Kunti Khoirunnisaa

Kunti Khoirunnisaa

Auto-generated profile, based on publicly available information

Kunti Khoirunnisaa

Department of Mechanical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
KKKunti Khoirunnisaa
Kunti Khoirunnisaa
Kiagus Aufa IbrahimKiagus Aufa Ibrahim
Kiagus Aufa Ibrahim
HYHiroto Yamamoto
Hiroto Yamamoto
HFHiroshi Fujimoto
Hiroshi Fujimoto
JIJun-Ichiro Ikeda
Jun-Ichiro Ikeda
MTMasahiro Takei
Masahiro Takei
Area of breast cancer tissues has been clustered by newly-proposed electrical impedance tomography (EIT) implemented with Poisson and Gaussian mixture models (EIT-PGMM) for breast cancer identification. EIT-PGMM comprises two distinct methods for comparison: EIT-PMM (Poisson Mixture Model) and EIT-GMM (Gaussian Mixture Model). EIT-PGMM consists of two sections which are 1) reconstruction section by EIT to reconstruct conductivity distribution σ ∈R ( F × N ) ( f : frequency 1≤ f ≤ F , n : area resolution 1≤ n ≤ N ) from impedance distribution Z ∈C ( F × M ) ( f : frequency 1≤ f ≤ F , m : measurement number 1≤ m ≤ M ) on injection current i between electrodes on measurement boundary and measurement voltages v , and 2) clustering section by PGMM to cluster breast cancer area B with cluster assignment (one-hot vector) s ∈R ( N × K ) ( k : cluster number 1≤ k ≤ K ) to sharpen the border between cancerous and normal breast tissues. The s is probabilistically determined through posterior p ( s|σ,Θ ) ( Θ : parameters of Poisson and Gaussian mixture models) assigns each spatial resolution to a specific cluster, which highest mean conductivity distribution 〈 σ k 〉 among the K clusters is identified as the breast cancer region B . The EIT-PGMM was applied to the mastectomized breast tissues from 5 patients placed inside hemispherical sensor of EIT under the condition of injection current frequencies f ranging from 1 [kHz] to 3 [MHz]. Qualitatively, breast cancer region B remains similar across different values of K and between EIT-PMM and EIT-GMM. In order to quantitatively evaluate B , the results of EIT-PMM and EIT-GMM were compared with the diameter D measured clinically and area A of breast cancer segmented from the coronal plane of CT scan. EIT-GMM provides a more accurate estimation of breast cancer region B with accuracy of 90.2% in diameter D K GMM . and 79.3% in area A K GMM .