shaojie Li

Mr. shaojie Li


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in Electronics
Verified
Journal Article
Open access
PDF file
ZSZhongqing Sang
Zhongqing Sang
SLshaojie Li
shaojie Li
YHYuanyuan Huang
Yuanyuan Huang
XGXin Gao
Xin Gao
RQRui Qiao
Rui Qiao
In the process of hardware-in-the-loop simulations (HILs) of indirect matrix converters (IMCs), solving the mathematical models of complex multiswitching converter topologies has become a major problem. The conventional approach is to split the complex mathematical model into multiple serial subsystems; however, this inevitably produces delays in the simulation steps between different subsystems, leading to numerical oscillations. In this paper, the method of latency-free decoupling is adopted, which has no time-step delay between different subsystems, making each subsystem a parallel operation. This can improve the numerical stability of the simulations and can effectively reduce the step size of the real-time simulation and alleviate the problem of real-time simulation resource consumption. In this paper, we discuss in detail the modeling process of IMC hardware-in-the-loop simulations with Finite Control Set Model Predictive Control (FCS-MPC), and experimentally validate our method using the Speedgoat test platform, resulting in a simulation step size of less than 200 ns. The simulation results are compared with the results of Matlab’s Simpower power system, which allows us to evaluate the accuracy of our model.

8 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
YYYimin You
Yimin You
RQRui Qiao
Rui Qiao
SLshaojie Li
shaojie Li
SZShunxiong Zhou
Shunxiong Zhou
SZShenjun Zhou
Shenjun Zhou
ZPZhenbo Peng
Zhenbo Peng
Since the insulation performance of air is not as good as that of SF6 and other gases, it is necessary to conduct an in-depth study on the insulation characteristics of the fuse tube in order to meet the requirements of normal breaking and to design a structural improvement scheme for a 12 kV environmental protection cabinet fuse tube that is suitable for using air as the insulating medium. In this study, the insulation performance of the fuse tube before improvement was studied, and the electric-field distribution of the 12 kV fuse tube placed in the air-insulated switchgear was analyzed. The results showed that the electric-field was heavily concentrated in the air gap of the fuse tube plug and around the ground rod. In this study, the structure of the fuse tube was specifically designed. By spraying conductive paint on the intersection surface of different media, equipotentiality was achieved, and a reasonable metal shielding structure was added to the site where the field intensity was concentrated so as to improve the distribution of the electric-field and avoid the breakdown caused by the concentration of field intensity. Through several improved designs, the maximum electric-field strength of the fuse tube of an environmental protection cabinet can be effectively reduced, and the insulation requirements of relevant standards can be met. A partial discharge test for the improved fuse tube was carried out, and the local discharge quantity of the improved fuse tube met the industry requirements, which verified the rationality of the fuse-tube-improvement scheme.

10 December 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
XGXin Gao
Xin Gao
YHYuanyuan Huang
Yuanyuan Huang
SLshaojie Li
shaojie Li
昌刘昌兴 刘
昌兴 刘
ZSZhongqing Sang
Zhongqing Sang
As a multi-switching power electronic circuit with complex variable topology, the three-level active neutral point clamped (ANPC) converter is a complex system with strong coupling and low linearity. It has numerous high-speed switching devices, a large number of switch states, and a high matrix dimension. Modeling each switch will undoubtedly further increase the circuit size. While in real-time simulation, updating all states of the model to produce outputs within a single time step results in a significant computational load, causing an increasing consumption of FPGA hardware resources as the number of switches and circuit size grow. In order to solve this problem, the current common practice is to decompose the entire complex power electronic system into smaller serial subsystems for modeling. The overall modeling approach for small circuits can be achieved, but when the size of the circuit increases, the overall modeling complexity and difficulty are increased or even impossible to achieve. Decoupling power electronic circuits with this decomposition into subsystem modeling not only reduces the matrix dimension and simplifies the modeling process, but also improves the computational efficiency of the real-time simulator. However, this inevitably generates simulation delays between different subsystems, leading to numerical oscillations. In an effort to overcome this challenge, this paper adopts the method of parallel computation after subsystem partitioning. There is no one-beat delay between different subsystems, and there is no loss of accuracy, which can improve the numerical stability of the modeling and can effectively reduce the step length of real-time simulation and alleviate the problem of real-time simulation resource consumption. In addition, to address the problems of low accuracy due to the traditional forward Euler method as a solver and the possibility of significant errors at some moments, this paper uses a modified prediction correction method to solve the discrete mathematical model, which provides higher accuracy as well as higher stability. And, different from the traditional control method, this paper uses an improved FCS-MPC strategy to control the switching transients of the ANPC model, which achieves a very good control effect. Finally, a simulation step size of less than 60 ns is successfully realized by empirical demonstration on the Speedgoat test platform. Meanwhile, the accuracy of our model can be objectively evaluated by comparing it with the simulation results of the Matlab Simpower system.