In high power motor drive systems, synchronized space vector pulsewidth modulation (synchronized SVPWM) is widely used to guarantee stable control performance. Synchronized SVPWM has a characteristic that the switching frequency varies abruptly when the pulse number transitions. This article proposes a pulse number transition point at which the phase difference is minimized to remove the phase difference of the sampling point that appears during synchronized SVPWM control. In addition, for a smooth pulse number transition of synchronized SVPWM, a compensation method for the magnitude and phase error of the inverter output voltage due to the time delay and a method of removing the existing phase difference without using a phase-locked loop are proposed in consideration of the characteristic of changing switching frequency. The validity and the implementation of the proposed method are verified by experimental results using a high-power inverter driving 332 kW interior permanent magnet synchronous motor (IPMSM).
30 September 2024 in IEEE Transactions on Industry Applications
This paper proposes an extended discontinuous PWM (DPWM) method for the five-leg inverter (FLI) driving dual induction motors (IMs). Conventionally, a rotation carrier-based DPWM (RCB-DPWM) method has been proposed to increase the efficiency of FLI. This method reduces the switching loss of both motors similarly under the same conditions of speed and torque. However, RCB-DPWM method does not minimize the switching loss when the conditions differ. Therefore, this paper utilized the absolute value of the output currents to minimize the switching loss under different speed and torque conditions. Since the switching loss proportional to the magnitude of the output current, the offset voltage is calculated based on the current value. The offset voltage is added to the reference voltage and the modified reference voltage is clamped to 0.5 Vdc or -0.5 Vdc . As a result, the switching loss is minimized compared to the RCB-DPWM method under variable conditions, thereby maximizing the efficiency of the system by applying the proposed method. The performance of the proposed method is verified through the experimental results.
21 August 2025 in IEEE Transactions on Transportation Electrification
Wound-field synchronous motors (WFSMs) allow control of the field current, resulting in numerous combinations of stator d–q axis current and field current capable of producing the same torque. In addition, changes in the d–q axis current and field current cause nonlinear variations in the inductance. This article proposes a method to control a WFSM using a current combination that outputs maximum torque with minimum copper losses while considering variations in the inductance. The proposed method controls the WFSM by creating a single lookup table (LUT) through experimentation, accounting for inductance variations due to changes in current while also reducing memory occupancy. In addition, since the LUT is created with current combinations that minimize copper losses, WFSM can be controlled with minimum copper losses. This article describes the method and sequence for creating the proposed single flux-torque LUT and verifies the proposed method through experimental results.
22 November 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In multi-motor driving systems, inverters with a reduced number of switches have been used to reduce costs and decrease volume and weight. This paper considers a three-phase four-leg inverter (FLI) to drive a dual-induction motor (IM). In this system, since one of the three-phase windings in each motor connects to the neutral point of the dc-link, neutral-point voltage fluctuation in the two dc-link capacitors occurs. The neutral-point voltage fluctuation, caused by common leg current, leads to voltage utilization reduction and unbalanced three-phase currents. Therefore, this paper proposes a method of minimizing the common leg current and it consists of phase difference compensation control during initial magnetization and torque current compensation control over the entire speed range. The phase difference compensation control maintains the electrical phase difference between two IMs as π during magnetization. Torque current compensation based on a PI controller eliminates neutral-point voltage fluctuation in the two dc-link capacitors at steady state. In addition, the proposed method is combined with an existing angle controller to maintain the electrical phase difference between two IMs as π and, with the slip controller, to synchronize the speed of the two IMs. The validity of the proposed method is verified by experimental results.
This paper proposes a full-speed range control method for an induction motor (IM) in railway systems using a hybrid-active neutral point clamped (HANPC) inverter. In railway systems, the demand for improving the efficiency of power semiconductors increases. Therefore, this paper proposes an IM control method for the railway system that utilizes an HANPC inverter to minimize switching losses and current harmonics. Additionally, this paper analyzes the control methods for different driving regions based on the motor’s speed, including neutral point voltage balancing compensation, indirect vector control, and field weakening control. Additionally, this paper utilizes synchronous pulse width modulation (PWM) methods to improve the railway system’s control performance. The proposed method’s validity and feasibility are verified through the experimental results using a high-power inverter driving a 390 kW IM.