Gas leak detection is an important issue in infrastructure monitoring and industrial production. In this context, infrared (IR) absorption spectroscopy is a major measurement method. It can be applied in an extractive or remote detection scheme. Tunable laser spectroscopy (TLS) instruments are able to detect CH4 leaks with column densities below 10 ppm·m from a distance of 30 m in less than a second. However, leak detection of non-IR absorbing gases such as N2 is not possible in this manner. Due to the fact that any leaking gas displaces or dilutes the surrounding background gas, an indirect detection is still possible. It is shown by sensitive TLS measurements of the ambient background concentration of O2 that N2 leaks can be localized with extractive and standoff methods for distances below 1 m. Minimum leak rates of 0.1 mbar·L/s were determined. Flow simulations confirm that the leakage gas typically effuses in a narrow jet. The sensitivity is mainly determined by ambient flow conditions. Compared to TLS detection of CH4 at 1651 nm, the indirect method using O2 at 761 nm is experimentally found to be less sensitive by a factor of 100. However, the well-established TLS of O2 may become a universal tool for rapid leakage screening of vessels that contain unknown or inexpensive gases, such as N2.
Tunable laser spectroscopy (TLS) with infrared (IR) imaging is a powerful tool for gas leak detection. This study focuses on direct absorption spectroscopy (DAS) that utilizes wavelength modulation to extract gas information. A tunable interband cascade laser (ICL) with an optical power of 5 mW is periodically modulated by a sawtooth injection current at 10 Hz across the methane absorption around 3271 nm. A fast and sensitive thermal imaging camera for the mid-infrared range between 3 and 5.7 µm is operated at a frame rate of 470 Hz. Offline processing of image stacks is performed using different algorithms (DAS-F, DAS-f and DAS-2f) based on the Lambert–Beer law and the HITRAN database. These algorithms analyze various features of gas absorption, such as area (F), peak (f) and second derivative (2f) of the absorbance. The methane concentration in ppm*m is determined on a pixel-by-pixel analysis without calibration. Leak localization for methane leak rates as low as 0.25 mL/min is accurately displayed in a single concentration image with pixelwise sensitivities of approximately 1 ppm*m in a laboratory environment. Concentration image sequences represent the spatiotemporal dynamics of a gas plume with high contrast. The DAS-2f concept demonstrates promising characteristics, including accuracy, precision, 1/f noise rejection, simplicity and computational efficiency, expanding the applications of DAS.
Zusammenfassung: Für die Ferndetektion von Propan und Methan aus der Luft wurde ein drohnentaugliches Laserspektrometer entwickelt. Die Anwendung ist die Ortung von Gasleckagen und die Warnung vor explosiven Gas-Luft-Gemischen. Neuartig ist die Ferndetektion von Propan sowie die Vereinigung von Methan- und Propandetektion in einem Messsystem. Dies wird durch die Nutzung benachbarter Absorptionslinien von Methan und Propan im Spektralbereich bei 2.968 cm −1 erreicht. Als Messmethode wird die direkte Absorptionsspektroskopie mit einem abstimmbaren Interbandkaskadenlaser (ICL) als Lichtquelle genutzt. Mit einer vier Zoll (4″-) Empfangsoptik wird das rückgestreute Laserlicht aus einer Entfernung bis zu 15 m gesammelt und anschließend verarbeitet. Um eine Flugzeit der verwendeten Drohne von ca. 30 min zu ermöglichen, wurden eine leichte Optik, Elektronik und Mechanik entwickelt, sodass die Gesamtmasse des Messsystems unter 500 g liegt. Die Auflösung des Laserspektrometers für Propan und Methan unter Laborbedingungen ist jeweils kleiner als 1 ppm·m (1 σ ). Bei Feldtests auf einem Übungsgelände des Technischen Hilfswerkes konnte Methan von einer Drohne aus sicher und empfindlich gemessen werden. Während eines Überflugs über ein künstliches Leckszenario im Kellerschacht eines Hauses (Leckrate von 1 l/min, Überflug in ca. 3 m Höhe) konnte das Leck durch eine Methankonzentrationsmessung erfolgreich identifiziert werden. Die Auflösung (1 σ -Standardabweichung) war während des Überflugs kleiner als 7 ppm·m ohne bzw. außerhalb des direkten Einflusses der Leckage, während eine maximale Leckagekonzentration von 150 ppm·m über dem Leck bestimmt wurde.