Dongho Choi

Dr. Dongho Choi

School of Electronic and Electrical Engineering, Dankook University, Yongin, Gyeonggi-do, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DCDongho Choi
Dongho Choi
June-Seok LeeJune-Seok Lee
June-Seok Lee
YLYoung-Seol Lim
Young-Seol Lim
Kyo-Beum LeeKyo-Beum Lee
Kyo-Beum Lee
This article proposes a priority-based model predictive control (PMPC) method for a five-leg voltage source inverter (FLVSI) that independently drives dual three-phase induction motors (IMs). In a FLVSI operated by a MPC method, selecting an optimal future voltage vector among all 32 candidate switching states causes a high computational burden. However, by using the PMPC, low computation and current ripples can be achieved at the same time. In the PMPC method, two IMs are prioritized, and the priority of both IMs alternates every control period. For this property, the future voltage vector for the high-priority motor (HM) is selected first; that for the low-priority motor (LM) is selected next. In other words, whereas future switching states of both IMs are optimized by one cost function in the conventional MPCs, those of the HM and LM are optimized by their cost functions in PMPC. Therefore, HM and LM have eight and four candidate voltage vectors for cost minimization, respectively, which results in low computation complexity. Furthermore, current ripples are small because the HM is optimized based on all possible candidate voltage vectors, and both IMs are selected as the HM equally. The PMPC method is demonstrated by simulation and experiment results.

10 November 2007 in STRUCTURAL ENGINEERING AND MECHANICS
Verified
Journal Article
Closed access
DCDongho Choi
Dongho Choi
HYH. Yoo
H. Yoo
JSJ.I. Shin
J.I. Shin
SPS.I. Park
S.I. Park
KNK. Nogami
K. Nogami

29 July 2024 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
DCDongho Choi
Dongho Choi
JPJin-Hyuk Park
Jin-Hyuk Park
June-Seok LeeJune-Seok Lee
June-Seok Lee
This article proposes an individual module power control (IMPC) method for multi-separated winding (MSW)-solid-state transformer (SST) to realize multiport configuration in railway traction systems. In general, SST for railway traction systems features an input-series-output-parallel (ISOP) structure composed of cascaded H-bridge multilevel (CHB) converters and isolated DC-DC converters. This structure allows all rear stages, including the propulsion inverters, to be powered from a common DC output, necessitating additional DC-DC converters for interfacing with DC loads and batteries. Therefore, this article proposes the IMPC method for independently controlling module power in CHB, enabling multiport configuration. This approach allows direct connection of DC loads and batteries to SST modules without additional DC-DC converters while maintaining the characteristics of modularity. As a result, a small bulk and low construction cost can be achieved. To realize the IMPC method, the following steps were taken. First, the modulation method of CHB is suggested to synthesize the switching reference voltages individually considering the maximum power delivery. Second, the reactive current injection strategy is explained for full-range operation regardless of load conditions. Third, the linear modulation condition of IMPC is analyzed. Finally, the control block diagram implementing IMPC is presented. The validity of IMPC is demonstrated through experimental results.

2 July 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DCDongho Choi
Dongho Choi
JJJiho Ju
Jiho Ju
June-Seok LeeJune-Seok Lee
June-Seok Lee
This letter proposes an enhanced dead-time compensation method in cascaded H-bridge (CHB) inverters to mitigate current zero-crossing distortion (ZCD) by reflecting the ratio of current polarity. Typically, dead-time compensation involves adding an offset voltage, whose sign is determined by the current polarity, to the switching reference voltage. However, in digital signal processor (DSP)–based CHB systems, when the current polarity changes, offset voltages with an incorrect sign might be applied for the following reasons. First, due to the shadow register function in DSP, the offset voltage from previous samples is applied. Second, because the DSP only measures current at sampling points, if the current polarity changes within a control period (i.e., between sampling points), it cannot recognize the polarity change until the next sampling point. These two deteriorate current ZCD. Therefore, when the current polarity changes, the proposed method predicts the reference current of the next sample to prevent incorrect offset voltage caused by the shadow register. Furthermore, by using the reference currents of the present and predicted values, the current polarity ratio within a control period is reflected in the offset voltage; thus, mitigating current ZCD. The validity of the proposed dead-time compensation method is verified through experimental results conducted with a seven-level CHB inverter.

30 September 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ELEunWoo Lee
EunWoo Lee
DKDohyeon Kim
Dohyeon Kim
DCDongho Choi
Dongho Choi
June-Seok LeeJune-Seok Lee
June-Seok Lee
This paper proposes an extended discontinuous PWM (DPWM) method for the five-leg inverter (FLI) driving dual induction motors (IMs). Conventionally, a rotation carrier-based DPWM (RCB-DPWM) method has been proposed to increase the efficiency of FLI. This method reduces the switching loss of both motors similarly under the same conditions of speed and torque. However, RCB-DPWM method does not minimize the switching loss when the conditions differ. Therefore, this paper utilized the absolute value of the output currents to minimize the switching loss under different speed and torque conditions. Since the switching loss proportional to the magnitude of the output current, the offset voltage is calculated based on the current value. The offset voltage is added to the reference voltage and the modified reference voltage is clamped to 0.5 Vdc or -0.5 Vdc . As a result, the switching loss is minimized compared to the RCB-DPWM method under variable conditions, thereby maximizing the efficiency of the system by applying the proposed method. The performance of the proposed method is verified through the experimental results.

18 August 2025 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HOHyeon-Woo Oh
Hyeon-Woo Oh
DCDongho Choi
Dongho Choi
JBJeong-Yul Bang
Jeong-Yul Bang
June-Seok LeeJune-Seok Lee
June-Seok Lee
This paper proposes an open-circuit fault (OCF) diagnosis of single-phase cascaded H-bridge multilevel converter (CHB) with switching duty ratio-based estimated grid current. In general, the current is estimated based on the sampled values. This means that the switching state of each switch used for current estimation is represented as binary, either off (0) or on (1). However, when pulse width modulation (PWM) is used, the switching states can vary within the sampling period, leading to inaccuracies in both current estimation and fault diagnosis. To address this issue, the proposed method estimates the grid current by calculating the switching duty ratio of each switch during the sampling period, derived from carriers and voltage references. The fault switch is determined in three steps using only the grid current. First, the OCF is detected using the grid current in dq-axis synchronous reference frame. Subsequently, the fault switch pair is determined through the sign and magnitude of the residual between the estimated and sampled grid currents. Finally, the fault switch location is identified by comparing the magnitude of the residual with the reversely calculated residuals through the product of the dc-link voltages and the switching duty ratios. The validity of the proposed method is verified through the experimental results.