EunWoo Lee

Mr. EunWoo Lee

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ELEunWoo Lee
EunWoo Lee
DKDohyeon Kim
Dohyeon Kim
DCDongho Choi
Dongho Choi
June-Seok LeeJune-Seok Lee
June-Seok Lee
This paper proposes an extended discontinuous PWM (DPWM) method for the five-leg inverter (FLI) driving dual induction motors (IMs). Conventionally, a rotation carrier-based DPWM (RCB-DPWM) method has been proposed to increase the efficiency of FLI. This method reduces the switching loss of both motors similarly under the same conditions of speed and torque. However, RCB-DPWM method does not minimize the switching loss when the conditions differ. Therefore, this paper utilized the absolute value of the output currents to minimize the switching loss under different speed and torque conditions. Since the switching loss proportional to the magnitude of the output current, the offset voltage is calculated based on the current value. The offset voltage is added to the reference voltage and the modified reference voltage is clamped to 0.5 Vdc or -0.5 Vdc . As a result, the switching loss is minimized compared to the RCB-DPWM method under variable conditions, thereby maximizing the efficiency of the system by applying the proposed method. The performance of the proposed method is verified through the experimental results.

16 July 2024 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
ELEunWoo Lee
EunWoo Lee
DCDongHo Choi
DongHo Choi
CLChang-Hee Lee
Chang-Hee Lee
June-Seok LeeJune-Seok Lee
June-Seok Lee

5 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ELEunWoo Lee
EunWoo Lee
JLJuyeon Lee
Juyeon Lee
June-Seok LeeJune-Seok Lee
June-Seok Lee
This paper proposes a reliable control strategy for dual induction motor drives using a five-leg inverter (FLI). Since the FLI has the structural characteristic where both motors share a common leg, the current of the common leg can flow at twice the magnitude of the other leg currents. To prevent this overcurrent, this paper proposes a reliable integrated control strategy for both normal and open-circuit fault conditions in the FLI. Under normal conditions, overcurrent can occur when the phase and frequency of the current for both motors are distinct; therefore, the angle controller and current limitation prevent overcurrent. In contrast, an open-circuit fault in the FLI can cause overcurrent due to altered current paths. To ensure a safe shutdown, identifying the specific location of the faulty switch is essential. Therefore, fault diagnosis is required using the stator currents. Once the fault is located, a fault-tolerant method is applied to safely stop the motors, considering both the fault location and the rated current of the common leg. Consequently, the proposed system enables reliable operation of dual induction motor drives under various conditions. The experimental results verify the effectiveness of the proposed system.