This review paper presents an overview of depth cameras. Our goal is to describe the features and capabilities of the introduced depth sensors in order to determine their possibilities in robotic applications, focusing on objects that might appear in applications with high accuracy requirements. A series of experiments was conducted, and various depth measuring conditions were examined in order to compare the measurement results of all the depth cameras. Based on the results, all the examined depth sensors were appropriate for applications where obstacle avoidance and robot spatial orientation were required in coexistence with image vision algorithms. In robotic vision applications where high accuracy and precision were obligatory, the ZED depth sensors achieved better measurement results.
Accurate and reliable measurement of the electrical impedance spectrum is an essential requirement in order to draw relevant conclusions in many fields and a variety of applications; in particular, for biological processes. Even in the state-of-the-art methods developed for this purpose, the accuracy and efficacy of impedance measurements are reduced in biological systems, due to the regular occurrence of parameters causing measurement errors such as residual impedance, parasitic capacitance, generator anomalies, and so on. Recent observations have reported the necessity of decreasing such inaccuracies whenever measurements are performed in the ultra-low frequency range, as the above-mentioned errors are almost entirely absent in such cases. The current research work proposes a method which can reject the anomalies listed above when measuring in the ultra-low frequency range, facilitating data collection at the same time. To demonstrate our hypothesis, originating from the consideration of the determinant role of the measuring frequency, a physical model is proposed to examine the effectiveness of our method by measuring across the commonly used vs. ultra-low frequency ranges. Validation measurements reflect that the range of frequencies and the accuracy is much greater than in state-of-the-art methods. Using the proposed new impedance examination technique, biological system characterization can be carried out more accurately.
The utilization of stereo cameras in robotic applications is presented in this paper. The use of a stereo depth sensor is a principal step in robotics applications, since it is the first step in sequences of robotic actions where the intent is to detect and extract windows and obstacles that are not meant to be painted from the surrounding wall. A RealSense D435 stereo camera was used for surface recording via a real-time, appearance-based (RTAB) mapping procedure, as well as to navigate the painting robot. Later, wall detection and the obstacle avoidance processes were performed using statistical filtering and a random sample consensus model (RANSAC) algorithm.
This paper presents a comprehensive analysis of the dead-time effects in wireless power transfer systems based on LCC-S topology. In these systems operating at high frequencies, the ratio of dead-time versus the operating period becomes critical, and the dead-time issue can cause certain problems regarding power quality, efficiency, and output voltage ripple. The impact of input quantities such as voltage and switching frequency on the efficiency and output power of the LCC-S-tuned WPT system was also investigated. The optimal combination of these parameters used to achieve the maximum efficiency for a target output power and to set the appropriate value of the dead time were determined by running multiple simulations using the MATLAB R2023b software platform. It was also shown that the output voltage remained unchanged with and without a load and up to 1200 ns of dead-time, which provides a simple implementation of the corresponding mathematical model. In the recommended interval of 600–1500 ns, the influence of the dead-time on the value of the output voltage amplitude is less than 10%. The validity of the proposed method was confirmed through the implementation of the experimental prototype, a 5 kW wireless power transmission system, and the obtained results were in accordance with the simulation results.
Dynamic random dot stereograms (DRDSs) and correlograms (DRDCs) are cyclopean stimuli containing binocular depth cues that are ideally, invisible by one eye alone. Thus, they are important tools in assessing stereoscopic function in experimental or ophthalmological diagnostic settings. However, widely used filter-based three-dimensional display technologies often cannot guarantee complete separation of the images intended for the two eyes. Without proper calibration, this may result in unwanted monocular cues in DRDSs and DRDCs, which may bias scientific or diagnostic results. Here, we use a simple mathematical model describing the relationship of digital video values and average luminance and dot contrast in the two eyes. We present an optimization algorithm that provides the set of digital video values that achieve minimal crosstalk at user-defined average luminance and dot contrast for both eyes based on photometric characteristics of a given display. We demonstrated in a psychophysical experiment with color normal participants that this solution is optimal because monocular cues were not detectable at either the calculated or the experimentally measured optima. We also explored the error by which a range of luminance and contrast combinations can be implemented. Although we used a specific monitor and red-green glasses as an example, our method can be easily applied for other filter based three-dimensional systems. This approach is useful for designing psychophysical experiments using cyclopean stimuli for a specific display.
Based on a prior university patent, the authors developed a novel type of bioimpedance-based test method to noninvasively detect nonalcoholic fatty liver disease (NAFLD). The development of a new potential NAFLD diagnostic procedure may help to understand the underlying mechanisms between NAFLD and severe liver diseases with a painless and easy-to-use paraclinical examination method, including the additional function to detect even the earlier stages of liver disease. The aim of this study is to present new results and the experiences gathered in relation to NAFLD progress during animal model and human clinical trials.