Invasive ductal carcinoma (IDC) in breast specimens has been detected in the quadrant breast area: (I) upper outer, (II) upper inner, (III) lower inner, and (IV) lower outer areas by electrical impedance tomography implemented with Gaussian relaxation-time distribution (EIT-GRTD). The EIT-GRTD consists of two steps which are (1) the optimum frequency selection and (2) the time constant enhancement of breast imaging reconstruction. is characterized by a peak in the majority measurement pair of the relaxation-time distribution function which indicates the presence of IDC. γ represents the inverse of conductivity and indicates the response of breast tissues to electrical currents across varying frequencies based on the Voigt circuit model. The EIT-GRTD is quantitatively evaluated by multi-physics simulations using a hemisphere container of mimic breast, consisting of IDC and adipose tissues as normal breast tissue under one condition with known IDC in quadrant breast area II. The simulation results show that EIT-GRTD is able to detect the IDC in four layers at = 30, 170 Hz. EIT-GRTD is applied in the real breast by employed six mastectomy specimens from IDC patients. The placement of the mastectomy specimens in a hemisphere container is an important factor in the success of quadrant breast area reconstruction. In order to perform the evaluation, EIT-GRTD reconstruction images are compared to the CT scan images. The experimental results demonstrate that EIS-GRTD exhibits proficiency in the detection of the IDC in quadrant breast areas while compared qualitatively to CT scan images.
15 February 2024 in IEEE Transactions on Instrumentation and Measurement
Sodium-ion concentration c in the dermis layer has been extracted by time-constant-domain electrical impedance spectroscopy (TCD-EIS) with the dermis separation model (DSM). The TCD-EIS with DSM consists of the dermis separation formulation, ridge regression optimization, and distribution relaxation times (DRT) with radial base function. To distinguish the relaxation time of the dermis τ d from the other layers (stratum corneum τ sc , the epidermis τ e , and the fat layer τ f ), the subtracted impedivity was calculated by distant electrode pair z 1 , and close the electrode pair z 2 , based on optimum electrode diameter ϕ and distance l . The numerical optimizations were implemented to optimize ϕ from 0.5 to 3 mm and l from 2 to 8 mm, regarded as DSM sensor parameters. In the simulation, the optimized DSM sensor parameters, ϕ*=1 mm and l *=1 mm, were applied to the skin model under the condition of 1) various sodium-ion concentrations c in the dermis layer, 2) frequencies f from 100 Hz to 1 MHz. In the experiments, the optimized TCD-EIS with DSM was applied to porcine skin under the condition following the simulations. The relation between the distribution function γ and relaxation times τ, were used to evaluate the sodium-ion concentration extraction. Both simulation and experiment results show that the normalized distribution function of the dermis γ* c (ln τ d )decreases with the increase of sodium-ion concentration c . The sodium-ion concentration c in the dermis layer was distinguished properly at dermis relaxation times τ d =10 -2 [s]. TCD-EIS with DSM reveals that the decrease of a normalized distribution function γ* c (ln τ d ), correlates with the increased sodium-ion concentration c injected in the dermis layer.
The minor copper (Cu) particles among major aluminum (Al) particles have been detected by means of an integration of a generative adversarial network and electrical impedance tomography (GAN-EIT) for a wet-type gravity vibration separator (WGS). This study solves the problem of blurred EIT reconstructed images by proposing a GAN-EIT integration system for Cu detection in WGS. GAN-EIT produces two types of images of various Cu positions among major Al particles, which are (1) the photo-based GAN-EIT images, where blurred EIT reconstructed images are enhanced by GAN based on a full set of photo images, and (2) the simulation-based GAN-EIT images. The proposed metal particle detection by GAN-EIT is applied in experiments under static conditions to investigate the performance of the metal detection method under single-layer conditions with the variation of the position of Cu particles. As a quantitative result, the images of detected Cu by GAN-EIT in different positions have higher accuracy as compared to . In the region of interest (ROI) covered by the developed linear sensor, GAN-EIT successfully reduces the Cu detection error of conventional EIT by 40% while maintaining a minimum signal-to-noise ratio (SNR) of 60 [dB]. In conclusion, GAN-EIT is capable of improving the detailed features of the reconstructed images to visualize the detected Cu effectively.
