysis of a feasible and economical solution in view of the recent research trend is presented.
27 November 2017 in IET Generation, Transmission & Distribution
Islanding detection in power systems poses a challenge that can result in technical problems and safety hazards. This study examines a new passive islanding detection method for photovoltaic‐based distributed generation (DG) units. The modal signal of the three‐phase current and its envelope are calculated for a targeted DG unit. Variance in the autocorrelation of the modal current envelope (VAMCE) is used as an islanding detection criterion in the proposed method. The proposed method employs autocorrelation function (ACF) of modal current envelope (derived by Hilbert‐transform‐based approach) to extract the transient content. Then, the variance of the ACF is calculated, called criterion VAMCE to distinguish between islanded and normal operating conditions. The main advantage of the proposed technique is more relevant to its more accuracy and smaller non‐detection zone in comparison with the other similar passive techniques. Since the VAMCE has significant variation during islanding conditions and negligible change in normal conditions, it can be used for detection of islanding condition effectively. The method was evaluated through several simulations under different islanded and normal operating conditions. The results confirm that the proposed method has better accuracy and speed compared to other similar methods.
1 March 2019 in International Journal of Electrical Power & Energy Systems
The modern electric power system is foreseen to have increased penetration of controllable loads under demand response programs and renewable energy resources coupled with energy storage systems which can provide virtual inertia. In this paper, the conventional model of an electric power system is appended by considering, individually and collaboratively, the role of demand response and virtual inertia for the purpose of frequency analysis and control. Most existing literature on this topic either considers one of these two roles or lacks in providing a general model of power system with demand response and virtual inertia. The proposed model is presented in general form and can include/exclude demand response and/or virtual inertia. Further, power system operator can opt the power shares from conventional, demand response, and virtual inertia loops for frequency regulation and can also evaluate the impact of other parameters such as time delays and frequency deadbands on system frequency response. The mathematical formulation of steady-state values of frequency deviation and power contribution from all resources is provided and validated by simulation results under various scenarios including a case of wind intermittency.
14 August 2019 in Journal of Electrical Engineering & Technology
In recent decades, the power grid’s configuration is shifting towards a smart grid where responsive loads and energy storage systems (ESS) are finding an increased role in the power system operation. In the presented work, a mathematical formulation for frequency response analysis of a multi-machine power system is developed, considering the individual and combined roles of ESS and responsive loads. The validity of the developed model is demonstrated with the help of multiple case studies, which consider the various configurations of the power system. Moreover, different combinations of capacities of generation units, ESS and responsive loads are also simulated. With the help of mathematical model and simulation results, it is demonstrated that ESS and responsive loads may improve the economy and performance of the power system even during the failure of a certain portion of generation capacity. Though the case studies consider non-reheat turbines only, the mathematical model and conclusions are equally valid for other types of turbines as well.