Stereotactic radiotherapy (SRT) plays a major role in treating brain metastases (BMs) and can be delivered using various equipment and techniques. This review aims to identify the dosimetric factors of each technique to determine whether one should be preferred over another for single BMs treatment. A systematic literature review on articles published between January 2015 and January 2022 was conducted using the MEDLINE and ScienceDirect databases, following the PRISMA methodology, using the keywords “dosimetric comparison” and “brain metastases”. The included articles compared two or more SRT techniques for treating single BM and considered at least two parameters among: conformity (CI), homogeneity (HI) and gradient (GI) indexes, delivery treatment time, and dose-volume of normal brain tissue. Eleven studies were analyzed. The heterogeneous lesions along with the different definitions of dosimetric indexes rendered the studied comparison almost unattainable. Gamma Knife (GK) and volumetric modulated arc therapy (VMAT) provide better CI and GI and ensure the sparing of healthy tissue. To conclude, it is crucial to optimize dosimetric indexes to minimize radiation exposure to healthy tissue, particularly in cases of reirradiation. Consequently, there is a need for future well-designed studies to establish guidelines for selecting the appropriate SRT technique based on the treated BMs’ characteristics.
1 February 2021 in Archives of Cardiovascular Diseases
MR-Linac is a recent device combining a linear accelerator with an MRI scanner. The improved soft tissue contrast of MR images is used for optimum delineation of tumors or organs at risk (OARs) and precise treatment delivery. Automatic segmentation of OARs can contribute to alleviating the time-consuming process for radiation oncologists and improving the accuracy of radiation delivery by providing faster, more consistent, and more accurate delineation of target structures and organs at risk. It can also help reduce inter-observer variability and improve the consistency of contouring while reducing the time required for treatment planning. In this work, state-of-the-art deep learning techniques were evaluated based on 2D and 2.5D training strategies to develop a comprehensive tool for the accurate segmentation of pelvic OARs dedicated to 0.35 T MR-Linac. In total, 103 cases with 0.35 T MR images of the pelvic region were investigated. Experts considered and contoured the bladder, rectum, and femoral heads as OARs and the prostate as the target volume. For the training of the neural network, 85 patients were randomly selected, and 18 were used for testing. Multiple U-Net-based architectures were considered, and the best model was compared using both 2D and 2.5D training strategies. The evaluation of the models was performed based on two metrics: the Dice similarity coefficient (DSC) and the Hausdorff distance (HD). In the 2D training strategy, Residual Attention U-Net (ResAttU-Net) had the highest scores among the other deep neural networks. Due to the additional contextual information, the configured 2.5D ResAttU-Net performed better. The overall DSC were 0.88 ± 0.09 and 0.86 ± 0.10, and the overall HD was 1.78 ± 3.02 mm and 5.90 ± 7.58 mm for 2.5D and 2D ResAttU-Net, respectively. The 2.5D ResAttU-Net provides accurate segmentation of OARs without affecting the computational cost. The developed end-to-end pipeline will be merged with the treatment planning system for in-time automatic segmentation.