27 July 2023 in Biomedical Physics & Engineering Express
Free and bound sodium in human skin models have been identified by two proposals: skin’s phantom fabrication and skin’s dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS). The spa-BIS consist of conductivity-permittivity separation, contact impedance compensation, and a correlation score algorithm based on the vessel with a bipolar electrode. The skin phantom fabrication comprises a recipe combination with temperature-controlled protocol and sodium molarity calculation. In experiments, the human skin models are created to mimic the electrical properties of skin under with several different sodium molarities. Based on five types of human skin models with five samples of each group, the free sodium type conductivity and concentration results following a linear trendline of concentration change in skin tissues theorems with the fRequency range from to while the bound sodium type results The spa-BIS compensate of vessel contact impedance. The dielectric properties of each type have been extracted with less than 10% of the average standard deviation, which is considered an accurate identification method of dermis dielectric properties. The algorithm successfully identifies sodium type: free sodium has a negative, and bound sodium has a positive correlation score trend. As an additional discussion, the different time-dependent effects, the different water content, and different agar content analyses have been provided in this study. As a robust analysis method, the spa-BIS has a prominent performance to replace a 23Na-MRI in terms of free and bound sodium identification.
19 September 2024 in Biomedical Physics & Engineering Express
Breast cancer detection and differentiation of breast tissues are critical for accurate diagnosis and treatment planning. This study addresses the challenge of distinguishing between invasive ductal carcinoma (IDC), normal glandular breast tissues (nGBT), and adipose tissue using electrical impedance spectroscopy combined with Gaussian relaxation-time distribution (EIS-GRTD). The primary objective is to investigate the relaxation-time characteristics of these tissues and their potential to differentiate between normal and abnormal breast tissues. We applied a single-point EIS-GRTD measurement to ten mastectomy specimens across a frequency range f = 4 Hz to 5 MHz. The method calculates the differential ratio of the relaxation-time distribution function between IDC and nGBT, which is denoted by and between IDC and adipose tissues, which is denoted by As a result, the differential ratio of between IDC and nGBT is 0.36, and between IDC and adipose is 0.27, which included in the -dispersion at In all specimens, the relaxation-time distribution function of IDC is higher, and there is no intersection with of nGBT and adipose The difference in suggests potential variations in relaxation properties at the molecular or structural level within each breast tissue that contribute to the overall relaxation response. The average mean percentage error for IDC, nGBT, and adipose tissues are 5.90%, 6.33%, and 8.07%, respectively, demonstrating the model’s accuracy and reliability. This study provides novel insights into the use of relaxation-time characteristic for differentiating breast tissue types, offering potential advancements in diagnosis methods. Future research will focus on correlating EIS-GRTD finding with pathological results from the same test sites to further validate the method’s efficacy.
Area of breast cancer tissues has been clustered by newly-proposed electrical impedance tomography (EIT) implemented with Poisson and Gaussian mixture models (EIT-PGMM) for breast cancer identification. EIT-PGMM comprises two distinct methods for comparison: EIT-PMM (Poisson Mixture Model) and EIT-GMM (Gaussian Mixture Model). EIT-PGMM consists of two sections which are 1) reconstruction section by EIT to reconstruct conductivity distribution σ ∈R
(
F
×
N
)
( f : frequency 1≤ f ≤ F , n : area resolution 1≤ n ≤ N ) from impedance distribution Z ∈C
(
F
×
M
)
( f : frequency 1≤ f ≤ F , m : measurement number 1≤ m ≤ M ) on injection current i between electrodes on measurement boundary and measurement voltages v , and 2) clustering section by PGMM to cluster breast cancer area B with cluster assignment (one-hot vector) s ∈R
(
N
×
K
)
( k : cluster number 1≤ k ≤ K ) to sharpen the border between cancerous and normal breast tissues. The s is probabilistically determined through posterior p ( s|σ,Θ ) ( Θ : parameters of Poisson and Gaussian mixture models) assigns each spatial resolution to a specific cluster, which highest mean conductivity distribution 〈 σk 〉 among the K clusters is identified as the breast cancer region B . The EIT-PGMM was applied to the mastectomized breast tissues from 5 patients placed inside hemispherical sensor of EIT under the condition of injection current frequencies f ranging from 1 [kHz] to 3 [MHz]. Qualitatively, breast cancer region B remains similar across different values of K and between EIT-PMM and EIT-GMM. In order to quantitatively evaluate B , the results of EIT-PMM and EIT-GMM were compared with the diameter D measured clinically and area A of breast cancer segmented from the coronal plane of CT scan. EIT-GMM provides a more accurate estimation of breast cancer region B with accuracy of 90.2% in diameter DKGMM . and 79.3% in area AKGMM .