Joerg Schotter

Dr. Joerg Schotter

Austrian Institute of Technology GmbH, Molecular Diagnostics, Giefinggasse 4, 1210 Vienna, Austria

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SSStefan Schrittwieser
Stefan Schrittwieser
BPBeatriz Pelaz
Beatriz Pelaz
WPWolfgang Parak
Wolfgang Parak
SLSergio Lentijo-Mozo
Sergio Lentijo-Mozo
KSKaterina Soulantica
Katerina Soulantica
JSJoerg Schotter
Joerg Schotter
The growing availability of biomarker panels for molecular diagnostics is leading to an increasing need for fast and sensitive biosensing technologies that are applicable to point-of-care testing. In that regard, homogeneous measurement principles are especially relevant as they usually do not require extensive sample preparation procedures, thus reducing the total analysis time and maximizing ease-of-use. In this review, we focus on homogeneous biosensors for the in vitro detection of biomarkers. Within this broad range of biosensors, we concentrate on methods that apply magnetic particle labels. The advantage of such methods lies in the added possibility to manipulate the particle labels by applied magnetic fields, which can be exploited, for example, to decrease incubation times or to enhance the signal-to-noise-ratio of the measurement signal by applying frequency-selective detection. In our review, we discriminate the corresponding methods based on the nature of the acquired measurement signal, which can either be based on magnetic or optical detection. The underlying measurement principles of the different techniques are discussed, and biosensing examples for all techniques are reported, thereby demonstrating the broad applicability of homogeneous in vitro biosensing based on magnetic particle label actuation.

28 December 2017 in Materials
Verified
Journal Article
Open access
PDF file
SSStefan Schrittwieser
Stefan Schrittwieser
DRDaniela Reichinger
Daniela Reichinger
JSJoerg Schotter
Joerg Schotter
The growing number of nanoparticle applications in science and industry is leading to increasingly complex nanostructures that fulfill certain tasks in a specific environment. Nickel nanorods already possess promising properties due to their magnetic behavior and their elongated shape. The relevance of this kind of nanorod in a complex measurement setting can be further improved by suitable surface modification and functionalization procedures, so that customized nanostructures for a specific application become available. In this review, we focus on nickel nanorods that are synthesized by electrodeposition into porous templates, as this is the most common type of nickel nanorod fabrication method. Moreover, it is a facile synthesis approach that can be easily established in a laboratory environment. Firstly, we will discuss possible applications of nickel nanorods ranging from data storage to catalysis, biosensing and cancer treatment. Secondly, we will focus on nickel nanorod surface modification strategies, which represent a crucial step for the successful application of nanorods in all medical and biological settings. Here, the immobilization of antibodies or peptides onto the nanorod surface adds another functionality in order to yield highly promising nanostructures.

16 December 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SSStefan Schrittwieser
Stefan Schrittwieser
MHMichael Johannes Haslinger
Michael Johannes Haslinger
TMTina Mitteramskogler
Tina Mitteramskogler
Michael M. MühlbergerMichael M. Mühlberger
Michael M. Mühlberger
ASAstrit Shoshi
Astrit Shoshi
JSJoerg Schotter
Joerg Schotter
Nanostructured surfaces and nanoparticles are already widely employed in many different fields of research, and there is an ever-growing demand for reliable, reproducible and scalable nanofabrication methods. This is especially valid for multifunctional nanomaterials with physical properties that are tailored for specific applications. Here, we report on the fabrication of two types of nanomaterials. Specifically, we present surfaces comprising a highly uniform array of elliptical pillars as well as nanoparticles with the shape of nanopockets, possessing nano-cavities. The structures are fabricated by nanoimprint lithography, physical and wet-chemical etching and sputter deposition of thin films of various materials to achieve a multifunctional nanomaterial with defined optical and magnetic properties. We show that the nanopockets can be transferred to solution, yielding a nanoparticle dispersion. All fabrication steps are carefully characterized by microscopic and optical methods. Additionally, we show optical simulation results that are in good agreement with the experimentally obtained data. Thus, this versatile method allows to fabricate nanomaterials with specific tailor-made physical properties that can be designed by modelling prior to the actual fabrication process. Finally, we discuss possible application areas of these nanomaterials, which range from biology and medicine to electronics, photovoltaics and photocatalysis.

18 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
EMEva Melnik
Eva Melnik
IMIris Muschlin
Iris Muschlin
AWAgnes Wildauer
Agnes Wildauer
MRMirco Raskovic
Mirco Raskovic
JSJoerg Schotter
Joerg Schotter
RHRainer Hainberger
Rainer Hainberger
Results are presented regarding the development of recycled paper based impedance biosensors with screen printed interdigitated electrode structures (IDES). The sensors show a response to increasing salt concentrations in the range 30–100 mM NaCl. To prove the feasibility of using recycled paper, biofunctionalization with a glucose sensitive enzyme mixture was performed by inkjet printing. The quantification of the glucose sensitive colour change reaction in paper was investigated and a trend is found in the range of 6–90 mg/dL. Subsequently, measurements with a wireless electronic readout system were performed on an electrochemical assay showing a decrease of the normalized sensor response dependent from the glucose concentration in the range 0–80 mg/dL.

21 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
RHRudolf Heer
Rudolf Heer
SKSigurd Krieger
Sigurd Krieger
SGSilvana Geleff
Silvana Geleff
JSJoerg Schotter
Joerg Schotter
WWWenze Wu
Wenze Wu
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
In this work we studied the influence of light emitting diode (LED) generated light on living cells which were cultivated in common cell culture microtiter plates. In detail we investigated signaling side effects including apoptosis by the use of a cell permeable peroxide activatable fluorescent dye (5,6-Chloromethyl-2′,7′-dichlorodihydrofluorescein diacetate). A high level production of peroxides in UV and blue light exposed cells was measured while the light of longer wavelengths caused only minor effects on the cells.